Slab reinforcement location versus code specification

A review is made of the interacting Australian codes controlling the construction of reinforced concrete slabs, individual tolerances are assessed and a simplified analysis performed to indicate the magnitude of the variability problem for both top and bottom bars. It has been concluded that standard practice cannot achieve the depth and cover requirements of the related Australian codes. Specific code amendments have been proposed to achieve a better match between specification, codes and practice (a).