Regularization design for high-quality cone-beam CT of intracranial hemorrhage using statistical reconstruction

Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentially well suited to deployment at the point of care outside standard diagnostic radiology and emergency room settings. Previous studies have suggested reliable detection of ICH down to 3 mm in CBCT using high-fidelity artifact correction and penalized weighted least-squared (PWLS) image reconstruction with a post-artifact-correction noise model. However, ICH reconstructed by traditional image regularization exhibits nonuniform spatial resolution and noise due to interaction between the statistical weights and regularization, which potentially degrades the detectability of ICH. In this work, we propose three regularization methods designed to overcome these challenges. The first two compute spatially varying certainty for uniform spatial resolution and noise, respectively. The third computes spatially varying regularization strength to achieve uniform "detectability," combining both spatial resolution and noise in a manner analogous to a delta-function detection task. Experiments were conducted on a CBCT test-bench, and image quality was evaluated for simulated ICH in different regions of an anthropomorphic head. The first two methods improved the uniformity in spatial resolution and noise compared to traditional regularization. The third exhibited the highest uniformity in detectability among all methods and best overall image quality. The proposed regularization provides a valuable means to achieve uniform image quality in CBCT of ICH and is being incorporated in a CBCT prototype for ICH imaging.

[1]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[2]  W Zbijewski,et al.  Task-Based Regularization Design for Detection of Intracranial Hemorrhage in Cone-Beam CT. , 2016, Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography.

[3]  Richard M. Leahy,et al.  Resolution and noise properties of MAP reconstruction for fully 3-D PET , 2000, IEEE Transactions on Medical Imaging.

[4]  R. Keep,et al.  Mechanisms of brain injury after intracerebral haemorrhage , 2006, The Lancet Neurology.

[5]  J Yorkston,et al.  High-fidelity artifact correction for cone-beam CT imaging of the brain , 2015, Physics in medicine and biology.

[6]  J Yorkston,et al.  Cone-beam CT of traumatic brain injury using statistical reconstruction with a post-artifact-correction noise model , 2015, Medical Imaging.

[7]  Jeffrey A. Fessler,et al.  Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction , 2000, IEEE Transactions on Medical Imaging.

[8]  J H Siewerdsen,et al.  Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging , 2015, Physics in medicine and biology.

[9]  J. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[10]  Jeffrey A. Fessler,et al.  Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3-D X-ray CT , 2015, IEEE Transactions on Medical Imaging.

[11]  Yoshito Otake,et al.  Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction , 2014, Physics in medicine and biology.

[12]  Max Wintermark,et al.  Imaging of intracranial haemorrhage , 2008, The Lancet Neurology.