Static coating of 5 to 50 μm I.D. capillary columns for open tubular column chromatography

Abstract Dichlorofluoromethane, trichlorofluoromethane and tetramethylsilane were used in the static coating of small diameter capillary columns (5 to 50 μm I.D.) in order to obtain highly efficient columns for gas and supercritical fluid chromatography. Capillary columns of 5-, 10-, 25-, and 50-μm I.D. were coated with stationary phase films of SE-33, SE-54, OV-215, 50% n-octyl, 45% phenoxypolyethyl ether, 50% liquid crystal, 25% biphenyl, 50% pentafluorophenyl and 50% cyanopropyl polysiloxane stationary phases. Resultant evaluations of these columns in gas chromatography gave approximately 9000, 66 000, 45 000, and 19 000 plates m−1, respectively, for the different internal diameters. Important parameters which affect coating efficiency are identified and discussed in detail.

[1]  G. Rutten,et al.  Analysis of steroids by high resolution gas-liquid chromatography. I. Preparation of apolar columns. , 1972, Journal of chromatography.

[2]  K. Markides,et al.  Synthesis and chromatographic properties of polysiloxane stationary phases containing biphenylcarboxylate ester liquid-crystalline side groups , 1986 .

[3]  M. Lee,et al.  Static coating of capillary columns using mixed solvents , 1983 .

[4]  N. Vermeulen,et al.  Free release static coating of glass capillary columns; Static coating at elevated pressure — Theoretical considerations and practice , 1984 .

[5]  Mary T. Gilbert,et al.  Kinetic optimization of straight open-tubular liquid chromatography , 1979 .

[6]  Milton L. Lee,et al.  Theoretical treatment of resolving power in open tubular column supercritical fluid chromatography , 1983 .

[7]  J. Jorgenson,et al.  Characterization of an on-column electrochemical detector for open-tubular liquid chromatography , 1985 .

[8]  Ja Jacques Rijks,et al.  Increased speed of analysis in isothermal and temperature-programmed capillary gas chromatography by reduction of the column inner diameter , 1982 .

[9]  K. Markides,et al.  Comparison of oligo(ethylene oxide)-substituted polysiloxanes with poly(ethylene glycol) as stationary phases for capillary chromatography , 1988 .

[10]  K. Markides,et al.  n-Octylmethylpolysiloxane stationary phase for capillary column gas and supercritical fluid chromatography , 1985 .

[11]  Frank J. Yang Open Tubular Column LC: Theory and Practice , 1982 .

[12]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[13]  B. Goodwin Static coating of capillary columns: Some practical considerations , 1979 .

[14]  Milton L. Lee,et al.  Preparation of small-diameter capillary columns for gas and supercritical fluid chromatography , 1984 .

[15]  M. Lee,et al.  Nonextractable cyanopropyl polysiloxane stationary phases for capillary chromatography , 1983 .

[16]  J. Giddings Role of Column Pressure Drop in Gas Chromatographic Resolution. , 1964 .

[17]  K. Markides,et al.  New polar substituted-phenyl siloxane monomers and polymers for capillary gas chromatography , 1986 .

[18]  G. Alexander,et al.  Method for preparing glass capillary columns for gas chromatography , 1974 .

[19]  G. Guiochon Conventional packed columns vs. packed or open tubular microcolumns in liquid chromatography , 1981 .

[20]  J. Schrauwen Entfernung der Untergrund-Färbung nach Disc-Elektrophorese , 1964 .

[21]  K. Markides,et al.  Liquid sample introduction methods in capillary column supercritical fluid chromatography , 1989 .