Motor threshold in transcranial magnetic stimulation: The impact of white matter fiber orientation and skull‐to‐cortex distance

The electrophysiology of transcranial magnetic stimulation (TMS) of motor cortex is not well understood. In this study, we investigate several structural parameters of the corticospinal tract and their relation to the TMS motor threshold (MT) in 17 subjects, with and without schizophrenia. We obtained structural and diffusion tensor MRI scans and measured the fractional anisotropy and principal diffusion direction for regions of interest in the corticospinal tract. We also measured the skull‐to‐cortex distance over the left motor region. The anterior–posterior trajectory of principle diffusion direction of the corticospinal tract and skull‐to‐cortex distance were both found to be highly correlated with MT, while fractional anisotropy, age and schizophrenia status were not. Two parameters—skull‐to‐cortex distance and the anterior component of the principle diffusion direction of the corticospinal tract as it passes the internal capsule—are highly predictive of MT in a linear regression model, and account for 82% of the variance observed (R2 = 0.82, F = 20.27, P < 0.0001) in measurements of MT. The corticospinal tract's anterior–posterior direction alone contributes 13% of the variance explained. Hum Brain Mapp, 2009. © 2008 Wiley‐Liss, Inc.

[1]  Jerry L. Prince,et al.  Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T , 2007, NeuroImage.

[2]  Robert Chen,et al.  Interhemispheric inhibition in distal and proximal arm representations in the primary motor cortex. , 2007, Journal of neurophysiology.

[3]  R. Kikinis,et al.  A review of diffusion tensor imaging studies in schizophrenia. , 2007, Journal of psychiatric research.

[4]  Daniel Rueckert,et al.  Tract-based spatial statistics: Voxelwise analysis of multi-subject diffusion data , 2006, NeuroImage.

[5]  Tracy R. Henderson,et al.  Simple metric for scaling motor threshold based on scalp-cortex distance: application to studies using transcranial magnetic stimulation. , 2005, Journal of neurophysiology.

[6]  Roland Bammer,et al.  Occipital‐Callosal Pathways in Children: Validation and Atlas Development , 2005, Annals of the New York Academy of Sciences.

[7]  R. Dougherty,et al.  Cross‐subject comparison of principal diffusion direction maps , 2005, Magnetic resonance in medicine.

[8]  Mark W. Woolrich,et al.  Advances in functional and structural MR image analysis and implementation as FSL , 2004, NeuroImage.

[9]  Jejo D. Koola,et al.  The Maximum-likelihood Strategy for Determining Transcranial Magnetic Stimulation Motor Threshold, Using Parameter Estimation by Sequential Testing Is Faster Than Conventional Methods With Similar Precision , 2004, The journal of ECT.

[10]  K. Krishnan,et al.  Diffusion tensor imaging: background, potential, and utility in psychiatric research , 2003, Biological Psychiatry.

[11]  S. Wakana,et al.  Fiber tract-based atlas of human white matter anatomy. , 2004, Radiology.

[12]  Robert Chen,et al.  Organization of ipsilateral excitatory and inhibitory pathways in the human motor cortex. , 2003, Journal of neurophysiology.

[13]  F. Awiszus TMS and threshold hunting. , 2003, Supplements to Clinical neurophysiology.

[14]  J. Lorberbaum,et al.  The transcranial magnetic stimulation motor threshold depends on the distance from coil to underlying cortex: a replication in healthy adults comparing two methods of assessing the distance to cortex , 2001, Biological Psychiatry.

[15]  J. Lorberbaum,et al.  How coil-cortex distance relates to age, motor threshold, and antidepressant response to repetitive transcranial magnetic stimulation. , 2000, The Journal of neuropsychiatry and clinical neurosciences.

[16]  H. Axer,et al.  Mapping of fiber orientation in human internal capsule by means of polarized light and confocal scanning laser microscopy , 2000, Journal of Neuroscience Methods.

[17]  J C Rothwell,et al.  Comparison of descending volleys evoked by transcranial magnetic and electric stimulation in conscious humans. , 1998, Electroencephalography and clinical neurophysiology.

[18]  P. Basser,et al.  A simplified method to measure the diffusion tensor from seven MR images , 1998, Magnetic resonance in medicine.

[19]  P M Rossini,et al.  Interhemispheric differences of hand muscle representation in human motor cortex , 1997, Muscle & nerve.

[20]  K. Mills,et al.  Corticomotor threshold to magnetic stimulation: Normal values and repeatability , 1997, Muscle & nerve.

[21]  H. Alkadhi,et al.  Localization of the motor hand area to a knob on the precentral gyrus. A new landmark. , 1997, Brain : a journal of neurology.

[22]  K Kaneko,et al.  The effect of current direction induced by transcranial magnetic stimulation on the corticospinal excitability in human brain. , 1996, Electroencephalography and clinical neurophysiology.

[23]  B. Steinhoff,et al.  Effects of antiepileptic drugs on motor cortex excitability in humans: A transcranial magnetic stimulation study , 1996, Annals of neurology.

[24]  F Grandori,et al.  Transverse-field activation mechanism in magnetic stimulation of peripheral nerves. , 1996, Electroencephalography and clinical neurophysiology.

[25]  P. Appelbaum,et al.  Constructing competence: formulating standards of legal competence to make medical decisions. , 1996, Rutgers law review.

[26]  P. Ravazzani,et al.  An analytical model to predict the electric field and excitation zones due to magnetic stimulation of peripheral nerves , 1995, IEEE Transactions on Biomedical Engineering.

[27]  M. Stuchly,et al.  Modeling of magnetic field stimulation of bent neurons , 1994, IEEE Transactions on Biomedical Engineering.

[28]  P. Rossini,et al.  Non-invasive electrical and magnetic stimulation of the brain, spinal cord and roots: basic principles and procedures for routine clinical application. Report of an IFCN committee. , 1994, Electroencephalography and clinical neurophysiology.

[29]  M. Hallett,et al.  Differentiation of sensorimotor neuronal structures responsible for induction of motor evoked potentials, attenuation in detection of somatosensory stimuli, and induction of sensation of movement by mapping of optimal current directions. , 1994, Electroencephalography and clinical neurophysiology.

[30]  M. Hallett,et al.  Non-invasive differentiation of motor cortical representation of hand muscles by mapping of optimal current directions. , 1994, Electroencephalography and clinical neurophysiology.

[31]  V. Amassian,et al.  Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation. , 1993, The Journal of physiology.

[32]  V. Amassian,et al.  Modelling magnetic coil excitation of human cerebral cortex with a peripheral nerve immersed in a brain-shaped volume conductor: the significance of fiber bending in excitation. , 1992, Electroencephalography and clinical neurophysiology.

[33]  Basic mechanisms of magnetic coil excitation of nervous system in humans and monkeys and their applications , 1988, Proceedings of a Special Symposium on Maturing Technologies and Emerging Horizons in Biomedical Engineering..

[34]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.