Video-rate tomographic phase microscopy Citation

Tomographic phase microscopy measures the 3-D refractive index distribution of cells and tissues by combining the information from a series of angle-dependent interferometric phase images. In the original device, the frame rate was limited to 0.1 frames per second (fps) by the technique used to acquire phase images, preventing measurements of moving or rapidly changing samples. We describe an improved tomographic phase microscope in which phase images are acquired via a spatial fringe pattern demodulation method, enabling a full tomogram acquisition rate of 30 fps. In addition, in this system the refractive index is calculated by a diffraction tomography algorithm that accounts for the effects of diffraction in the 3-D reconstruction. We use the instrument to quantitatively monitor rapid changes in refractive index within defined subregions of cells due to exposure to acetic acid or changes in medium osmolarity. C ©2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3522506]

[1]  R. Barer Determination of Dry Mass, Thickness, Solid and Water Concentration in Living Cells , 1953, Nature.

[2]  M. Takeda,et al.  Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry , 1982 .

[3]  K. Nugent,et al.  Noninterferometric phase imaging with partially coherent light , 1998 .

[4]  K. Nugent,et al.  Quantitative phase tomography , 2000 .

[5]  R H Smallwood,et al.  A study of the morphological parameters of cervical squamous epithelium. , 2003, Physiological measurement.

[6]  Gabriel Popescu,et al.  Hilbert phase microscopy for investigating fast dynamics in transparent systems. , 2005, Optics letters.

[7]  W. Denk,et al.  Deep tissue two-photon microscopy , 2005, Nature Methods.

[8]  E. Cuche,et al.  Cell refractive index tomography by digital holographic microscopy. , 2006, Optics letters.

[9]  P. Marquet,et al.  Living specimen tomography by digital holographic microscopy: morphometry of testate amoeba. , 2006, Optics express.

[10]  K. Badizadegan,et al.  Live cell refractometry using microfluidic devices. , 2006, Optics letters.

[11]  Michael S Feld,et al.  Imaging voltage-dependent cell motions with heterodyne Mach-Zehnder phase microscopy. , 2007, Optics letters.

[12]  Kamran Badizadegan,et al.  Extended depth of focus in tomographic phase microscopy using a propagation algorithm. , 2008, Optics letters.

[13]  C. Fang-Yen,et al.  Tomographic phase microscopy , 2008, Nature Methods.

[14]  Yongkeun Park,et al.  Refractive index maps and membrane dynamics of human red blood cells parasitized by Plasmodium falciparum , 2008, Proceedings of the National Academy of Sciences.

[15]  O. Haeberlé,et al.  Holographic microscopy and diffractive microtomography of transparent samples , 2008 .

[16]  C. Fang-Yen,et al.  Optical diffraction tomography for high resolution live cell imaging. , 2009, Optics express.