Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions.

UNLABELLED CT-based attenuation correction is a widely used option in commercial PET/CT scanners. However, as a result of a nonsimultaneous acquisition and differences in temporal resolution between both modalities, a potential misregistration between the PET and CT, especially in the thorax and the upper abdomen, can be found. We observed a substantial number of apparent perfusion defects in spatial coincidence with the misregistered segments of the heart and assumed these defects were related to an incorrect attenuation correction. The purpose of this work was to assess the clinical impact of emission-transmission misalignment in myocardial perfusion imaging with PET/CT and to investigate potential solutions. METHODS Twenty-eight coronary artery disease patients underwent PET/CT (13)NH3 rest/stress examinations. The emission-transmission misalignment was corrected by manual registration and the PET studies were reconstructed again using the realigned CT images for attenuation correction. The effects of the registration were evaluated by quantitative analysis of the local tracer uptake on a polar map basis. In addition to manual registration, 2 alternative realignment methods were evaluated: mutual information-based image registration and emission-driven correction based on the outline of the heart in the PET image. RESULTS Manual realignment resulted in a change in the defect size of >10% of the left ventricle in 6 of 28 studies (21.4%); in 5 of the studies, this resulted in the disappearance of large apparent perfusion defects (15%-46% of the left ventricle), which were fully due to emission-transmission misregistration. Automatic image registration was unable to realign the datasets, whereas the emission-driven correction showed a good agreement with manual registration. CONCLUSION Misregistration of PET and CT images is common in cardiac PET/CT studies and results in artifacts on the attenuation-corrected PET images, which appear to be corrected by repeating the PET reconstruction after manual realignment of the CT image data. In contrast to manual realignment, an automated emission-driven correction appears to be a promising approach.

[1]  Thomas Beyer,et al.  Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[2]  M Schwaiger,et al.  Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Catalin Loghin,et al.  Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  R. Castillo,et al.  Attenuation correction of PET images with respiration-averaged CT images in PET/CT. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[6]  Paul Kinahan,et al.  Attenuation correction for a combined 3D PET/CT scanner. , 1998, Medical physics.

[7]  R. Shekhar,et al.  Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[9]  Oliver Lindner,et al.  A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT Introduced by misalignment between emission scan and CT-derived attenuation maps. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Stephan G. Nekolla,et al.  Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography , 1998, European Journal of Nuclear Medicine.

[11]  David Atkinson,et al.  A study of the motion and deformation of the heart due to respiration , 2002, IEEE Transactions on Medical Imaging.

[12]  Cyrill Burger,et al.  PET-CT image co-registration in the thorax: influence of respiration , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[13]  R. Körfer,et al.  18F-FDG PET for detecting myocardial viability: validation of 3D data acquisition. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Yuji Nakamoto,et al.  Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[16]  V. Dilsizian,et al.  Misalignment between PET transmission and emission scans: its effect on myocardial imaging. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  Cyrill Burger,et al.  CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Mark Lubberink,et al.  Quantitative comparison of analytic and iterative reconstruction methods in 2- and 3-dimensional dynamic cardiac 18F-FDG PET. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.