Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method.

Bone strength is a fundamental contributor to fracture risk, and with the recent development of in vivo 3D bone micro-architecture measurements by high-resolution peripheral quantitative computed tomography, the finite element (FE) analysis may provide a means to assess patient bone strength in the distal radius. The purpose of this study was to determine an appropriate FE procedure to estimate bone strength by comparison with experimental data. Models based on a homogeneous tissue modulus or a modulus scaled according to computed tomography attenuation were assessed, and these were solved by linear and non-linear FE analyses to estimate strength. The distal radius from fresh, human cadaver forearms (5 male/5 female, ages 55 to 93) was dissected free and four 9.1 mm sections were cut beginning at the subchondral plate to provide 40 test specimens. The sections were scanned using an in vivo protocol providing 3D image data with an 82 microm voxel size. All specimens were mechanically tested in uniaxial compression, and elastic and yield properties were determined. Linear FE analyses were performed on all specimens (N=40), and non-linear analyses using an asymmetric, bilinear yield strain criteria were performed on a sub-sample (N=10) corresponding to the normal clinical measurement site. Experimentally determined apparent elastic properties correlated highly with ultimate stress (R2=0.977, p<0.05, N=31) for the 31 specimens tested to failure. Subsequently, a linear FE analysis estimating apparent elastic properties also correlated highly with failure, and the correlation was higher when moduli were determined from scaled CT-attenuation values than a homogeneous modulus (R2=0.983 vs. R2=0.972, p<0.05, N=31). A non-linear analysis based on tensile and compressive yield strains of 0.0295 and 0.0493 for homogeneous models, and 0.0127 and 0.0212 for scaled models directly estimated ultimate stress, and correlated highly (R2=0.951 vs. R2=0.937, p<0.05, N=5). The linear relation between stiffness and strength may be unique to radius compressive loading. It supports the use of a linear FE analysis to determine bone strength by regression equations established here. Scaled tissue modulus models performed better than homogeneous modulus models, and the advantage of a scaled model is its potential to account for mineralization changes. The combined numerical-experimental procedure for FE model validation on the patient micro-CT technology demonstrated that bone strength can be estimated non-invasively, and this may provide important insight into fracture risk in patient populations.

[1]  R. Huiskes,et al.  Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. , 1996, Journal of biomechanics.

[2]  T M Keaveny,et al.  A cellular solid criterion for predicting the axial-shear failure properties of bovine trabecular bone. , 1999, Journal of biomechanical engineering.

[3]  Thomas N. Hangartner,et al.  Accurate quantification of width and density of bone structures by computed tomography. , 2007 .

[4]  L. Joseph Melton,et al.  Perspective how many women have osteoporosis? , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[5]  G. Niebur,et al.  High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. , 2000, Journal of biomechanics.

[6]  P Rüegsegger,et al.  Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures. , 1995, Medical engineering & physics.

[7]  M. Bouxsein,et al.  In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. , 2005, The Journal of clinical endocrinology and metabolism.

[8]  G. Niebur,et al.  Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. , 2004, Journal of biomechanics.

[9]  P. Delmas,et al.  Microcrack Frequency and Bone Remodeling in Postmenopausal Osteoporotic Women on Long‐Term Bisphosphonates: A Bone Biopsy Study , 2007, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[10]  Ralph Müller,et al.  Mechanical and Architectural Bone Adaptation in Early Stage Experimental Osteoarthritis , 2002, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[11]  T. Keaveny,et al.  Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography. , 2003, Bone.

[12]  Sharmila Majumdar,et al.  A Local Adaptive Threshold Strategy for High Resolution Peripheral Quantitative Computed Tomography of Trabecular Bone , 2007, Annals of Biomedical Engineering.

[13]  J H Keyak,et al.  Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theories. , 2000, Journal of biomechanics.

[14]  T.N. Hangartner,et al.  Image-Based Strength Assessment of Bone , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  P Rüegsegger,et al.  Introduction and evaluation of a gray-value voxel conversion technique. , 2001, Journal of biomechanics.

[16]  P Rüegsegger,et al.  High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo μFE analysis of bone , 2001 .

[17]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[18]  C. Cooper,et al.  Perspective how many women have osteoporosis? , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[19]  Kay Dickersin,et al.  Osteoporosis prevention, diagnosis, and therapy. , 2000, NIH consensus statement.

[20]  F. Eckstein,et al.  Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images. , 2002, Bone.

[21]  N. Kikuchi,et al.  A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress. , 1994, Journal of biomechanics.

[22]  S. Goldstein,et al.  Femoral strength is better predicted by finite element models than QCT and DXA. , 1999, Journal of biomechanics.

[23]  E. Seeman Is a change in bone mineral density a sensitive and specific surrogate of anti-fracture efficacy? , 2007, Bone.

[24]  J. Macneil,et al.  Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. , 2007, Medical engineering & physics.

[25]  Glen L Niebur,et al.  Biaxial failure behavior of bovine tibial trabecular bone. , 2002, Journal of biomechanical engineering.

[26]  Hwj Rik Huiskes,et al.  Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur , 2003, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[27]  M. V. D. van der Meulen,et al.  Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation. , 2004, Journal of biomechanics.

[28]  F. Eckstein,et al.  Image-based micro-finite-element modeling for improved distal radius strength diagnosis: moving from bench to bedside. , 2004, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[29]  A. Burstein,et al.  The elastic and ultimate properties of compact bone tissue. , 1975, Journal of biomechanics.

[30]  Steven K Boyd,et al.  Establishment of an architecture-specific experimental validation approach for finite element modeling of bone by rapid prototyping and high resolution computed tomography. , 2007, Medical engineering & physics.

[31]  Scott J. Hollister,et al.  Digital-image-based finite element analysis for bone microstructure using conjugate gradient and Gaussian filter techniques , 1993, Optics & Photonics.

[32]  B. L. Riggs,et al.  Drugs Used to Treat Osteoporosis: The Critical Need for a Uniform Nomenclature Based on Their Action on Bone Remodeling , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[33]  J. Kanis,et al.  Assessment of fracture risk and its application to screening for postmenopausal osteoporosis: Synopsis of a WHO report , 1994, Osteoporosis International.

[34]  R Poss,et al.  The use of ultrasound in vivo to determine acute change in the mechanical properties of bone following intense physical activity. , 1987, Journal of biomechanics.

[35]  Tatiana Foroud,et al.  Genetics of osteoporosis. , 2002, Endocrine reviews.

[36]  S. Donahue,et al.  Microdamage in bone: implications for fracture, repair, remodeling, and adaptation. , 2006, Critical reviews in biomedical engineering.

[37]  T. Keaveny,et al.  Effects of Teriparatide and Alendronate on Vertebral Strength as Assessed by Finite Element Modeling of QCT Scans in Women With Osteoporosis , 2006, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.