Measurement of the harmonic distortion of the insulation loss current as a diagnostic tool for high voltage cable insulation

The 60 Hz insulation loss current measurements in high voltage cable insulation containing water trees are described. To isolate the small insulation loss current from the significantly larger, quadrature (capacitive) current, a current-comparator-based high voltage capacitance bridge was used. It is shown that water trees introduce higher harmonics into the insulation loss current waveform and that the harmonic distortion of the loss current can be correlated with the length of water trees. Current waveforms for insulation free of water trees or insulation in which the water trees were completely dried out showed negligible harmonic distortion. Insulation with partially dried water trees maintained significant harmonic distortion of the loss current even though the loss tangent was very much reduced. The diagnostic aspect of the described measurements is discussed.

[1]  M. Beigert,et al.  Destruction free ageing diagnosis of power cable insulation using the isothermal relaxation current analysis , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[2]  J. Densley,et al.  Ageing and diagnostics in extruded insulations for power cables , 1995, Proceedings of 1995 IEEE 5th International Conference on Conduction and Breakdown in Solid Dielectrics.

[3]  P. Werelius,et al.  Diagnosis of medium voltage XLPE cables by high voltage dielectric spectroscopy , 1998, ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132).

[4]  A. Bulinski,et al.  Water treeing in binary linear polyethylene blends: the mechanical aspect , 1994 .

[5]  M. Shaw,et al.  Water Treeing in Solid Dielectrics , 1984, IEEE Transactions on Electrical Insulation.

[6]  A. Bulinski,et al.  The Voltage Breakdown Characteristics of Miniature XLPE Cables Containing Water Trees , 1981, IEEE Transactions on Electrical Insulation.

[7]  E. So,et al.  Diagnostic measurements of high voltage polymeric cable insulation , 1995, Proceedings of 1995 International Symposium on Electrical Insulating Materials.

[8]  M. Mashikian,et al.  Evaluation of field aged crosslinked polyethylene cables by partial discharge location , 1994 .

[9]  M. Kosaki,et al.  New approach to diagnostic method of water trees , 1990, IEEE International Symposium on Electrical Insulation.

[10]  Robert J. Ross,et al.  Inception and propagation mechanisms of water treeing , 1998 .

[11]  E. So,et al.  Diagnostic measurements of high voltage insulation using current comparator technology , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[12]  P. N. Miljanic,et al.  The Current Comparator , 1988 .