320-row CT scanning: reduction in tube current parallels reduction in radiation exposure?

Nowadays, multiple studies involving over several thousands of patients have established that CT angiography is a highly accurate noninvasive approach for delineation of the presence and severity of coronary atherosclerosis [1–35]. With its high negative predictive value cardiac CT is optimally suited for the evaluation of patients with a low or intermediate risk of coronary disease, allowing the non-invasive exclusion of coronary disease at relatively low cost and risk [36–48]. However, the appropriate radiation dose remains an important issue in cardiac CT. On one hand, a too low radiation dose may result in a high level of image noise and therefore in non-evaluable images. On the other hand, using higher radiation exposure levels may put patients at unnecessary risk of radiation damage [49–58]. Effective strategies to reduce radiation dose, such as prospective gating, ECG-correlated modulation of the tube current, and tube voltage below 100 kV, are becoming more and more available [59–65]. Leschka et al. [61] showed that adjustment of the scan length of CT coronary angiography using the images from calcium scoring instead of the scout was associated with a 16% reduction in radiation dose of dual-source CT coronary angiography. In a large multicenter study of coronary CT angiography in patients with excellent heart rate control, Labounty et al. [62] reported that the use of minimal padding (i.e. additional surrounding X-ray beam on time), was associated with a substantial reduction in radiation dose (from mean 5.7 mSv to mean 2.0 mSv) together with preserved image interpretability. Rogalla et al. [63] showed that the anterior-posterior diameter adapted tube current in dynamic volume CT coronary angiography provided a new simple and practical approach to keep image quality constant by accounting for differences in patient size. Maintaining a constant image quality in CT, independent of patient body habitus, significantly contributed to a substantially improved diagnostic image quality together with a reduced radiation dose for the patient. Blankstein et al. [64] investigated the effective radiation dose and image quality of 100 kV versus 120 kV tube voltage among patients referred for cardiac dual source CT imaging in 294 consecutive patients. They convincingly demonstrated that use of low kV resulted in a substantial reduction of radiation dose without compromising image quality. The effective radiation dose for the 100 and 120 kV scans was 8.5 and 15.4 mSv, respectively. In the recently published PROTECTION II trial, Hausleiter et al. [65] studied 400 non-obese patients undergoing CT angiography with either 100 or 120 kV CT angiography. The study specifically examined the impact of a reduction in tube voltage to 100 kV using 64-slice CT angiography systems from three different manufacturers. It was demonstrated that a further 31% reduction in radiation exposure could be obtained with 100 kV tube voltage settings while image quality was preserved. In the current issue of the International Journal of Cardiovascular Imaging, Zhang et al. [66] prospectively evaluated image quality parameters, contrast volume and radiation dose at the 100 kV tube voltage setting during CT coronary angiography. Interestingly, the authors used a 320-row CT scanner. The authors studied 107 consecutive patients with a heart rate <65 beats per minute who underwent prospective ECG-triggered CT coronary angiography. A total of 40 patients with a body mass index <25 kg/m² were scanned using 100 kV tube voltage settings, whereas 67 patients were scanned using the 120 kV protocol. Contrast-to-noise ratios and contrast material volumes were calculated. Adequate diagnostic image quality was achieved in 98.2% of coronary segments with 100 kV CT coronary angiography, and in 98.6% of coronary segments with 120 kV CT coronary angiography, without significant differences in image quality scores for each coronary segment. Vessel attenuation, image noise, and contrast-to-noise ratios were not significantly different between the 100 kV and 120 kV protocols. Mean contrast injection rate and mean material volume were significantly lower for the 100 kV tube voltage setting than for the 120 kV protocol. The effective radiation dose was 2.12 ± 0.19 mSv for 100 kV CT coronary angiography, which is a reduction of 54% compared to 4.61 ± 0.82 mSv for 120 kV CT coronary angiography. A 100 kV CT coronary angiography can be implemented in patients with a body mass index <25 kg/m². The 100 kV setting allowed significant reductions in contrast material volume and effective radiation dose while maintaining adequate diagnostic image quality. The interesting study by Zhang et al. [66] represents the first evaluation by a 320-row CT scanner of the 100 kV protocol for CT coronary angiography with respect to image quality, contrast volume, and radiation exposure. This is an appropriate and timely approach, as the use of 320-row MSTC scanners is increasing over the past years [67–71]. In principle, whole-heart 320-row CT angiography avoids exposure-intensive overscanning and overranging, offering the potential to significantly reduce radiation dose. The main results of the present study indicate that 100 kV CT coronary angiography using a 320-row scanner is feasible in patients with a body mass index of <25 kg/m, visualizing more than 98% of coronary segments with appropriate diagnostic image quality. A dose reduction of even 54% for the 100 kV tube setting was reached. The image quality was reduced by motion artifacts in nearly 21% of segments. However, this held for both the 100 kV and the 120 kV tube voltage settings. Blurring by calcification was more common for the 100 kV protocol than for the 120 kV protocol. Theoretically, the 100 kV voltage setting may increase blooming artifacts from dense structures such as calcification, which precludes accurate evaluation of the lumen of the coronary arteries. Consequently, future studies using the 100 kV protocol should focus on the influence of calcification on image quality, and the potential interference of the 100 kV protocol with edequate evaluation of both coronary arteries and coronary stenoses, especially for calcified segments and identification of soft plaques. To conclude, Zhang et al. [66] have clearly demonstrated that for patients with a body mass index of <25 kg/m², 100 kV CT coronary angiography can be validly performed using a 320-row CT scanner. This approach allows a significant reduction of 54% in contrast and radiation doses, while maintaining adequate diagnostic image quality. The study extends previous findings that the reduction in tube current may be a feasible standard addition to the other strategies for reducing potential radiation exposure in patients undergoing CT coronary angiography.

[1]  R J van der Geest,et al.  Automated measurement of volume flow in the ascending aorta using MR velocity maps: evaluation of inter- and intraobserver variability in healthy volunteers. , 1998, Journal of computer assisted tomography.

[2]  Jeroen J. Bax,et al.  Noninvasive evaluation with multislice computed tomography in suspected acute coronary syndrome: plaque morphology on multislice computed tomography versus coronary calcium score. , 2008, Journal of the American College of Cardiology.

[3]  J. Jukema,et al.  Lesional Overexpression of Matrix Metalloproteinase-9 Promotes Intraplaque Hemorrhage in Advanced Lesions But Not at Earlier Stages of Atherogenesis , 2005, Arteriosclerosis, thrombosis, and vascular biology.

[4]  E. E. van der Wall,et al.  Comparison of ultrafast dipyridamole magnetic resonance imaging with dipyridamole sestamibi SPECT for detection of perfusion abnormalities in patients with one‐vessel coronary artery disease: Assessment by quantitative model fitting , 1996, Magnetic resonance in medicine.

[5]  P. Serruys,et al.  Relation between infarct size and left ventricular performance assessed in patients with first acute myocardial infarction randomized to intracoronary thrombolytic therapy or to conventional treatment. , 1988, The American journal of cardiology.

[6]  J. Schuijf,et al.  Anatomical and functional imaging techniques: basically similar or fundamentally different? , 2007, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[7]  R. Morin,et al.  Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography , 2005, The International Journal of Cardiovascular Imaging.

[8]  Jeroen J. Bax,et al.  Myocardial contractile reserve predicts improvement in left ventricular function after cardiac resynchronization therapy. , 2007, American heart journal.

[9]  H. Alkadhi,et al.  Scan length adjustment of CT coronary angiography using the calcium scoring scan: effect on radiation dose. , 2010, AJR. American journal of roentgenology.

[10]  W. Morshuis,et al.  Giant aneurysm of an aortocoronary venous bypass graft compressing the right ventricle , 2007, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[11]  E. E. van der Wall,et al.  Effects of a new calcium antagonist, mibefradil (Ro 40-5967), on silent ischemia in patients with stable chronic angina pectoris: a multicenter placebo-controlled study. The Mibefradil International Study Group. , 1996, Journal of the American College of Cardiology.

[12]  E. E. van der Wall,et al.  Risks of oral anticoagulant therapy with increasing age. , 2005, Archives of internal medicine.

[13]  Jeroen J. Bax,et al.  Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography. , 2002, The American journal of cardiology.

[14]  A de Roos,et al.  Cardiac first-pass and myocardial perfusion in normal subjects assessed by sub-second Gd-DTPA enhanced MR imaging. , 1991, Journal of computer assisted tomography.

[15]  Jeroen J. Bax,et al.  Non-invasive visualization of the coronary arteries with multi-detector row computed tomograpy; influence of technical advances on clinical applicability , 2005, The International Journal of Cardiovascular Imaging.

[16]  H. Suryapranata,et al.  Left main coronary artery stenosis undetected by 64-slice computed tomography: a word of caution , 2007, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[17]  M. Meijerink,et al.  Towards a noninvasive anatomical and functional diagnostic work-up of patients with suspected coronary artery disease , 2010, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[18]  Jeroen J. Bax,et al.  Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography. , 2006, Journal of the American College of Cardiology.

[19]  E. Wall,et al.  Pseudo-aortic dissection after primary PCI , 2007, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[20]  Jeroen J. Bax,et al.  Impact of viability and scar tissue on response to cardiac resynchronization therapy in ischaemic heart failure patients. , 2006, European heart journal.

[21]  F. Tatsugami,et al.  Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography. , 2010, Academic radiology.

[22]  Jeroen J. Bax,et al.  Cardiac resynchronization therapy in patients with a narrow QRS complex. , 2006, Journal of the American College of Cardiology.

[23]  P. V. van Dijkman,et al.  Acute, subacute, and chronic myocardial infarction: quantitative analysis of gadolinium-enhanced MR images. , 1991, Radiology.

[24]  Jeroen J. Bax,et al.  Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent Restenosis , 2010, Investigative radiology.

[25]  Jeroen J. Bax,et al.  Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease. , 2006, The American journal of cardiology.

[26]  Jeroen J. Bax,et al.  Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease. , 2010, European heart journal.

[27]  E. E. van der Wall,et al.  Lack of Negative Inotropic Effects of the New Calcium Antagonist Ro 40–5967 in Patients with Stable Angina Pectoris , 1991, Journal of cardiovascular pharmacology.

[28]  Bernhard Bischoff,et al.  Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial. , 2010, JACC. Cardiovascular imaging.

[29]  Jeroen J. Bax,et al.  Prevalence of coronary artery disease and plaque morphology assessed by multi-slice computed tomography coronary angiography and calcium scoring in asymptomatic patients with type 2 diabetes , 2007, Heart.

[30]  E. E. van der Wall,et al.  Gated single-photon emission computed tomographic myocardial imaging: a new tool in clinical cardiology. , 2001, American heart journal.

[31]  E. E. van der Wall CT angiography, underuse, overuse, or appropriate use? , 2009, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[32]  Jeroen J. Bax,et al.  Effect of total scar burden on contrast-enhanced magnetic resonance imaging on response to cardiac resynchronization therapy. , 2007, The American journal of cardiology.

[33]  Jeroen J. Bax,et al.  Comparison of response to cardiac resynchronization therapy in patients with sinus rhythm versus chronic atrial fibrillation. , 2004, The American journal of cardiology.

[34]  Jörg Hausleiter,et al.  Estimated radiation dose associated with cardiac CT angiography. , 2009, JAMA.

[35]  R. Geuns,et al.  Dobutamine stress MRI versus threedimensional contrast echocardiography: It’s all Black and White , 2008, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[36]  Mark Lubberink,et al.  Cardiac PET-CT: advanced hybrid imaging for the detection of coronary artery disease , 2010, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[37]  Udo Hoffmann,et al.  Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image quality , 2011, The International Journal of Cardiovascular Imaging.

[38]  Marcel J. W. Greuter,et al.  Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study , 2007, The International Journal of Cardiovascular Imaging.

[39]  A. Roos,et al.  Myocardial infarct sizing and assessment of reperfusion by magnetic resonance imaging: a review , 1991, The International Journal of Cardiac Imaging.

[40]  G. Heidendal,et al.  I-123 labeled hexadecenoic acid in comparison with Thallium-201 for myocardial imaging in coronary heart disease , 1980, European Journal of Nuclear Medicine.

[41]  J. Leipsic,et al.  Effect of padding duration on radiation dose and image interpretation in prospectively ECG-triggered coronary CT angiography. , 2010, AJR. American journal of roentgenology.

[42]  G. Heidendal,et al.  Dynamic myocardial scintigraphy with 123I-labeled free fatty acids in patients with myocardial infarction , 2004, European Journal of Nuclear Medicine.

[43]  A. Zwinderman,et al.  Functional and metabolic evaluation of the athlete's heart by magnetic resonance imaging and dobutamine stress magnetic resonance spectroscopy. , 1998, Circulation.

[44]  Jeroen J. Bax,et al.  Relative merits of M-mode echocardiography and tissue Doppler imaging for prediction of response to cardiac resynchronization therapy in patients with heart failure secondary to ischemic or idiopathic dilated cardiomyopathy. , 2007, The American journal of cardiology.

[45]  B. Hamm,et al.  Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy: Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation , 2009, Circulation.

[46]  Jeroen J. Bax,et al.  Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease. , 2007, Journal of the American College of Cardiology.

[47]  Jeroen J. Bax,et al.  Multi‐slice computed tomography in the evaluation of patients with acute chest pain , 2007, Acute cardiac care.

[48]  Katja Zeppenfeld,et al.  Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures. , 2005, Heart rhythm.

[49]  H. Kashani,et al.  Radiation dose optimisation in dynamic volume CT of the heart: tube current adaptation based on anterior–posterior chest diameter , 2010, The International Journal of Cardiovascular Imaging.

[50]  Jeroen J. Bax,et al.  Different manifestations of coronary artery disease by stress SPECT myocardial perfusion imaging, coronary calcium scoring, and multislice CT coronary angiography in asymptomatic patients with type 2 diabetes mellitus , 2008, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[51]  Jeroen J. Bax,et al.  Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation. , 2006, Journal of the American College of Cardiology.

[52]  Jeroen J. Bax,et al.  Clinical versus echocardiographic parameters to assess response to cardiac resynchronization therapy. , 2006, The American journal of cardiology.

[53]  P. V. van Dijkman,et al.  Myocardial infarct size after reperfusion therapy: assessment with Gd-DTPA-enhanced MR imaging. , 1990, Radiology.

[54]  E. E. van der Wall,et al.  Effects of the new calcium antagonist mibefradil (Ro 40-5967) on exercise duration in patients with chronic stable angina pectoris: a multicenter, placebo-controlled study. Ro 40-5967 International Study Group. , 1995, American heart journal.

[55]  E. E. van der Wall,et al.  Risk factors for coronary heart disease: implications of gender. , 2002, Cardiovascular research.

[56]  E. Wall,et al.  Imaging in cardiac resynchronisation therapy , 2008, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[57]  Gary S. Mintz,et al.  Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses: Final Results of a Randomized Comparison With Angiographic Guidance (TULIP Study) , 2003, Circulation.

[58]  R. J. van der Geest,et al.  Noninvasive evaluation of aortocoronary bypass grafts with magnetic resonance flow mapping. , 1995, The American journal of cardiology.

[59]  P. V. van Dijkman,et al.  Diagnostic significance of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in thrombolytic treatment for acute myocardial infarction: its potential in assessing reperfusion. , 1990, British heart journal.

[60]  P. D. de Feyter,et al.  Combining noninvasive anatomical imaging with invasive functional information: an unconventional but appropriate hybrid approach , 2009, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[61]  Jeroen J. Bax,et al.  Anatomic correlates of a normal perfusion scan using 64-slice computed tomographic coronary angiography. , 2011, The American journal of cardiology.

[62]  Zhao-qi Zhang,et al.  320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose , 2011, The International Journal of Cardiovascular Imaging.

[63]  Hubert W. Vliegen,et al.  Magnetic Resonance Imaging in Coronary Artery Disease , 1991, Developments in Cardiovascular Medicine.

[64]  G. Ertas,et al.  Late stent thrombosis, endothelialisation and drug-eluting stents , 2009, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[65]  M. Oudkerk,et al.  Discordance between anatomical and functional coronary stenosis severity. , 2007, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[66]  J. Jukema,et al.  Value of fast gradient echo magnetic resonance angiography as an adjunct to coronary arteriography in detecting and confirming the course of clinically significant coronary artery anomalies. , 1997, The American journal of cardiology.

[67]  A de Roos,et al.  Usefulness of ultrafast magnetic resonance imaging in healed myocardial infarction. , 1992, The American journal of cardiology.

[68]  G. Lu,et al.  Incidence of anomalous origin of coronary artery in 1879 Chinese adults on dual-source CT angiography , 2010, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[69]  A. Weustink,et al.  Coronary artery anomalies detected by MSCT-coronary angiography in the adult , 2008, Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation.

[70]  P. V. van Dijkman,et al.  Comparison of magnetic resonance imaging studies with enzymatic indexes of myocardial necrosis for quantification of myocardial infarct size. , 1993, The American journal of cardiology.