Accurate Measurement of Extrudate Temperature and Heat Loss On A Twin‐Screw Extruder
暂无分享,去创建一个
Infrared (IR), extended melt and flush thermocouple probes were used to measure bulk temperatures of extrudates. Good agreement was obtained between IR and extended probes. However, substantial differences were observed between IR and flush mounted probes and between extended and flush mounted probes. A response surface methodology was used to study effects of moisture screw speed, and barrel temperature on measured temperature differences between IR and flush probes. The standard flush probe may not accurately measure bulk temperature of the extrudate. The heat flux from the surfaces (top, bottom, and side) of a twin-screw extruder barrel was also measured. Total heat loss from the surface varied between 2-19% of the total heat input.