MR compatible actuation for medical instrumentation

Surgical robots and especially their subclass of image-guided systems require special design, construction and control compared to industrial types, due to the special requirements of the medical and imaging environments. Imager compatibility raises significant engineering challenges for the development of robotic manipulators with respect to imager access, safety, ergonomics, and above all the non-interference with the functionality of the imager. These apply to all known medical imaging types, but are especially challenging for achieving compatibility with the class of magnetic resonance imaging (MRI) systems. Even though a large majority of robotic components may be redesigned to be constructed of MRI compatible materials, for other components such as the motors used in actuation, prescribing MRI compatible materials alone is not sufficient. The electromagnetic motors most commonly used in robotic actuation, for example, are incompatible by principle. We report here an important achievement in MRI instrumentation, a new type of pneumatic motor, PneuStep (Stoianovici et al., 2007), specifically developed for MrBot, the first pneumatic, fully actuated MR robotic system that can be located within the scanner alongside the patient and operating under remote control based on the images.

[1]  W. Kaiser,et al.  ROBITOM- ROBOT FOR BIOPSY AND THERAPY OF THE MAMMA , 2002 .

[2]  Gary M. Bone,et al.  Accurate position control of a pneumatic actuator using on/off solenoid valves , 1997, Proceedings of International Conference on Robotics and Automation.

[3]  W. Kaiser,et al.  Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit. , 2000, Investigative radiology.

[4]  Septimiu E. Salcudean,et al.  A force-controlled pneumatic actuator , 1995, IEEE Trans. Robotics Autom..

[5]  A. Patriciu,et al.  A New Type of Motor: Pneumatic Step Motor , 2007, IEEE/ASME Transactions on Mechatronics.

[6]  Yildirim Hurmuzlu,et al.  A High Performance Pneumatic Force Actuator System: Part I—Nonlinear Mathematical Model , 2000 .

[7]  Gary M. Bone,et al.  Accurate position control of a pneumatic actuator using on/off solenoid valves , 1997 .

[8]  Chang-Soo Han,et al.  Development of hybrid robot for construction works with pneumatic actuator , 2005 .

[9]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[10]  H Iseki,et al.  Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. , 1995, Journal of image guided surgery.

[11]  T. Hägglund A friction compensator for pneumatic control valves , 2002 .

[12]  Stephanus Büttgenbach,et al.  Novel micro-pneumatic actuator for MEMS , 2002 .

[13]  H. Kaminaga,et al.  Robust Nonlinear Control of Parametric Uncertain Systems With Unknown Friction and Its Application to a Pneumatic Control Valve , 2000 .

[14]  Jyh-Chyang Renn,et al.  A study on the speed control performance of a servo-pneumatic motor and the application to pneumatic tools , 2004 .

[15]  D Stoianovici,et al.  Multi‐imager compatible actuation principles in surgical robotics , 2005, The international journal of medical robotics + computer assisted surgery : MRCAS.

[16]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[17]  K Chinzei,et al.  Towards MRI guided surgical manipulator. , 2001, Medical science monitor : international medical journal of experimental and clinical research.

[18]  Ron Kikinis,et al.  MR Compatibility of Mechatronic Devices: Design Criteria , 1999, MICCAI.

[19]  D. Louw,et al.  Surgical Robotics: A Review and Neurosurgical Prototype Development , 2004, Neurosurgery.

[20]  D. Stoianovici,et al.  Magnetic resonance imaging compatible robotic system for fully automated brachytherapy seed placement. , 2006, Urology.

[21]  J. Neuerburg,et al.  Neues MR-(und CT-)kompatibles Knochenbiopsiesystem: Erste klinische Ergebnisse , 1998 .

[22]  Yildirim Hurmuzlu,et al.  A High Performance Pneumatic Force Actuator System: Part II—Nonlinear Controller Design , 2000 .

[23]  M. Bock,et al.  An MRI-Compatible Surgical Robot for Precise Radiological Interventions , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.