MIPAS-ENVISAT limb-sounding measurements: trade-off study for improvement of horizontal resolution.

The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) is a limb-scanning spectrometer that has operated onboard the Environmental Satellite since the end of March 2002. Common features of limb-scanning experiments are both high vertical resolution and poor horizontal resolution. We exploit the two-dimensional geo-fit retrieval approach [Appl. Opt. 40, 1872-1875 (2001)] to investigate the possibility of improving the horizontal resolution of MIPAS measurements. Two different strategies are considered for this purpose, one exploiting the possibility (offered by the geo-fit analysis method) for an arbitrary definition of the retrieval grid, the other based on the possibility of saving measurement time by degrading the spectral resolution of the interferometer. The performances of the two strategies are compared in terms of the trade-off between the attained horizontal resolution and the retrieval precision. We find that for ozone it is possible to improve by a factor of 2 the horizontal resolution, which in the nominal measurement plan is approximately 530 km. This improvement corresponds to a degradation of the retrieval precision, which on average varies from a factor of 1.4 to 2.5, depending on the adopted spectral resolution.

[1]  Franz Schreier,et al.  Modelling of atmospheric mid-infrared radiative transfer: the AMIL2DA algorithm intercomparison experiment , 2003 .

[2]  Simone Ceccherini,et al.  Level 2 near-real-time analysis of MIPAS measurements on ENVISAT , 2003, SPIE Remote Sensing.

[3]  Marco Ridolfi,et al.  MIPAS Level 2 Processor Performance and Verification , 2003 .

[4]  M. Carlotti Global-fit approach to the analysis of limb-scanning atmospheric measurements. , 1988, Applied optics.

[5]  R. Norton,et al.  New apodizing functions for Fourier spectrometry , 1976 .

[6]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[7]  M. Endemann MIPAS Instrument Concept and Performance , 2000 .

[8]  Bruno Carli,et al.  Approach to the design and data analysis of a limb-scanning experiment. , 1994, Applied optics.

[9]  M Carlotti,et al.  Geo-fit Approach to the Analysis of Limb-Scanning Satellite Measurements. , 2001, Applied optics.

[10]  Martyn P. Chipperfield,et al.  Multiannual simulations with a three‐dimensional chemical transport model , 1999 .

[11]  F. X. Kneizys,et al.  Line shape and the water vapor continuum , 1989 .

[12]  Vertical resolution of oversampled limb-sounding measurements from satellites and aircraft , 2002 .

[13]  T. von Clarmann,et al.  Selection of optimized microwindows for atmospheric spectroscopy. , 1998, Applied optics.

[14]  P. E. Morris,et al.  Optimized forward model and retrieval scheme for MIPAS near-real-time data processing. , 2000, Applied optics.

[15]  Clive D Rodgers,et al.  Inverse Methods for Atmospheric Sounding: Theory and Practice , 2000 .

[16]  M Carlotti,et al.  Derivation of temperature and pressure from submillimetric limb observations. , 1999, Applied optics.

[17]  Barney J. Conrath,et al.  Vertical Resolution of Temperature Profiles Obtained from Remote Radiation Measurements. , 1972 .

[18]  M. Ridolfi,et al.  Multi-target retrieval (MTR): the simultaneous retrieval of pressure, temperature and volume mixing ratio profiles from limb-scanning atmospheric measurements , 2004 .

[19]  G. Backus,et al.  Uniqueness in the inversion of inaccurate gross Earth data , 1970, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences.