Development of a portable sensor to evaluate copper speciation in natural waters

This work presents a new portable sensor to evaluate total dissolved copper and labile copper in natural waters, which is particularly valuable for the assessment of the toxicity of this metal towards aquatic biota. The sensor was constructed using graphite rod electrodes electropolymerized with 5-(4-allyloxy-phenylazo)-quinolin-8-ol (APQO). The metal preconcentration step was an electroless process performed by simply dipping the modified electrode (ME) into the sample. The polymerized electrode could be stored inside a common plastic bag at room temperature for at least 10 days, and once the Cu–APQO complex was formed, the ME was stable for up to 7 days at room temperature. These properties can greatly facilitate fieldwork. The best voltammetric response for complexed copper reduction was obtained in 0.1 mol L−1 phosphate buffer, at pH 7.3, using differential pulse (25 mV) and a scan rate of 20 mV s−1. The linear response for copper spanned nine orders of magnitude, from 10−9 to 10−1 mol L−1, with a detection limit of 0.3 × 10−9 mol L−1 and a relative standard deviation of 8.3% for copper at 1.03 × 10−6 mol L−1. Common trace metals in natural waters such as Pb, Cd, Fe, Mn, Ni, Cr, and Zn at concentrations 1000 times higher than that of copper did not interfere with the copper signal. The accuracy of the method was confirmed by the analysis of a certified river water sample and by comparison with the results obtained using adsorptive cathodic stripping voltammetry with oxine. The proposed sensor is inexpensive, stable, selective, and enables evaluation of the most bioavailable fraction of copper in natural waters.

[1]  Dawei Pan,et al.  In-situ synthesis of reduced graphene oxide/gold nanoparticles modified electrode for speciation analysis of copper in seawater. , 2017, Talanta.

[2]  A. Afkhami,et al.  Construction of Modified Carbon Paste Electrode for Highly Sensitive Simultaneous Electrochemical Determination of Trace Amounts of Copper (II) and Cadmium (II) , 2016 .

[3]  H. Whitby,et al.  Evidence for copper-binding humic substances in seawater , 2015 .

[4]  A. Walcarius Electrocatalysis, sensors and biosensors in analytical chemistry based on ordered mesoporous and macroporous carbon-modified electrodes , 2012 .

[5]  A. Ramanavičius,et al.  Square wave voltammetry based on determination of copper (II) ions by polyluteolin- and polykaempferol-modified electrodes. , 2011, Talanta.

[6]  Qian Cao,et al.  Poly(2-amino-4-thiazoleacetic acid)/multiwalled carbon nanotubes modified glassy carbon electrodes for the electrochemical detection of copper(II) , 2010 .

[7]  Rodney K. Lyn,et al.  Cellular lipid metabolism is influenced by the coordination environment of copper. , 2009, Journal of the American Chemical Society.

[8]  K. Bruland,et al.  A review of total dissolved copper and its chemical speciation in San Francisco Bay, California. , 2007, Environmental research.

[9]  B. Jones,et al.  Copper speciation survey from UK marinas, harbours and estuaries. , 2007, Marine pollution bulletin.

[10]  Jiujun Zhang,et al.  Graphite electrodes modified by 8-hydroxyquinolines and its application for the determination of copper in trace levels , 2006 .

[11]  M. Campos,et al.  Preparation and characterization of electrochemically modified electrodes containing the metal complexing moiety quinolin-8-ol anchored to the polymeric film , 2005 .

[12]  M. Campos,et al.  Construção e otimização de um reator de baixo custo para a fotodegradação da matéria orgânica em águas naturais e sua aplicação no estudo da especiação do cobre por voltametria , 2001 .

[13]  Si‐Xuan Guo,et al.  Rapidly renewable and reproducible electropolymerized surface at a monomer modified carbon paste electrode , 1999 .

[14]  J. Labuda,et al.  Theory and application of chemically modified carbon paste electrode to copper speciation determination , 1995 .

[15]  C. V. D. Berg,et al.  Determination of copper complexation in sea water by cathodic stripping voltammetry and ligand competition with salicylaldoxime , 1994 .

[16]  Constant M.G. van den Berg,et al.  Potentials and potentialities of cathodic stripping voltammetry of trace elements in natural waters , 1991 .

[17]  C. V. D. Berg Determination of copper, cadmium and lead in seawater by cathodic stripping voltammetry of complexes with 8-hydroxyquinoline , 1986 .

[18]  G. Batley,et al.  Chemical Speciation in Natural Waters , 1980 .

[19]  Arthur T. Hubbard,et al.  Electrochemistry of chemisorbed molecules. I. Reactants connected to electrodes through olefinic substituents , 1973 .

[20]  E. Neves,et al.  Titulações potenciométricas de cátions metálicos tendo como eletrodo indicador o sistema Cu/Cu(II)-EDTA , 2008 .

[21]  D. Arrigan Tutorial review. Voltammetric determination of trace metals and organics after accumulation at modified electrodes , 1994 .

[22]  T. Florence,et al.  Electrochemical approaches to trace element speciation in waters , 1986 .