Simple immunoassay for detection of PCBs in transformer oil.

A rapid and inexpensive procedure to detect polychlorinated biphenyls (PCBs) in transformer oil is needed to facilitate identification and removal of PCB contaminated transformers. Here we describe a simple two-step liquid-liquid extraction using acidic dimethyl sulfoxide in conjunction with an immunoassay for detecting PCBs in transformer oil. The process described is faster and simpler than any previous immunoassay while maintaining comparable detection limit and false negative rate. Cross reactivity data, characterizing the immunoassay response to the four Kanechlor technical mixtures of PCBs in oil, are presented. Forty-five used transformer oil samples were analyzed by gas chromatography-high-resolution mass spectrometry and were also evaluated using the immunoassay protocol developed. Results presented show zero false negatives at a 1.4 ppm nominal cutoff for the transformer oils analyzed.

[1]  T. Nguyen,et al.  Near real-time biosensor-based detection of 2,4-dinitrophenol. , 2003, Biosensors & bioelectronics.

[2]  D. Wylie,et al.  Metal Binding Properties of a Monoclonal Antibody Directed toward Metal-Chelate Complexes* , 1996, The Journal of Biological Chemistry.

[3]  J. L. Zajicek,et al.  Comparison of an enzyme-linked immunosorbent assay (ELISA) to gas chromatography (GC)--measurement of polychlorinated biphenyls (PCBs) in selected US fish extracts. , 2000, Chemosphere.

[4]  Ya-Wen Chiu,et al.  Selective binding of polychlorinated biphenyl congeners by a monoclonal antibody: analysis by kinetic exclusion fluorescence immunoassay. , 2001, Analytical chemistry.

[5]  H. Saiki,et al.  An immunoassay for small analytes with theoretical detection limits. , 2001, Analytical Chemistry.

[6]  R. Blake,et al.  Automated kinetic exclusion assays to quantify protein binding interactions in homogeneous solution. , 1999, Analytical biochemistry.

[7]  Hiroshi Saiki,et al.  Combinational use of antibody affinities in an immunoassay for extension of dynamic range and detection of multiple analytes. , 2003, Analytical chemistry.

[8]  H. Saiki,et al.  Development and characterization of new monoclonal antibodies specific for coplanar polychlorinated biphenyls , 2004 .

[9]  C von Holst,et al.  Use of an immunoassay as a means to detect polychlorinated biphenyls in animal fat , 2001, Food additives and contaminants.

[10]  A E Karu,et al.  A monoclonal immunoassay for the coplanar polychlorinated biphenyls. , 1995, Analytical chemistry.