Establishment of a knee-joint coordinate system from helical axes analysis-a kinematic approach without anatomical referencing

This study establishes a functional knee-joint coordinate system (FCS) derived from active motion. The scale invariant properties of helical axes were used in order to avoid inter-observer errors associated with the traditional anatomical referencing techniques. The algorithm was tested with six cadaveric specimens in a knee-joint motion and loading apparatus. To determine the FCS sensitivity to variable loading, rotational moments were applied to the tibia while extending and flexing the knee. Each derived FCS was compared with the clinically derived anatomical coordinate system (ACS). The FCS was reproducible when the loading condition was the same. Changing the rotational moments from internal to external affected the orientations and the positions of the FCS. The largest displacement of 20.8 mm in average occurred in the medio/lateral direction. The FCS corresponded with the ACS for all specimens and loading conditions. The origin was always located within the femur along the transepicondylar line. The orientations differed less than 16.6/spl deg/ in average, thus allowing the use of clinical terminology. These findings suggest that the FCS might improve the ability to clinically assess kinematic alterations provided that the reference motion is reproducible.

[1]  C D Mote,et al.  A finite helical axis as a landmark for kinematic reference of the knee. , 1991, Journal of biomechanical engineering.

[2]  G. R. Pennock,et al.  An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. , 1990, Journal of biomechanics.

[3]  L Claes,et al.  The Influence of Muscle Forces and External Loads on Cruciate Ligament Strain , 1995, The American journal of sports medicine.

[4]  E Y Chao,et al.  A repeatable alignment method and local coordinate description for knee joint testing and kinematic measurement. , 1998, Journal of biomechanics.

[5]  H H Wetz,et al.  [Significance of 3 dimensional motion of the femurotibial joint for design of knee support orthoses]. , 2001, Der Orthopade.

[6]  L. Blankevoort,et al.  The envelope of passive knee joint motion. , 1988, Journal of biomechanics.

[7]  R. Huiskes,et al.  Instantaneous helical axis estimation via natural, cross-validated splines , 1987 .

[8]  J H Somerset,et al.  A three-dimensional study of the kinematics of the human knee. , 1975, Journal of biomechanics.

[9]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[10]  Jack Lewis,et al.  A Method for Locating an Optimal “Fixed” Axis of Rotation for the Human Knee Joint , 1978 .

[11]  L. Chèze,et al.  Comparison of different calculations of three-dimensional joint kinematics from video-based system data. , 2000, Journal of biomechanics.

[12]  C. Spoor,et al.  Rigid body motion calculated from spatial co-ordinates of markers. , 1980, Journal of biomechanics.

[13]  J. Kärrholm,et al.  Three‐dimensional knee joint movements during a step‐up: Evaluation after anterior cruciate ligament rupture , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  S. Stanhope,et al.  The effect of variation in knee center location estimates on net knee joint moments. , 1998, Gait & posture.

[15]  J Hoschek,et al.  [Mathematical kinematic methods in joint prosthetics]. , 1984, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[16]  Wetz Hh,et al.  Significance of 3 dimensional motion of the femurotibial joint for design of knee support orthoses , 2001 .

[17]  L Blankevoort,et al.  Helical axes of passive knee joint motions. , 1990, Journal of biomechanics.

[18]  P R Cavanagh,et al.  ISB recommendations for standardization in the reporting of kinematic data. , 1995, Journal of biomechanics.

[19]  L Claes,et al.  Correction of axis misalignment in the analysis of knee rotations. , 2003, Human movement science.

[20]  Y Hirasawa,et al.  Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. , 2001, The Journal of arthroplasty.

[21]  F. Veldpaus,et al.  Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. , 1985, Journal of biomechanics.

[22]  B. Fregly,et al.  Determination of joint functional axes from noisy marker data using the finite helical axis , 1998 .

[23]  B B Seedhom,et al.  Axis Location of Tibial Rotation and Its Change With Flexion Angle , 2000, Clinical orthopaedics and related research.

[24]  P R Cavanagh,et al.  Three-dimensional kinematics of the human knee during walking. , 1992, Journal of biomechanics.

[25]  E. Chao,et al.  Justification of triaxial goniometer for the measurement of joint rotation. , 1980, Journal of biomechanics.

[26]  J G Andrews On the specification of joint configurations and motions. , 1984, Journal of biomechanics.

[27]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[28]  H. H. Wetz,et al.  Use of spatial motion of the femorotibial joint for the alignment of knee braces , 2001 .

[29]  S. Zaffagnini,et al.  Determination of an Optimal Kinematic Protocol for Computer-Assisted Evaluation of Anterior Cruciate Ligament Deficiency , 2001, Annals of Biomedical Engineering.

[30]  Manfred Husty,et al.  Kinematik und Robotik , 1997 .

[31]  S. Piazza,et al.  Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. , 2000, Journal of biomechanics.

[32]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[33]  Frigo,et al.  Multifactorial estimation of hip and knee joint centres for clinical application of gait analysis. , 1998, Gait & posture.

[34]  R Shiavi,et al.  Helical motion analysis of the knee--I. Methodology for studying kinematics during locomotion. , 1987, Journal of biomechanics.

[35]  J. Silber,et al.  Determining femoral rotational alignment in total knee arthroplasty: reliability of techniques. , 2001, The Journal of arthroplasty.