Mechanical resistance of a new biomaterial, ostrich pericardium, and a new method of joining tissues combining suturing and a biological adhesive.
暂无分享,去创建一个
J. G. García Páez | I. Millán | Á. Cordon | A. Rocha | M. Maestro | J. Castillo-olivares | E. Jorge Herrero | José M García Páez | Antonio Carrera Sanmartin | Eduardo Jorge Herrero | Isabel Millán | Angeles Cordón | Aurora Rocha | María A Maestro | Raul Burgos | Gabriel Téllez | José L Castillo-Olivares | A. Carrera Sanmartín | G. Tellez | R. Burgos
[1] Y. Ikada,et al. Bioadhesion of gelatin films crosslinked with glutaraldehyde. , 1999, Journal of biomedical materials research.
[2] W D White,et al. Determinants of reoperation after 960 valve replacements with Carpentier-Edwards prostheses. , 1994, The Journal of thoracic and cardiovascular surgery.
[3] Á. Cordon,et al. Analysis of shearing stress in the limited durability of bovine pericardium used as a biomaterial , 1998, Journal of materials science. Materials in medicine.
[4] D. Quintanar-Guerrero,et al. In vitro evaluation of the bioadhesive properties of hydrophobic polybasic gels containing N,N-dimethylaminoethyl methacrylate-co-methyl methacrylate. , 2001, Biomaterials.
[5] A. Carrera,et al. Mechanical behavior of chemically treated ostrich pericardium subjected to uniaxial tensile testing: influence of the suture. , 2002, Journal of biomedical materials research.
[6] J. M. Bernal,et al. Durability of the Carpentier-Edwards porcine bioprosthesis: role of age and valve position. , 1995, The Annals of thoracic surgery.
[7] J. G. García Páez,et al. Resistance and elasticity of the suture threads employed in cardiac bioprostheses. , 1994, Biomaterials.
[8] J. G. García Páez,et al. Effect of the suture on the durability of bovine pericardium used in cardiac bioprostheses. , 1994, Biomaterials.
[9] J. Monro,et al. Biological valves beyond fifteen years: the Wessex experience. , 1995, The Annals of thoracic surgery.
[10] Richard A. Lange,et al. Prosthetic heart valves. , 1996, The New England journal of medicine.
[11] W. Jamieson,et al. Tricuspid valve replacement: porcine bioprostheses and mechanical prostheses. , 1995, The Annals of thoracic surgery.
[12] Á. Cordon,et al. Comparison of elasticities of components of a cardiac bioprosthesis leaflet. , 1996, Journal of biomedical materials research.
[13] W. Jamieson,et al. Reoperation in biological and mechanical valve populations: fate of the reoperative patient. , 1995, The Annals of thoracic surgery.
[14] R. Goode,et al. Efficacy of octyl-2-cyanoacrylate tissue glue in blepharoplasty. A prospective controlled study of wound-healing characteristics. , 1999, Archives of facial plastic surgery.
[15] J. G. García Páez,et al. Is cutting stress responsible for the limited durability of heart valve bioprostheses? , 1990, The Journal of thoracic and cardiovascular surgery.
[16] Gouri Dhatt,et al. Stress analysis of the human aortic valve , 1973 .
[17] J. G. García Páez,et al. Selection and interaction of biomaterials used in the construction of cardiac bioprostheses. , 1998, Journal of biomedical materials research.
[18] G. Christie,et al. Tears in bioprosthetic heart valve leaflets without calcific degeneration. , 1996, The Journal of heart valve disease.
[19] A. Carrera,et al. Ostrich pericardium, a biomaterial for the construction of valve leaflets for cardiac bioprostheses: mechanical behaviour, selection and interaction with suture materials. , 2001, Biomaterials.
[20] M. Sacks,et al. Collagen fiber architecture of bovine pericardium. , 1994, ASAIO journal.
[21] W. White,et al. In-hospital and long-term outcome after porcine tricuspid valve replacement. , 1995, The Journal of thoracic and cardiovascular surgery.
[22] W. Jamieson,et al. Porcine bioprostheses in the elderly: clinical performance by age groups and valve positions. , 1995, The Annals of thoracic surgery.
[23] J Fisher,et al. Anisotropic elasticity and strength of glutaraldehyde fixed bovine pericardium for use in pericardial bioprosthetic valves. , 1994, Journal of biomedical materials research.
[24] P. Tesar,et al. Late complications of tissue glues in aortic surgery. , 2000, The Annals of thoracic surgery.
[25] W. Edwards,et al. Temporal changes in the surgical pathology of prosthetic aortic valves: a study of 157 cases spanning 26 years (1970-1995). , 1998, Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology.