Modiolus-Hugging Intracochlear Electrode Array with Shape Memory Alloy

In the cochlear implant system, the distance between spiral ganglia and the electrodes within the volume of the scala tympani cavity significantly affects the efficiency of the electrical stimulation in terms of the threshold current level and spatial selectivity. Because the spiral ganglia are situated inside the modiolus, the central axis of the cochlea, it is desirable that the electrode array hugs the modiolus to minimize the distance between the electrodes and the ganglia. In the present study, we propose a shape-memory-alloy-(SMA-) embedded intracochlear electrode which gives a straight electrode a curved modiolus-hugging shape using the restoration force of the SMA as triggered by resistive heating after insertion into the cochlea. An eight-channel ball-type electrode array is fabricated with an embedded titanium-nickel SMA backbone wire. It is demonstrated that the electrode array changes its shape in a transparent plastic human cochlear model. To verify the safe insertion of the electrode array into the human cochlea, the contact pressures during insertion at the electrode tip and the contact pressures over the electrode length after insertion were calculated using a 3D finite element analysis. The results indicate that the SMA-embedded electrode is functionally and mechanically feasible for clinical applications.

[1]  M. Merzenich,et al.  Strategies to improve electrode positioning and safety in cochlear implants , 1999, IEEE Transactions on Biomedical Engineering.

[2]  Stephen J. Rebscher,et al.  A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion™ and HiFocus II™ electrodes , 2005, Hearing Research.

[3]  A. Eshraghi,et al.  Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs , 2003, The Laryngoscope.

[4]  Sung June Kim,et al.  Three-dimensional analysis of electrode behavior in a human cochlear model. , 2005, Medical engineering & physics.

[5]  A. Hodges,et al.  Novel Intracochlear Electrode Positioner: Effects on Electrode Position , 2000, The Annals of otology, rhinology & laryngology. Supplement.

[6]  Stephen J. Rebscher,et al.  Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion. , 2008, Journal of rehabilitation research and development.

[7]  S. Yim,et al.  Finite element modeling of reinforced concrete structures strengthened with FRP laminates : final report. , 2001 .

[8]  D W Kennedy,et al.  Multichannel intracochlear electrodes: Mechanism of insertion trauma , 1987, The Laryngoscope.

[9]  T. Tadaki,et al.  Shape Memory Alloys , 2002 .

[10]  B J Gantz,et al.  Insertional trauma of multichannel cochlear implants , 1993, The Laryngoscope.

[11]  Van Krevelen Properties of Polymers: Their Correlation with Chemical Structure; their Numerical Estimation and Prediction from Additive Group Contributions , 2009 .

[12]  K. Mazanec,et al.  Structure and surface of TiNi human implants. , 2001, Biomaterials.

[13]  Peter S Roland,et al.  Surgical aspects of cochlear implantation: mechanisms of insertional trauma. , 2006, Advances in oto-rhino-laryngology.

[14]  W S Rhode Cochlear mechanics. , 1984, Annual review of physiology.

[15]  K. Horch,et al.  Mechanical testing of metallic and polymeric intrafascicular electrodes , 1994, Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Stephen J. Rebscher,et al.  A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour ™ electrodes , 2005, Hearing Research.

[17]  L. Schetky Shape-memory alloys , 1979 .

[18]  G. Bredberg,et al.  Meningitis following Cochlear Implantation: Pathomechanisms, Clinical Symptoms, Conservative and Surgical Treatments , 2002, ORL.

[19]  A. Bacciu,et al.  The Nucleus Contour Electrode Array: An Electrophysiological Study , 2002, The Laryngoscope.