Windowless ultrasound photoacoustic cell for in vivo mid-IR spectroscopy of human epidermis: low interference by changes of air pressure, temperature, and humidity caused by skin contact opens the possibility for a non-invasive monitoring of glucose in the interstitial fluid.

The application of a novel open, windowless cell for the photoacoustic infrared spectroscopy of human skin is described. This windowless cavity is tuned for optimum performance in the ultrasound range between 50 and 60 kHz. In combination with an external cavity tunable quantum cascade laser emitting in the range from ~1000 cm(-1) to 1245 cm(-1), this approach leads to high signal-to-noise-ratio (SNR) for mid-infrared spectra of human skin. This opens the possibility to measure in situ the absorption spectrum of human epidermis in the mid-infrared region at high SNR in a few (~5) seconds. Rapid measurement of skin spectra greatly reduces artifacts arising from movements. As compared to closed resonance cells, the windowless cell exhibits the advantage that the influence of air pressure variations, temperature changes, and air humidity buildup that are caused by the contact of the cell to the skin surface can be minimized. We demonstrate here that this approach can be used for continuous and non-invasive monitoring of the glucose level in human epidermis, and thus may form the basis for a non-invasive monitoring of the glucose level for diabetes patients.

[1]  Markus W. Sigrist,et al.  Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications , 2013, Sensors.

[2]  Infrared spectroscopy in hemodialysis: reagent-free monitoring of patient detoxification by infrared spectroscopy , 2012, Analytical and Bioanalytical Chemistry.

[3]  Werner Mäntele,et al.  Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy , 2011 .

[4]  Gerd Köhler,et al.  Bedside monitoring of subcutaneous interstitial glucose in healthy individuals using microdialysis and infrared spectrometry. , 2007, Journal of biomedical optics.

[5]  M. Sigrist,et al.  New photoacoustic cell design for studying aqueous solutions and gels. , 2011, The Review of scientific instruments.

[6]  G. B. Christison,et al.  Laser photoacoustic determination of physiological glucose concentrations in human whole blood , 1993, Medical and Biological Engineering and Computing.

[7]  Shape-Optimized Photoacoustic Cell: Numerical Consolidation and Experimental Confirmation , 2012 .

[8]  C. Toumazou,et al.  Glucose sensors: a review of current and emerging technology , 2009, Diabetic medicine : a journal of the British Diabetic Association.

[9]  Zoltán Bozóki,et al.  Photoacoustic Instruments for Practical Applications: Present, Potentials, and Future Challenges , 2011 .

[10]  A. Miklós,et al.  Calibration of a windowless photoacoustic cell for detection of trace gases , 1992 .

[11]  Werner Mäntele,et al.  Clinical chemistry without reagents? An infrared spectroscopic technique for determination of clinically relevant constituents of body fluids , 2007, Analytical and bioanalytical chemistry.

[12]  Eigenmode analysis of photoacoustic sensors via finite element method , 2006 .

[13]  Allen Gersho,et al.  Theory of the photoacoustic effect with solids , 1975 .

[14]  Werner Mäntele,et al.  A novel approach to non-invasive glucose measurement by mid-infrared spectroscopy: The combination of quantum cascade lasers (QCL) and photoacoustic detection , 2005 .

[15]  Benli Yu,et al.  Recent Progress on Infrared Photoacoustic Spectroscopy Techniques , 2011 .

[16]  Kirk H. Michaelian Photoacoustic Infrared Spectroscopy: Michaelian/Infrared Spectroscopy , 2005 .

[17]  András Miklós,et al.  Windowless resonant acoustic chamber for laser-photoacoustic applications , 1989 .

[18]  Christoph Haisch,et al.  Photoacoustic spectroscopy for analytical measurements , 2011 .

[19]  D. B. Keenan,et al.  Putative Delays in Interstitial Fluid (ISF) Glucose Kinetics Can Be Attributed to the Glucose Sensing Systems Used to Measure Them Rather than the Delay in ISF Glucose Itself , 2007, Journal of diabetes science and technology.

[20]  Werner Mäntele,et al.  In vivo noninvasive monitoring of glucose concentration in human epidermis by mid-infrared pulsed photoacoustic spectroscopy. , 2013, Analytical chemistry.

[21]  K. Michaelian,et al.  Dual beam photoacoustic infrared spectroscopy of solids using an external cavity quantum cascade laser. , 2012, The Review of scientific instruments.

[22]  J Kost,et al.  Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels. , 2000, Journal of applied physiology.

[23]  Patrick Garidel,et al.  Mid-FTIR-Microspectroscopy of stratum corneum single cells and stratum corneum tissue , 2002 .

[24]  Markus W. Sigrist,et al.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection , 2012, Biomedical optics express.

[25]  A. Baillet,et al.  ATR-FTIR spectroscopy: a chemometric approach for studying the lipid organisation of the stratum corneum. , 2005, Chemistry and physics of lipids.

[26]  M. Wolff,et al.  Finite element calculation of photoacoustic signals. , 2007, Applied optics.