The performance of a reduced-order adaptive controller when used in multi-antenna hyperthermia treatments with nonlinear temperature-dependent perfusion

In large multi-antenna systems, adaptive controllers can aid in steering the heat focus toward the tumor. However, the large number of sources can greatly increase the steering time. Additionally, controller performance can be degraded due to changes in tissue perfusion which vary non-linearly with temperature, as well as with time and spatial position. The current work investigates whether a reduced-order controller with the assumption of piecewise constant perfusion is robust to temperature-dependent perfusion and achieves steering in a shorter time than required by a full-order controller. The reduced-order controller assumes that the optimal heating setting lies in a subspace spanned by the best heating vectors (virtual sources) of an initial, approximate, patient model. An initial, approximate, reduced-order model is iteratively updated by the controller, using feedback thermal images, until convergence of the heat focus to the tumor. Numerical tests were conducted in a patient model with a right lower leg sarcoma, heated in a 10-antenna cylindrical mini-annual phased array applicator operating at 150 MHz. A half-Gaussian model was used to simulate temperature-dependent perfusion. Simulated magnetic resonance temperature images were used as feedback at each iteration step. Robustness was validated for the controller, starting from four approximate initial models: (1) a 'standard' constant perfusion lower leg model ('standard' implies a model that exactly models the patient with the exception that perfusion is considered constant, i.e., not temperature dependent), (2) a model with electrical and thermal tissue properties varied from 50% higher to 50% lower than the standard model, (3) a simplified constant perfusion pure-muscle lower leg model with +/-50% deviated properties and (4) a standard model with the tumor position in the leg shifted by 1.5 cm. Convergence to the desired focus of heating in the tumor was achieved for all four simulated models. The controller accomplished satisfactory therapeutic outcomes: approximately 80% of the tumor was heated to temperatures 43 degrees C and approximately 93% was maintained at temperatures <41 degrees C. Compared to the controller without model reduction, a approximately 9-25 fold reduction in convergence time was accomplished using approximately 2-3 orthonormal virtual sources. In the situations tested, the controller was robust to the presence of temperature-dependent perfusion. The results of this work can help to lay the foundation for real-time thermal control of multi-antenna hyperthermia systems in clinical situations where perfusion can change rapidly with temperature.

[1]  M. Kowalski,et al.  A temperature-based feedback control system for electromagnetic phased-array hyperthermia: theory and simulation. , 2003, Physics in medicine and biology.

[2]  Kung-Shan Cheng,et al.  Fast temperature optimization of multi-source hyperthermia applicators with reduced-order modeling of ‘virtual sources’ , 2008, Physics in medicine and biology.

[3]  J. Lagendijk,et al.  Towards patient specific thermal modelling of the prostate , 2006, Physics in Medicine and Biology.

[4]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[5]  Peter Wust,et al.  Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system. , 2007, Medical physics.

[6]  W. Joines,et al.  Theoretical and measured electric field distributions within an annular phased array: Consideration of source antennas , 1993, IEEE Transactions on Biomedical Engineering.

[7]  Amir Boag,et al.  Optimal excitation of multiapplicator systems for deep regional hyperthermia , 1988, 1988., IEEE MTT-S International Microwave Symposium Digest.

[8]  S K Das,et al.  A method of MRI-based thermal modelling for a RF phased array. , 2001, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[9]  K. M. Sekins,et al.  Local muscle blood flow and temperature responses to 915MHz diathermy as simultaneously measured and numerically predicted. , 1984, Archives of physical medicine and rehabilitation.

[10]  S L George,et al.  Sensitivity of hyperthermia trial outcomes to temperature and time: implications for thermal goals of treatment. , 1993, International journal of radiation oncology, biology, physics.

[11]  P Wust,et al.  A fast algorithm to find optimal controls of multiantenna applicators in regional hyperthermia. , 2001, Physics in medicine and biology.

[12]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[13]  S K Das,et al.  Electromagnetic thermal therapy power optimization for multiple source applicators. , 1999, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[14]  G. Raaphorst,et al.  Changes in muscle blood flow distribution during hyperthermia. , 1997, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[15]  C. Song Effect of local hyperthermia on blood flow and microenvironment: a review. , 1984, Cancer research.

[16]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[17]  Kung-Shan Cheng,et al.  Online feedback focusing algorithm for hyperthermia cancer treatment , 2007, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[18]  J. Rhee,et al.  Implication of Blood Flow in Hyperthermic Treatment of Tumors , 1984, IEEE Transactions on Biomedical Engineering.

[19]  R Vanderby,et al.  Temperature-dependent versus constant-rate blood perfusion modelling in ferromagnetic thermoseed hyperthermia: results with a model of the human prostate. , 1994, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[20]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[21]  M. Seebass,et al.  Impact of nonlinear heat transfer on temperature control in regional hyperthermia , 1999, IEEE Transactions on Biomedical Engineering.

[22]  C. Balanis Advanced Engineering Electromagnetics , 1989 .