Point-of-entry adsorbers for the removal of fumigants

Point-of-entry systems with granular activated carbon filters have been used extensively to provide safe water to rural homes with wells contaminated with synthetic organic chemicals. Because of the low cost of these systems, their design is generally based on the equilibrium column model, the isotherm data from the literature, and a scale-up factor. This paper analyzes the necessary scale-up factors for point-of-entry adsorbers based on fumigant adsorption data gathered through an extensive literature review. The fumigants evaluated are 1,2-dichloropropane, 1,2-dibromo-3-chloropropane, and ethylene dibromide. It was impossible to thoroughly assess the scale-up factors for 1,2-dichloropropane because of the limited data. Column data for the other two fumigants were sufficient to generate column loading lines, which can be used directly without resorting to scale-up factors. Column data showed that the scale-up factors are greatly affected by competitive adsorption with the naturally occurring background o...