X-ray characterisation of normal and neoplastic breast tissues.

Normal and neoplastic breast tissues have been characterised in terms of x-ray attenuation. Samples of normal fat and fibrous tissue were obtained from reduction mammoplasty and autopsy, and infiltrating duct carcinoma specimens from mastectomy and lumpectomy. A high-purity germanium spectroscopy system and a beam of 120 kV constant potential x-rays were used to determine the linear attenuation coefficient from 18 to 110 keV. Densities were determined from buoyancy measurements and were used to obtain mass attenuation coefficients. Infiltrating duct carcinomas and fat are well distinguished by x-ray attenuation. For photon energies used for film-screen mammography, infiltrating duct carcinomas are more attenuating than fibrous tissue. Above 31 keV, the ranges of attenuation of the two tissue types overlap. The attenuation coefficients of tissues have been concisely represented by equivalent thicknesses of lucite and aluminium. Analysis based on the average attenuation properties of tissues indicates that dual-energy mammography, using an ideal imaging system, would require 0.06 cGy to provide images in which 1 cm infiltrating duct carcinomas are displayed with a signal to noise ratio of 5 against a background over which the fat/fibrous contrast has been suppressed. This dose is similar to that currently used in conventional film-screen mammography.

[1]  F. Foster,et al.  Frequency dependence of ultrasound attenuation and backscatter in breast tissue. , 1986, Ultrasound in medicine & biology.

[2]  M J Yaffe,et al.  Theoretical optimization of dual-energy x-ray imaging with application to mammography. , 1985, Medical physics.

[3]  A Fenster,et al.  Dual-energy mammography: initial experimental results. , 1985, Medical physics.

[4]  H Bernstein,et al.  An approach to specifying a minimum dose system for mammography using multiparameter optimization techniques. , 1985, Medical physics.

[5]  T. Villafana,et al.  Dosage evaluation in mammography. , 1984, Radiology.

[6]  Fred H. Tenney,et al.  Idealized pulse pileup effects on energy spectra , 1984 .

[7]  S J Dwyer,et al.  Computed tomographic mammography using a conventional body scanner. , 1982, AJR. American journal of roentgenology.

[8]  R. J. Eastgate,et al.  Optimal x-ray spectra for screen-film mammography. , 1981, Medical physics.

[9]  A. Macovski,et al.  Generalized image combinations in dual KVP digital radiography. , 1981, Medical physics.

[10]  J. J. Gisvold,et al.  Computed tomographic mammography (CTM). , 1979, AJR. American journal of roentgenology.

[11]  S J Dwyer,et al.  Specific value of computed tomographic breast scanner (CT/M) in diagnosis of breast diseases. , 1979, Radiology.

[12]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[13]  M Danos,et al.  Image information content and patient exposure. , 1978, Medical physics.

[14]  Robin P. Gardner,et al.  A generalized method for correcting pulse-height spectra for the peak pile-up effect due to double sum pulses: Part I. Predicting spectral distortion for arbitrary pulse shapes , 1977 .

[15]  Robin P. Gardner,et al.  A generalized method for correcting pulse-height spectra for the peak pile-up effect due to double sum pulses. Part II. The inverse calculation for obtaining true from observed spectra , 1977 .

[16]  M Yaffe,et al.  Spectroscopy of diagnostic x rays by a Compton-scatter method. , 1976, Medical physics.

[17]  Robin P. Gardner,et al.  Prediction of the pulse-height spectral distortion caused by the peak pile-up effect , 1976 .

[18]  E. Hoffman,et al.  Attenuation coefficients of various body tissues, fluids, and lesions at photon energies of 18 to 136 keV. , 1975, Radiology.

[19]  E. C. Gregg,et al.  Attenuation of monoenergetic gamma rays in tissues. , 1975, The American journal of roentgenology, radium therapy, and nuclear medicine.