Preliminary study of clinical outcomes for single implant-retained mandibular overdentures.

This study evaluated marginal bone loss and prosthetic complications associated with single implant-retained mandibular overdentures (1-IODs) with locator attachments. The 1-IOD was placed in the mandibular midline by using a conventional loading protocol in 22 patients with an edentulous mandible. Marginal bone loss at the start of loading and 12 months postoperatively was assessed by radiographic and crestal bone evaluation. The crestal bone was defined as the distance between the customized abutment shoulder and the top of the bone, as indicated by probing. In addition, implant stability quotient and prosthetic complications were recorded. The cumulative implant survival rate was 95.5%. Median implant stability quotient remained greater than 80, and median radiographic bone loss was 0.56 mm. Crestal measurement showed a median crestal bone loss of 0.16, 0.43, 0.39, and 0.52 mm on the buccal, right, lingual, and left sides, respectively. Both radiographic and crestal bone loss values significantly differed between the start of implant loading and 12 months postoperatively (except on the buccal and lingual sides; P < 0.05). The need to replace the nylon insert was the most common complication. Conventional loading of a 1-IOD with a locator attachment resulted in a high survival rate, good implant stability, and acceptable marginal bone loss.

[1]  R. Emera,et al.  Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used for Mandibular Overdentures: An In Vitro Study , 2019, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[2]  M. Srinivasan,et al.  Clinical performance of LOCATOR® attachments: A retrospective study with 1–8 years of follow‐up , 2018, Clinical and experimental dental research.

[3]  M. Kanazawa,et al.  The patient general satisfaction of mandibular single-implant overdentures and conventional complete dentures , 2018, Medicine.

[4]  R. Luthardt,et al.  Survival and Complications of Single Dental Implants in the Edentulous Mandible Following Immediate or Delayed Loading: A Randomized Controlled Clinical Trial , 2017, Journal of dental research.

[5]  R. Emera,et al.  Effect of Different Degrees of Mesial Implant Inclination on the Retention and Stability of Two-Implant Mandibular Overdentures Retained with Stud Attachments: An In Vitro Study. , 2018, The International journal of oral & maxillofacial implants.

[6]  A. Alqutaibi,et al.  Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report. , 2017, International journal of oral and maxillofacial surgery.

[7]  M. A. Elsyad,et al.  Effect of Buccal Implant Inclination on Stresses Around Two-Implant-Retained Overdentures with Resilient Stud Attachments. , 2017, The International journal of oral & maxillofacial implants.

[8]  M. A. Elsyad,et al.  The effect of implant diameter on strain around implants retaining a mandibular overdenture with Locator attachments: An in vitro study. , 2016, Dental materials journal.

[9]  M. A. Elsyad,et al.  Circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures: A randomized controlled clinical trial using cone beam computed tomography. , 2016, The Journal of prosthetic dentistry.

[10]  P. Rompré,et al.  Does immediate loading affect clinical and patient-centered outcomes of mandibular 2-unsplinted-implant overdenture? A 2-year within-case analysis. , 2016, Journal of dentistry.

[11]  M. Behr,et al.  Prosthetic Complications and Maintenance Requirements in Locator-attached Implant-Supported Overdentures: A Retrospective Study. , 2016, The European journal of prosthodontics and restorative dentistry.

[12]  M. Stimmelmayr,et al.  Factors affecting peri-implant bone resorption in four Implant supported mandibular full-arch restorations: a 3-year prospective study. , 2016, Journal of clinical periodontology.

[13]  F. Vafaee,et al.  Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading , 2015, The journal of advanced prosthodontics.

[14]  J. Walton,et al.  A 5-year randomized trial to compare 1 or 2 implants for implant overdentures , 2015, BDJ.

[15]  Corina Marilena Cristache,et al.  Five-year clinical trial using three attachment systems for implant overdentures. , 2014, Clinical oral implants research.

[16]  F Müller,et al.  Implant-supported Mandibular Overdentures in Very Old Adults , 2013, Journal of dental research.

[17]  Yubo Fan,et al.  Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis. , 2013, Journal of dentistry.

[18]  Yining Wang,et al.  Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments. , 2012, Journal of dentistry.

[19]  J. Ellis,et al.  Two implant retained overdentures--a review of the literature supporting the McGill and York consensus statements. , 2012, Journal of dentistry.

[20]  W. Thomson,et al.  Mandibular two-implant overdentures: three-year prosthodontic maintenance using the locator attachment system. , 2011, The International journal of prosthodontics.

[21]  W. Thomson,et al.  Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems. , 2011, Clinical oral implants research.

[22]  B. Al-Nawas,et al.  A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. , 2009, Clinical implant dentistry and related research.

[23]  E. Piehslinger,et al.  Implant prosthodontic rehabilitation of patients with rheumatic disorders: a case series report. , 2010, The International journal of prosthodontics.

[24]  L. Hollender,et al.  A prospective randomized study on the immediate loading of mandibular overdentures supported by one or two implants: a 12-month follow-up report. , 2010, The International journal of oral & maxillofacial implants.

[25]  Lars Sennerby,et al.  Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. , 2008, Periodontology 2000.

[26]  P. Henry,et al.  A prospective study of immediately loaded single implant-retained mandibular overdentures: preliminary one-year results. , 2007, The Journal of prosthetic dentistry.

[27]  G. Zarb,et al.  The influence of early loading on bony crest height and stability: a pilot study. , 2005, The International journal of prosthodontics.

[28]  P. Petersen,et al.  Improving the oral health of older people: the approach of the WHO Global Oral Health Programme. , 2005, Community dentistry and oral epidemiology.

[29]  K. Chung,et al.  Retention characteristics of attachment systems for implant overdentures. , 2004, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[30]  Jean-Pierre Bernard,et al.  Predicting osseointegration by means of implant primary stability. , 2004, Clinical oral implants research.

[31]  T D Taylor,et al.  The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. , 2002, The International journal of oral & maxillofacial implants.

[32]  T D Taylor,et al.  The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. , 2002, Gerodontology.

[33]  C. Ulm,et al.  The symphyseal single-tooth implant for anchorage of a mandibular complete denture in geriatric patients: a clinical report. , 2001, The International journal of oral & maxillofacial implants.

[34]  Misch Ce The implant quality scale: a clinical assessment of the health--disease continuum. , 1998 .

[35]  C. Misch The implant quality scale: a clinical assessment of the health--disease continuum. , 1998, Oral health.

[36]  S. Castagna,et al.  Mandibular overdentures anchored to single implants: a five-year prospective study. , 1997, The Journal of prosthetic dentistry.

[37]  T. Albrektsson,et al.  A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant. , 1997, The International journal of oral & maxillofacial implants.

[38]  T Albrektsson,et al.  Current interpretations of the osseointegrated response: clinical significance. , 1993, The International journal of prosthodontics.