The role of robotic endovascular catheters in fenestrated stent grafting.

OBJECTIVE Fenestrated stent grafting has allowed the treatment of complex thoraco-abdominal aneurysm disease via a totally endovascular approach, but the procedure can be technically challenging and time consuming. We investigated whether this procedure may be enhanced by remotely steerable robotic endovascular catheters. METHODS A four-vessel fenestrated stent graft partially deployed within a computed tomography (CT)-reconstructed pulsatile thoraco-abdominal aneurysm silicon model was used. Fifteen operators were recruited to participate in the study and divided into three groups, based on their endovascular experience: group A (n = 4, 100-200 endovascular procedures, group B (n = 5, 200-300), and group C (n = 6, >300). All operators were asked to cannulate the renal and visceral vessels under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times and wire/catheter tip movements) and qualitative metrics (procedure-specific-rating scale [IC3ST]), which grades operators on catheter use, instrumentation, successful cannulation/catheterization, and overall performance were compared. RESULTS Median procedure time for cannulation of all four vessels was reduced using the robotic system (2.87 min, interquartile range [IQR; 2.20-3.90] versus 17.24 min [11.90-19.80]; P < .001) for each individual operator, regardless of the level of endovascular experience. The total number of wire/catheter movements taken to complete the task was also significantly reduced (38, IQR [29-57] versus 454 [283-687]; P < .001). There were significant differences in time and movement for cannulation of each individual vessel in the phantom. Robotic catheter operator radiation exposure was negligible as the robotic workstation is remote and away from the radiation source. Overall performance scores significantly improved using the robotic system, despite minimal operator exposure to this technology (IC3ST score 29/35, IQR [22.8-30.7] versus 19/35 [13-24.3]; P = .002). Each group of operators demonstrated an improvement in performance with robotic cannulation. For group A, median IC3ST score was 28/35, IQR (22-33) versus 15/35 (11-20); P = .04; for group B, 30/35 (27-31) versus 19/35 (18-24); P = .07; and for group C, 28.8/35 (28.5-29) versus 22/35 (16-24); P = .06. For groups B and C, these differences did not reach statistical significance. CONCLUSION Robotic catheterization of target vessels during this procedure is feasible and minimizes radiation exposure for the operator. Steerable robotic catheters with intuitive control may overcome some of the limitations of standard catheter technology, enhance target vessel cannulation, reduce instrumentation, and improve overall performance scores.

[1]  Rajesh Aggarwal,et al.  Toward Feasible, Valid, and Reliable Video-Based Assessments of Technical Surgical Skills in the Operating Room , 2008, Annals of surgery.

[2]  N. Cheshire,et al.  Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting , 2009, CardioVascular and Interventional Radiology.

[3]  Steven D. Wexner,et al.  The current status of robotic pelvic surgery: results of a multinational interdisciplinary consensus conference , 2009, Surgical Endoscopy.

[4]  A. Darzi,et al.  Experienced endovascular interventionalists objectively improve their skills by attending carotid artery stent training courses. , 2008, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[5]  B. Lytle,et al.  Endovascular Repair of Thoracoabdominal Aneurysms , 2008, Circulation.

[6]  R. Katznelson,et al.  Objective Assessment of Manual Skills and Proficiency in Performing Epidural Anesthesia—Video-Assisted Validation , 2006, Regional Anesthesia & Pain Medicine.

[7]  R. Reznick,et al.  Objective structured assessment of technical skill (OSATS) for surgical residents , 1997, The British journal of surgery.

[8]  Thomas M Krummel,et al.  Simulation-based endovascular skills assessment: the future of credentialing? , 2008, Journal of vascular surgery.

[9]  R. Reznick,et al.  Testing technical skill via an innovative "bench station" examination. , 1997, American journal of surgery.

[10]  J. Brachmann,et al.  Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results. , 2008, Journal of the American College of Cardiology.

[11]  J. Ruskin,et al.  Initial Experience with a Novel Remote‐Guided Magnetic Catheter Navigation System for Left Ventricular Scar Mapping and Ablation in a Porcine Model of Healed Myocardial Infarction , 2007, Journal of cardiovascular electrophysiology.

[12]  S. Haulon,et al.  Primary endovascular repair of juxtarenal aneurysms with fenestrated endovascular grafting. , 2004, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[13]  Nicholas S. Peters,et al.  Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath , 2008, Journal of Interventional Cardiac Electrophysiology.

[14]  A. Almudevar,et al.  Simulator assessment of innate endovascular aptitude versus empirically correct performance. , 2006, Journal of vascular surgery.

[15]  N. Cheshire,et al.  Treatment of complex aneurysmal disease with fenestrated and branched stent grafts. , 2009, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[16]  A Darzi,et al.  Validation of video-based skill assessment in carotid artery stenting. , 2009, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.