DoFP polarimeter based polarization microscope for biomedical applications

Polarization microscope is a useful technique to observe the optical anisotropic nature of biomedical specimens and provide more microstructural information than the conventional microscope. In this paper, we present a division of focal plane (DoFP) polarimeter based polarization microscope which is capable of imaging both the Stokes vector and the 3×4 Mueller matrix. The Mueller matrix measurement can help us completely understand the polarization properties of the sample and the Stokes vector measurement is a simultaneous technology. First, we calibrate a DoFP polarimeter using the polarization data reduction method for accurate Stokes vector measurements. Second, as the Stokes vector computation for all pixels using the calibrated instrument matrix is usually time consuming, we develop a GPU acceleration algorithm for real time Stokes vector calculations. Third, based on the accurate and fast Stokes vector calculation, we present an optimal 4-states of polarization (4-SoP) illumination scheme for Mueller matrix measurement using the DoFP polarimeter. Finally, we demonstrate the biomedical applications of the DoFP polarimeter based polarization microscope. Experiment results show that the characteristic features of many biomedical samples can be observed in the “polarization staining” images using the circularly polarized light as illumination. In this way, combined with GPU acceleration algorithm, the DoFP polarization microscope has the capacity for real time polarization monitoring of dynamic processes in biological samples.

[1]  Robert Weaver,et al.  Rediscovering polarized light microscopy , 2003 .

[2]  Jessica C Ramella-Roman,et al.  Imaging skin pathology with polarized light. , 2002, Journal of biomedical optics.

[3]  Kaushik Balakrishnan,et al.  Polarization microscope using a near infrared full-Stokes imaging polarimeter. , 2015, Optics express.

[4]  Lawrence B. Wolff,et al.  Polarization vision: a new sensory approach to image understanding , 1997, Image Vis. Comput..

[5]  Irving Itzkan,et al.  Multispectral scanning during endoscopy guides biopsy of dysplasia in Barrett's esophagus , 2010, Nature Medicine.

[6]  R. Oldenbourg A new view on polarization microscopy , 1996, Nature.

[7]  Bernard Le Jeune,et al.  Mueller matrix polarimetry for improved liver fibrosis diagnosis. , 2012, Optics letters.

[8]  Nan Zeng,et al.  Differentiating characteristic microstructural features of cancerous tissues using Mueller matrix microscope. , 2015, Micron.

[9]  Cornell S. L. Chun,et al.  Polarization-sensitive thermal imaging sensors for target discrimination , 1998, Defense, Security, and Sensing.

[10]  Viktor Gruev,et al.  Complementary fluorescence-polarization microscopy using division-of-focal-plane polarization imaging sensor , 2012, Journal of biomedical optics.

[11]  J. Tyo Design of optimal polarimeters: maximization of signal-to-noise ratio and minimization of systematic error. , 2002, Applied optics.

[12]  Ji Qi,et al.  Narrow band 3 × 3 Mueller polarimetric endoscopy. , 2013, Biomedical optics express.

[13]  J Scott Tyo,et al.  Interpolation strategies for reducing IFOV artifacts in microgrid polarimeter imagery. , 2009, Optics express.

[14]  Oriol Arteaga,et al.  Mueller matrix microscope with a dual continuous rotating compensator setup and digital demodulation. , 2014, Applied optics.

[15]  Rajesh Kumar,et al.  Mueller matrix three-dimensional directional imaging of collagen fibers , 2014, Journal of biomedical optics.

[16]  Alex Vitkin,et al.  Polarized light imaging in biomedicine: emerging Mueller matrix methodologies for bulk tissue assessment , 2015, Journal of biomedical optics.

[17]  Nan Zeng,et al.  Single-shot spatially modulated Stokes polarimeter based on a GRIN lens. , 2014, Optics letters.

[18]  J. Walsh,et al.  Comparative study of polarized light propagation in biologic tissues. , 2002, Journal of biomedical optics.

[19]  Xia Wang,et al.  Calibration method of microgrid polarimeters with image interpolation. , 2015, Applied optics.

[20]  Valery V. Tuchin,et al.  Tissue Structure and Optical Models , 2006 .

[21]  Nirmalya Ghosh,et al.  Tissue polarimetry: concepts, challenges, applications, and outlook. , 2011, Journal of biomedical optics.

[22]  Nan Zeng,et al.  Linear polarization optimized Stokes polarimeter based on four-quadrant detector. , 2015, Applied optics.

[23]  Ran Liao,et al.  Study on errors of nonsimultaneous polarized-light scattering measurements of suspended rod-shaped particles , 2015 .

[24]  Nan Zeng,et al.  Characterizing microstructures of cancerous tissues using multispectral transformed Mueller matrix polarization parameters. , 2015, Biomedical optics express.