The biomechanics of the human patella during passive knee flexion.

The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.

[1]  P. Maquet [Biomechanics of the patello-femoral joint]. , 1978, Acta orthopaedica Belgica.

[2]  M. Osteaux,et al.  The Knee Joint , 1991 .

[3]  M. Shitikova,et al.  Ray Method for Solving Dynamic Problems Connected With Propagation of Wave Surfaces of Strong and Weak Discontinuities , 1995 .

[4]  P. Alart,et al.  A mixed formulation for frictional contact problems prone to Newton like solution methods , 1991 .

[5]  D. Hungerford,et al.  Disorders of the Patello-femoral Joint , 1977 .

[6]  J H Heegaard,et al.  A finite element model for evaluation of tibial prosthesis-bone interface in total knee replacement. , 1992, Journal of biomechanics.

[7]  A stereophotogrammetric method for measurements of ligament structure. , 1989, Journal of biomechanics.

[8]  P. Abernethy,et al.  A stress analysis of the patella, and how it relates to patellar articular cartilage lesions. , 1979, Journal of biomechanics.

[9]  Musculoskeletal,et al.  Biology and biomechanics of the traumatized synovial joint : the knee as a model , 1992 .

[10]  Y. Mori,et al.  A scanning electron microscopic study of the degenerative cartilage in patellar chondropathy. , 1993, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[11]  R. Rose,et al.  Structure and function of the human patella: the role of cancellous bone. , 1976, Journal of Biomedical Materials Research.

[12]  J R Essinger,et al.  A mathematical model for the evaluation of the behaviour during flexion of condylar-type knee prostheses. , 1989, Journal of biomechanics.

[13]  A. Curnier Tact: A Contact Analysis Program , 1987 .

[14]  A. M. Ahmed,et al.  In-vitro measurement of static pressure distribution in synovial joints--Part II: Retropatellar surface. , 1983, Journal of biomechanical engineering.

[15]  W C Hayes,et al.  Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact. , 1984, The Journal of bone and joint surgery. American volume.

[16]  M. Gurtin,et al.  An introduction to continuum mechanics , 1981 .

[17]  Wilson C. Hayes,et al.  Basic Orthopaedic Biomechanics , 1995 .

[18]  J A Sevastikoglou,et al.  Evaluation of the reliability of radiological methods for registration of scoliosis. , 1969, Acta orthopaedica Scandinavica.

[19]  A. M. Ahmed,et al.  Force analysis of the patellar mechanism , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  T D Brown,et al.  Some effects of global joint morphology on local stress aberrations near imprecisely reduced intra-articular fractures. , 1990, Journal of biomechanics.

[21]  J H Heegaard,et al.  Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component. , 1993, Journal of biomechanics.

[22]  Clifford Ambrose Truesdell,et al.  A first course in rational continuum mechanics , 1976 .

[23]  Hwj Rik Huiskes Mathematical modeling of the knee , 1992 .

[24]  Mohamed Samir Hefzy,et al.  Review of Knee Models , 1988 .

[25]  F. Zajac,et al.  A planar model of the knee joint to characterize the knee extensor mechanism. , 1989, Journal of biomechanics.

[26]  E Y Chao,et al.  A survey of finite element analysis in orthopedic biomechanics: the first decade. , 1983, Journal of biomechanics.

[27]  R. E. Outerbridge,et al.  The problem of chondromalacia patellae. , 1975, Clinical orthopaedics and related research.

[28]  V Wright,et al.  Mechanical factors and patellofemoral osteoarthrosis. , 1979, Annals of the rheumatic diseases.

[29]  B. Reider,et al.  Patellar tracking. , 1981, Clinical orthopaedics and related research.

[30]  H Weinans,et al.  Trends of mechanical consequences and modeling of a fibrous membrane around femoral hip prostheses. , 1990, Journal of biomechanics.

[31]  A. Curnier,et al.  A finite element method for a class of contact-impact problems , 1976 .

[32]  B B Seedhom,et al.  Biomechanics of the patello-femoral joint. Part I: A study of the contact and the congruity of the patello-femoral compartment and movement of the patella. , 1983, Engineering in medicine.

[33]  S. Hirokawa,et al.  Three-dimensional mathematical model analysis of the patellofemoral joint. , 1991, Journal of biomechanics.

[34]  L Blankevoort,et al.  Ligament-bone interaction in a three-dimensional model of the knee. , 1991, Journal of biomechanical engineering.

[35]  A. Kampen,et al.  The three-dimensional tracking pattern of the patella: in vitro analysis , 1987 .

[36]  Richard H. Gallagher,et al.  Finite Elements in Biomechanics , 1982 .

[37]  M Heller,et al.  Patellar tracking patterns during active and passive knee extension: evaluation with motion-triggered cine MR imaging. , 1993, Radiology.

[38]  Docteur Paul G. J. Maquet,et al.  Biomechanics of the Knee , 1984, Springer Berlin Heidelberg.

[39]  D. Kettelkamp,et al.  The effect of patellectomy on knee function. , 1976, The Journal of bone and joint surgery. American volume.

[40]  H. Kaufer Mechanical function of the patella. , 1971, The Journal of bone and joint surgery. American volume.

[41]  J. Z. Zhu,et al.  The finite element method , 1977 .

[42]  E. Reithmeier,et al.  A theoretical and numerical approach to optimal positioning of the patellar surface replacement in a total knee endoprosthesis. , 1990, Journal of biomechanics.

[43]  D. J. Rapperport,et al.  Contact finite element stress analysis of porous ingrowth acetabular cup implantation, ingrowth, and loosening , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[44]  V. Mow,et al.  Stereophotogrammetric Determination of Joint Anatomy and Contact Areas , 1990 .

[45]  P. Ficat Pathologie fémoro-patellaire , 1970 .

[46]  A. Curnier Computational methods in solid mechanics , 1994 .

[47]  I. Watt,et al.  The importance of femoral rotation in chondromalacia patellae as shown by serial radiography. , 1979, The Journal of bone and joint surgery. British volume.

[48]  T. van Eijden,et al.  A mathematical model of the patellofemoral joint. , 1986, Journal of biomechanics.

[49]  Robert L. Spilker,et al.  A penalty finite element analysis for nonlinear mechanics of biphasic hydrated soft tissue under large deformation , 1991 .

[50]  L. S. Matthews,et al.  Patellar surface strain , 1986, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[51]  M. Martens,et al.  Experimental analysis of the quadriceps muscle force and patello-femoral joint reaction force for various activities. , 1972, Acta orthopaedica Scandinavica.

[52]  I. S. Tuba,et al.  A finite element method for contact problems of solid bodies—Part II. Application to turbine blade fastenings , 1971 .

[53]  K Rim,et al.  Stresses in the human knee joint. , 1976, Journal of biomechanics.

[54]  B. Seedhom,et al.  An Evaluation of the Ratio between the Tensions along the Quadriceps Tendon and the Patellar Ligament , 1980 .

[55]  G. Selvik Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. , 1989, Acta orthopaedica Scandinavica. Supplementum.

[56]  A J Cox,et al.  Biomechanics of the patello-femoral joint. , 1990, Clinical biomechanics.

[57]  S Hirokawa Biomechanics of the knee joint: a critical review. , 1993, Critical reviews in biomedical engineering.

[58]  J O Galante,et al.  Model studies of the stiffness characteristics of the human knee joint. , 1983, Journal of biomechanics.

[59]  Stress trajectories in the patella. Study by the photoelastic method. , 1970, Acta orthopaedica Scandinavica.

[60]  S. Chan,et al.  A finite element method for contact problems of solid bodies—Part I. Theory and validation , 1971 .

[61]  Freddie H. Fu,et al.  Relief of patellofemoral contact stress by anterior displacement of the tibial tubercle. , 1979, The Journal of bone and joint surgery. American volume.

[62]  W. Hayes,et al.  Force ratios in the quadriceps tendon and ligamentum patellae , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[63]  R Huiskes,et al.  The three‐dimensional tracking pattern of the human patella , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[64]  A. Curnier,et al.  An augmented Lagrangian method for discrete large‐slip contact problems , 1993 .

[65]  L. S. Matthews,et al.  Load bearing characteristics of the patello-femoral joint. , 1977, Acta orthopaedica Scandinavica.

[66]  D. Carter,et al.  Theoretical stress analysis of organ culture osteogenesis. , 1990, Bone.

[67]  J Wismans,et al.  A three-dimensional mathematical model of the knee-joint. , 1980, Journal of biomechanics.

[68]  F Eckstein,et al.  Distribution of subchondral bone density and cartilage thickness in the human patella. , 1992, Journal of anatomy.

[69]  J. P. Paul,et al.  Biomechanics , 1966 .

[70]  J. Goodfellow,et al.  Patello-femoral joint mechanics and pathology. 1. Functional anatomy of the patello-femoral joint. , 1976, The Journal of bone and joint surgery. British volume.