Increased robustness of single-molecule counting with microfluidics, digital isothermal amplification, and a mobile phone versus real-time kinetic measurements.

Quantitative bioanalytical measurements are commonly performed in a kinetic format and are known to not be robust to perturbation that affects the kinetics itself or the measurement of kinetics. We hypothesized that the same measurements performed in a "digital" (single-molecule) format would show increased robustness to such perturbations. Here, we investigated the robustness of an amplification reaction (reverse-transcription loop-mediated amplification, RT-LAMP) in the context of fluctuations in temperature and time when this reaction is used for quantitative measurements of HIV-1 RNA molecules under limited-resource settings (LRS). The digital format that counts molecules using dRT-LAMP chemistry detected a 2-fold change in concentration of HIV-1 RNA despite a 6 °C temperature variation (p-value = 6.7 × 10(-7)), whereas the traditional kinetic (real-time) format did not (p-value = 0.25). Digital analysis was also robust to a 20 min change in reaction time, to poor imaging conditions obtained with a consumer cell-phone camera, and to automated cloud-based processing of these images (R(2) = 0.9997 vs true counts over a 100-fold dynamic range). Fluorescent output of multiplexed PCR amplification could also be imaged with the cell phone camera using flash as the excitation source. Many nonlinear amplification schemes based on organic, inorganic, and biochemical reactions have been developed, but their robustness is not well understood. This work implies that these chemistries may be significantly more robust in the digital, rather than kinetic, format. It also calls for theoretical studies to predict robustness of these chemistries and, more generally, to design robust reaction architectures. The SlipChip that we used here and other digital microfluidic technologies already exist to enable testing of these predictions. Such work may lead to identification or creation of robust amplification chemistries that enable rapid and precise quantitative molecular measurements under LRS. Furthermore, it may provide more general principles describing robustness of chemical and biological networks in digital formats.

[1]  S H Neoh,et al.  Quantitation of targets for PCR by use of limiting dilution. , 1992, BioTechniques.

[2]  K. Livak,et al.  Real time quantitative PCR. , 1996, Genome research.

[3]  Vincent C. Emery,et al.  J. Virol. Methods , 1996 .

[4]  Irving R. Epstein,et al.  An Introduction to Nonlinear Chemical Dynamics: Oscillations, Waves, Patterns, and Chaos , 1998 .

[5]  U. Alon,et al.  Robustness in bacterial chemotaxis , 2022 .

[6]  P. Belgrader,et al.  PCR Detection of Bacteria in Seven Minutes , 1999, Science.

[7]  C. Mirkin,et al.  Scanometric DNA array detection with nanoparticle probes. , 2000, Science.

[8]  T. Notomi,et al.  Accelerated reaction by loop-mediated isothermal amplification using loop primers. , 2002, Molecular and cellular probes.

[9]  Rustem F Ismagilov,et al.  A synthetic reaction network: chemical amplification using nonequilibrium autocatalytic reactions coupled in time. , 2004, Journal of the American Chemical Society.

[10]  Rustem F. Ismagilov,et al.  Dynamics of Drosophila embryonic patterning network perturbed in space and time using microfluidics , 2005, Nature.

[11]  Kristen L. Helton,et al.  Microfluidic Overview of Global Health Issues Microfluidic Diagnostic Technologies for Global Public Health , 2006 .

[12]  David R Walt,et al.  Digital readout of target binding with attomole detection limits via enzyme amplification in femtoliter arrays. , 2006, Journal of the American Chemical Society.

[13]  Stephen R. Quake,et al.  Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria , 2006, Science.

[14]  P. Neužil,et al.  Ultra fast miniaturized real-time PCR: 40 cycles in less than six minutes , 2006, Nucleic acids research.

[15]  A. Kutateladze,et al.  Photoinduced signal amplification through controlled externally sensitized fragmentation in masked sensitizers. , 2006, Journal of the American Chemical Society.

[16]  H. Kitano Towards a theory of biological robustness , 2007, Molecular systems biology.

[17]  N. Ford,et al.  HIV viral load monitoring in resource-limited regions: optional or necessary? , 2007, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[18]  D. Rudolph,et al.  Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP). , 2008, Journal of virological methods.

[19]  Jean Emberlin,et al.  PCR to predict risk of airborne disease. , 2008, Trends in microbiology.

[20]  G. Whitesides,et al.  Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis. , 2008, Analytical chemistry.

[21]  Yasuyoshi Mori,et al.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products , 2008, Nature Protocols.

[22]  R. Rosenfeld Nature , 2009, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[23]  David N Breslauer,et al.  Mobile Phone Based Clinical Microscopy for Global Health Applications , 2009, PloS one.

[24]  V. Beneš,et al.  The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. , 2009, Clinical chemistry.

[25]  Rustem F Ismagilov,et al.  Digital PCR on a SlipChip. , 2010, Lab on a chip.

[26]  Jesus Rodriguez-Manzano,et al.  Molecular detection of pathogens in water--the pros and cons of molecular techniques. , 2010, Water research.

[27]  Rustem F Ismagilov,et al.  Nanoliter multiplex PCR arrays on a SlipChip. , 2010, Analytical chemistry.

[28]  K. Plaxco,et al.  Sensitive and selective amplified fluorescence DNA detection based on exonuclease III-aided target recycling. , 2010, Journal of the American Chemical Society.

[29]  Joseph S. Takahashi,et al.  Temperature as a Universal Resetting Cue for Mammalian Circadian Oscillators , 2010, Science.

[30]  Florence Postollec,et al.  Recent advances in quantitative PCR (qPCR) applications in food microbiology. , 2011, Food microbiology.

[31]  Todd Munson,et al.  Theoretical design and analysis of multivolume digital assays with wide dynamic range validated experimentally with microfluidic digital PCR. , 2011, Analytical chemistry.

[32]  H. Bau,et al.  A self-heating cartridge for molecular diagnostics. , 2011, Lab on a chip.

[33]  Lulu Qian,et al.  Supporting Online Material Materials and Methods Figs. S1 to S6 Tables S1 to S4 References and Notes Scaling up Digital Circuit Computation with Dna Strand Displacement Cascades , 2022 .

[34]  Jacques Schrenzel,et al.  Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. , 2011, FEMS immunology and medical microbiology.

[35]  S. T. Phillips,et al.  A two-component small molecule system for activity-based detection and signal amplification: application to the visual detection of threshold levels of Pd(II). , 2011, Journal of the American Chemical Society.

[36]  Rustem F Ismagilov,et al.  Digital isothermal quantification of nucleic acids via simultaneous chemical initiation of recombinase polymerase amplification reactions on SlipChip. , 2011, Analytical chemistry.

[37]  I. Epstein,et al.  Tomography of Reaction-Diffusion Microemulsions Reveals Three-Dimensional Turing Patterns , 2011, Science.

[38]  S. T. Phillips,et al.  Design of small molecule reagents that enable signal amplification via an autocatalytic, base-mediated cascade elimination reaction. , 2012, Chemical communications.

[39]  Wei Jin,et al.  Self-priming compartmentalization digital LAMP for point-of-care. , 2012, Lab on a chip.

[40]  Gerald F. Joyce,et al.  Ligand-dependent exponential amplification of a self-replicating L-RNA enzyme. , 2012, Journal of the American Chemical Society.

[41]  Luke P. Lee,et al.  Digital LAMP in a sample self-digitization (SD) chip. , 2012, Lab on a chip.

[42]  Paul LaBarre,et al.  Isothermal Amplification Using a Chemical Heating Device for Point-of-Care Detection of HIV-1 , 2012, PloS one.

[43]  Bing Sun,et al.  Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol. , 2013, Analytical chemistry.

[44]  Y. Weizmann,et al.  Real-time detection of telomerase activity using the exponential isothermal amplification of telomere repeat assay. , 2013, Journal of the American Chemical Society.

[45]  Hongying Zhu,et al.  Optical imaging techniques for point-of-care diagnostics. , 2013, Lab on a chip.

[46]  Bingling Li,et al.  Real-time detection of isothermal amplification reactions with thermostable catalytic hairpin assembly. , 2013, Journal of the American Chemical Society.