This study aims to investigate the potential of using polymer multi-material additive manufacturing (MMAM) to produce miniature hydraulic piston actuators combining rigid structures and flexible seals. Such actuators offer great potential for medical robots in X-ray and magnetic resonance environments, where conventional piston actuators cannot be used because of safety issues caused by metal components.,Hydraulic pistons with two different integrated flexible seal shapes are designed and manufactured using MMAM. Design 1 features a ring-shaped seal made from a flexible material that is printed on the surface of the rigid piston shaft. Design 2 appears identical from the outside, yet an axial opening in the piston shaft is added to enable self-reinforced sealing as fluid pressure increases. For both designs, samples with three different outer diameters are fabricated leading to a total of six different piston versions. The pistons are then evaluated regarding leakage, friction and durability.,Measurement results show that the friction force for Design 2 is lower than that of Design 1, making Design 2 more suitable for the intended application. None of the versions of Design 2 shows leakage for pressures up to 1.5 MPa. For Design 1, leak-tightness varies with the outer diameter, yet none of the versions is consistently leak-tight at 1.5 MPa. Furthermore, the results show that prolonged exposure to water decreases the durability of the flexible material significantly. The durability the authors observe may, however, be sufficient for short-term or single-use devices.,The authors investigate a novel design approach for hydraulic piston actuators based on MMAM. These actuators are of particular interest for patient-specific medical devices used in radiological interventions, where metal-free components are required to safely operate in X-ray and magnetic resonance environments. This study may serve as a basis for the development of new actuators, as it shows a feasible solution, yet pointing out critical aspects such as the influence of small geometry changes or material performance changes caused by water absorption.
[1]
R. Riener,et al.
Comparison of MRI-Compatible Mechatronic Systems With Hydrodynamic and Pneumatic Actuation
,
2008,
IEEE/ASME Transactions on Mechatronics.
[2]
Kevin Cleary,et al.
MRI Robots for Needle-Based Interventions: Systems and Technology
,
2018,
Annals of Biomedical Engineering.
[3]
Luis Matey,et al.
PolyJet technology for product prototyping: Tensile strength and surface roughness properties
,
2014
.
[4]
Mohieddine Jelali,et al.
Hydraulic Servo-systems: Modelling, Identification and Control
,
2012
.
[5]
Christopher B. Williams,et al.
Fatigue Characterization of 3D Printed Elastomer Material
,
2012
.
[6]
Pierre Renaud,et al.
A 3D-Printed Needle Driver Based on Auxetic Structure and Inchworm Kinematics
,
2018,
Volume 5A: 42nd Mechanisms and Robotics Conference.
[7]
Arnaud Bruyas,et al.
Design and Modeling of a Large Amplitude Compliant Revolute Joint: The Helical Shape Compliant Joint
,
2015
.
[8]
Rob N. Candler,et al.
Characterization of 3D-printed microfluidic chip interconnects with integrated O-rings
,
2014
.
[9]
Gabor Fichtinger,et al.
MRI Compatibility of Robot Actuation Techniques - A Comparative Study
,
2008,
MICCAI.
[10]
Michael J. Lee,et al.
The Provision of Interventional Radiology Services in Europe: CIRSE Recommendations
,
2016,
CardioVascular and Interventional Radiology.
[11]
Czesław Kundera,et al.
Investigating the stress relaxation of photopolymer O-ring seal models
,
2014
.