A Patient-Specific Study Investigating the Relation between Coronary Hemodynamics and Neo-Intimal Thickening after Bifurcation Stenting with a Polymeric Bioresorbable Scaffold

We present an application of a validated reconstruction methodology for the comparison between patient-specific hemodynamics and neo-intimal thickening at nine months from the intervention. (1) Background: Coronary bifurcation stenting alters the vessel geometry, influencing the local hemodynamics. The evaluation of wall shear stress (WSS) relies on the application of computational fluid dynamics to model its distribution along the coronary tree. The endothelium actively responds to WSS, which triggers eventual cell proliferation to cover the stent struts. (2) Methods: Baseline optical coherence tomography and angiographic data were combined to reconstruct a patient-specific coronary bifurcation with an implanted bioresorbable scaffold and to simulate the hemodynamics. Results were linked with the neo-intimal thickening after nine months from the intervention. (3) Results: Blood velocity patterns were disrupted at the bifurcation due to the presence of the stent. It was observed that 55.6% of the scaffolded lumen surface was exposed to values of time-averaged WSS lower than 0.4 Pa. Follow-up images showed a luminal narrowing of 19% in the main branch. There was also a complete coverage in 99% of struts. (4) Conclusions: This approach provided valuable complementary information that might improve the clinical outcomes in this subset of coronary diseases.

[1]  Alfonso Medina,et al.  Una clasificación simple de las lesiones coronarias en bifurcación , 2006 .

[2]  Michail I. Papafaklis,et al.  Relation of distribution of coronary blood flow volume to coronary artery dominance. , 2013, American Journal of Cardiology.

[3]  Andrew Ooi,et al.  Endothelial shear stress 5 years after implantation of a coronary bioresorbable scaffold , 2018, European heart journal.

[4]  Patrick W Serruys,et al.  Association of wall shear stress with long-term vascular healing response following bioresorbable vascular scaffold implantation. , 2015, International journal of cardiology.

[5]  M. Caputo,et al.  Simulation of oxygen transfer in stented arteries and correlation with in‐stent restenosis , 2013, International journal for numerical methods in biomedical engineering.

[6]  Erhan Tenekecioglu,et al.  Bioresorbable Scaffold: The Emerging Reality and Future Directions , 2017, Circulation research.

[7]  Luca Mainardi,et al.  Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method , 2017, PloS one.

[8]  F. N. van de Vosse,et al.  The influence of boundary conditions on wall shear stress distribution in patients specific coronary trees. , 2011, Journal of biomechanics.

[9]  Kim Van der Heiden,et al.  The effects of stenting on shear stress: relevance to endothelial injury and repair. , 2013, Cardiovascular research.

[10]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[11]  Bernard Chevalier,et al.  Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial , 2016, The Lancet.

[12]  Michail I. Papafaklis,et al.  Effect of the endothelial shear stress patterns on neointimal proliferation following drug-eluting bioresorbable vascular scaffold implantation: an optical coherence tomography study. , 2014, JACC: Cardiovascular Interventions.

[13]  P. Serruys,et al.  Snowshoe Versus Ice Skate for Scaffolding of Disrupted Vessel Wall. , 2015, JACC. Cardiovascular interventions.

[14]  Claudio Chiastra,et al.  Patient-Specific Modeling of Stented Coronary Arteries Reconstructed from Optical Coherence Tomography: Towards a Widespread Clinical Use of Fluid Dynamics Analyses , 2017, Journal of Cardiovascular Translational Research.

[15]  Jeroen Eggermont,et al.  Automatic detection of bioresorbable vascular scaffold struts in intravascular optical coherence tomography pullback runs. , 2014, Biomedical optics express.

[16]  Claudio Chiastra,et al.  Computational fluid dynamics of stented coronary bifurcations studied with a hybrid discretization method , 2012 .

[17]  F. Migliavacca,et al.  Modeling of Blood Flow in Stented Coronary Arteries , 2015 .

[18]  Alun D. Hughes,et al.  Evidence of a Dominant Backward-Propagating “Suction” Wave Responsible for Diastolic Coronary Filling in Humans, Attenuated in Left Ventricular Hypertrophy , 2006, Circulation.

[19]  J. Suárez de Lezo,et al.  [A new classification of coronary bifurcation lesions]. , 2006, Revista espanola de cardiologia.

[20]  Claudio Chiastra,et al.  On the necessity of modelling fluid-structure interaction for stented coronary arteries. , 2014, Journal of the mechanical behavior of biomedical materials.

[21]  Evelyn Regar,et al.  Optical coherence tomography for evaluation of coronary stents in vivo , 2013, Expert review of cardiovascular therapy.

[22]  Luca Mainardi,et al.  A framework for computational fluid dynamic analyses of patient-specific stented coronary arteries from optical coherence tomography images. , 2017, Medical engineering & physics.