Detection of corona with RF methods and spectra analysis

High voltage power electronic systems are increasingly being used in applications such as renewable energy generation and in transportation systems. Such high voltage systems are often placed in compact packages to minimize weight and volume. In minimizing package size, there are consequences on the design of the high voltage insulation system which is likely to be operated closer to design limits. This can lead to an increasing number of failures due to tracking, partial discharges or disruptive discharge. An opportunity therefore exists to develop a monitoring system that can detect a range of electrical discharges and which is able to work in environments polluted by electromagnetic noise generated by rapid switching of power electronics under any load conditions. Of the methods that have been developed in recent years (optical, ultrasonic, RF etc.) the ones based on RF techniques are the most promising. To enable an easy differentiation between the RF signals produced by a PD and the random environmental noise it is crucial to understand the type of emissions that can be generated by different kind of discharges. In this experimental work carried out in a controlled electromagnetic noise-free environment, arbitrary corona discharges (of known magnitude and polarity) have been detected with RF techniques and the signals have been analyzed. Results relative to positive and negative corona generated with blade-plane gap specimen at varying voltages (1-4kV) and at differing pressures (11-101.3 kPa) are reported. This is the first part of a study targeted to classify the spectral emissions associated with different PDs; future work will analyze emissions due to voids, floating particles, tracking etc. The final aim of this project is the development of a system capable of a monitoring a range of discharge types in high voltage power converters including those operated at altitude in aerospace applications.

[2]  Li Chengrong,et al.  Multi-PD sources location by UWB RF detection on power transformers and a case study on-site , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[3]  S. Okabe,et al.  Cross-equipment Evaluation of Partial Discharge Measurement and Diagnosis Techniques in Electric Power Apparatus for Transmission and Distribution , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  E. Husain,et al.  Surface Discharge Studies with Uniform Field Electrodes at Low Pressures , 1981, IEEE Transactions on Electrical Insulation.

[5]  Mohammad Khalifa High-voltage engineering : theory and practice , 1990 .

[6]  P.J. Moore,et al.  Radiometric location of partial discharge sources on energized high-Voltage plant , 2005, IEEE Transactions on Power Delivery.

[7]  S. Sebo,et al.  Low-Pressure Partial-Discharge Measurements: Monitoring the Insulation Integrity of Aircraft Power Wiring Systems , 2008, 2008 IEEE International Power Modulators and High-Voltage Conference.

[8]  Philip J. Moore,et al.  Pollution of the radio spectrum from the generation of impulsive noise by high voltage equipment , 2002 .

[9]  G. Stone Importance of bandwidth in PD measurement in operating motors and generators , 2000 .

[10]  S. Tenbohlen,et al.  Detection and location of partial discharges in power transformers using acoustic and electromagnetic signals , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  M D Judd,et al.  Simultaneous measurement of partial discharges using IEC60270 and radio-frequency techniques , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  S. Sebo,et al.  Partial discharge characteristics at low pressures in dry air and argon , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.

[13]  H. Muto,et al.  Detecting characteristics of various type antennas on partial discharge electromagnetic wave radiating through insulating spacer in gas insulated switchgear , 2009, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  B. Stewart,et al.  Comparing IEC60270 and RF partial discharge patterns , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[16]  S. Sebo,et al.  Partial discharge measurements in air and argon at low pressures with and without a dielectric barrier , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[17]  K. Raja,et al.  Recognition of discharge sources using UHF PD signatures , 2002 .

[18]  F. H. Kreuger,et al.  Partial Discharge Detection in High Voltage Equipment , 1990 .

[19]  R. Sloan,et al.  Comparison of IEC 60270 and RF partial discharge detection in an electromagnetic noise-free environment at differing pressures , 2012, 2012 IEEE International Symposium on Electrical Insulation.

[20]  M.D. Judd Radiometric partial discharge detection , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[21]  M.D. Judd,et al.  Frequency distribution of RF energy from PD sources and its application in combined RF and IEC60270 measurements , 2006, 2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[22]  S. Tenbohlen,et al.  Sensitivity of UHF PD measurements in power transformers , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  Li Yang,et al.  Investigation of radiometric partial discharge detection for use in switched HVDC testing , 2006, 2006 IEEE Power Engineering Society General Meeting.