Accurate prediction of wall shear stress in a stented artery: newtonian versus non-newtonian models.

A significant amount of evidence linking wall shear stress to neointimal hyperplasia has been reported in the literature. As a result, numerical and experimental models have been created to study the influence of stent design on wall shear stress. Traditionally, blood has been assumed to behave as a Newtonian fluid, but recently that assumption has been challenged. The use of a linear model; however, can reduce computational cost, and allow the use of Newtonian fluids (e.g., glycerine and water) instead of a blood analog fluid in an experimental setup. Therefore, it is of interest whether a linear model can be used to accurately predict the wall shear stress caused by a non-Newtonian fluid such as blood within a stented arterial segment. The present work compares the resulting wall shear stress obtained using two linear and one nonlinear model under the same flow waveform. All numerical models are fully three-dimensional, transient, and incorporate a realistic stent geometry. It is shown that traditional linear models (based on blood's lowest viscosity limit, 3.5 Pa s) underestimate the wall shear stress within a stented arterial segment, which can lead to an overestimation of the risk of restenosis. The second linear model, which uses a characteristic viscosity (based on an average strain rate, 4.7 Pa s), results in higher wall shear stress levels, but which are still substantially below those of the nonlinear model. It is therefore shown that nonlinear models result in more accurate predictions of wall shear stress within a stented arterial segment.

[1]  P. Serruys,et al.  Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries. , 2003, The American journal of cardiology.

[2]  M Pohl,et al.  In vitro testing of artificial heart valves: comparison between Newtonian and non-Newtonian fluids. , 1996, Artificial organs.

[3]  Y A Kurochkin Automation of cardiological mass testing of population , 1974, Biomedical engineering.

[4]  Rosaire Mongrain,et al.  Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments , 2009, Biomedical engineering online.

[5]  M Ojha,et al.  Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model. , 1993, Journal of biomechanics.

[6]  R. Schroter,et al.  Atheroma and arterial wall shear - Observation, correlation and proposal of a shear dependent mass transfer mechanism for atherogenesis , 1971, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[7]  A. Yoganathan,et al.  Biofluid Mechanics: The Human Circulation , 2006 .

[8]  Damien Coisne,et al.  Computational Approach to Estimating the Effects of Blood Properties on Changes in Intra-stent Flow , 2006, Annals of Biomedical Engineering.

[9]  S Chien,et al.  Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. , 1966, Journal of applied physiology.

[10]  John F LaDisa,et al.  Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. , 2005, Journal of applied physiology.

[11]  S. Grešová,et al.  Hemorheology and circulation. , 2009, Clinical hemorheology and microcirculation.

[12]  U. Siebert,et al.  Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-Up: A Multicenter Registry , 2002, Circulation.

[13]  Erwan Donal,et al.  Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress. , 2003, Journal of biomechanics.

[14]  Nikos Stergiopulos,et al.  Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent Implantation: Inhibition Through Reduction of Inflammation? , 2003, Circulation.

[15]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[16]  J. LaDisa,et al.  Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation , 2003, Annals of Biomedical Engineering.

[17]  Michael R. Moreno,et al.  Stented Artery Flow Patterns and Their Effects on the Artery Wall , 2007 .

[18]  D D Duncan,et al.  Effects of arterial compliance and non-Newtonian rheology on correlations between intimal thickness and wall shear. , 1992, Journal of biomechanical engineering.

[19]  S Chien,et al.  Shear-dependent deformation of erythrocytes in rheology of human blood. , 1970, The American journal of physiology.