Hydraulic Characterization of Implantable Rotary Blood Pumps

Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine their interaction with the cardiovascular system. A systematic comparison in this regard has not yet been performed for different clinically used RBPs. The aim of this study is to describe the hydraulic characteristics of four RBPs with a universal mathematical model and to compare their behavior under clinical operating conditions. Methods: First, static and dynamic pump properties of four RBPs (HVAD, Heartmate II, Heartmate 3, and Incor) including their peripheral components were identified in an in vitro setup; results were translated into mathematical models based on principles of turbomachinery including the low and backflow regions. Second, the four hydraulic models were compared in a numerical simulation of the cardiovascular system for full- and partial-support conditions. Results: A model structure applicable to each of the investigated RBPs was developed. Deviations between simulated and measured signals for static and dynamic properties were small (2.6 ± 0.5 mmHg, 0.38 ± 0.14 L/min, respectively). For a simulated partial support condition, flow pulsatility ranged from 4.1 (Incor) to 9.1 L/min (HVAD). Negative flow rates during diastole were observed in three out of four pumps. Conclusion: Hydraulic properties differ greatly between the investigated RBPs, with flat characteristics for the HVAD and Heartmate II and steeper curves for the Heartmate 3 and especially the Incor. Significance: Hydraulic characteristics of implantable RBPs are particularly important at lower pump flow rates if backflow is to be avoided. For further research, we provide dynamic hydraulic models of the four RBPs including their periphery.

[1]  D. Burkhoff,et al.  Hemodynamics of Mechanical Circulatory Support. , 2015, Journal of the American College of Cardiology.

[2]  Robert L Kormos,et al.  Eighth annual INTERMACS report: Special focus on framing the impact of adverse events. , 2017, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[3]  S. Russell,et al.  Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  K. Muthiah,et al.  Normalisation of haemodynamics in patients with end-stage heart failure with continuous-flow left ventricular assist device therapy. , 2014, Heart, lung & circulation.

[5]  Jeffrey C. Lagarias,et al.  Convergence Properties of the Nelder-Mead Simplex Method in Low Dimensions , 1998, SIAM J. Optim..

[6]  W. Cohn,et al.  In vivo evaluation of the HeartWare centrifugal ventricular assist device. , 2007, Texas Heart Institute journal.

[7]  F. Casas,et al.  Development of a pump flow estimator for rotary blood pumps to enhance monitoring of ventricular function. , 2012, Artificial organs.

[8]  Lino Guzzella,et al.  A Novel Interface for Hybrid Mock Circulations to Evaluate Ventricular Assist Devices , 2013, IEEE Transactions on Biomedical Engineering.

[9]  Mikhail Skliar,et al.  Modeling and Control of a Brushless DC Axial Flow Ventricular Assist Device , 2002, ASAIO journal.

[10]  M. Stone Cross‐Validatory Choice and Assessment of Statistical Predictions , 1976 .

[11]  Marcel C M Rutten,et al.  Pump Flow Estimation From Pressure Head and Power Uptake for the HeartAssist5, HeartMate II, and HeartWare VADs , 2013, ASAIO journal.

[12]  M. Meboldt,et al.  Control of the Fluid Viscosity in a Mock Circulation , 2018, Artificial organs.

[13]  D. Zimpfer,et al.  Assessment of aortic valve opening during rotary blood pump support using pump signals. , 2014, Artificial organs.

[14]  Guido Danieli,et al.  A Modified Elastance Model to Control Mock Ventricles in Real-Time: Numerical and Experimental Validation , 2008, ASAIO journal.

[15]  Heinrich Schima,et al.  Dynamic Modeling and Identification of an Axial Flow Ventricular Assist Device , 2009, The International journal of artificial organs.

[16]  Daniel Tamez,et al.  Design concepts and principle of operation of the HeartWare ventricular assist system. , 2010, ASAIO journal.

[17]  J. R. Boston,et al.  Modeling and identification of an axial flow blood pump , 1997, Proceedings of the 1997 American Control Conference (Cat. No.97CH36041).

[18]  Guy A. MacGowan,et al.  Effect of Left Ventricular Assist Device Implantation and Heart Transplantation on Habitual Physical Activity and Quality of Life☆ , 2014, The American journal of cardiology.

[19]  Maciej Kozarski,et al.  Continuous-flow pump model study: the effect on pump performance of pump characteristics and cardiovascular conditions , 2013, Journal of Artificial Organs.

[20]  Mirko Meboldt,et al.  Left Ventricular Assist Devices: Challenges Toward Sustaining Long-Term Patient Care , 2017, Annals of Biomedical Engineering.

[21]  N. Smedira,et al.  Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice. , 2013, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[22]  John Gorcsan,et al.  The NHLBI REVIVE-IT study: Understanding its discontinuation in the context of current left ventricular assist device therapy. , 2016, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[23]  Valluvan Jeevanandam,et al.  Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure , 2017, The New England journal of medicine.

[24]  D. Zimpfer,et al.  Minimally invasive thoratec Heartmate II implantation in the setting of severe thoracic aortic calcification. , 2013, The Annals of thoracic surgery.

[25]  Fang Yang,et al.  High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions. , 2015, The Journal of thoracic and cardiovascular surgery.

[26]  Volkmar Falk,et al.  2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure. , 2016, Revista espanola de cardiologia.

[27]  D. Owens,et al.  Cost-Effectiveness of Left Ventricular Assist Devices in Ambulatory Patients With Advanced Heart Failure. , 2017, JACC. Heart failure.

[28]  M Komeda,et al.  Physical model-based indirect measurements of blood pressure and flow using a centrifugal pump. , 2000, Artificial organs.

[29]  P. Lawford,et al.  Numerical Modeling of Hemodynamics with Pulsatile Impeller Pump Support , 2010, Annals of Biomedical Engineering.

[30]  J D Thomas,et al.  Numeric modeling of the cardiovascular system with a left ventricular assist device. , 1999, ASAIO journal.

[31]  H. Nishida,et al.  Clinical application of a newly developed autoflow control system for the Terumo centrifugal pump: from external control to built-in direct control. , 1996, Artificial organs.

[32]  D. Burkhoff,et al.  Partial mechanical long-term support with the CircuLite Synergy pump as bridge-to-transplant in congestive heart failure. , 2010, The Thoracic and cardiovascular surgeon.

[33]  Hemodynamic analysis of outflow grafting positions of a ventricular assist device using closed-loop multiscale CFD simulations: Preliminary results. , 2016, Journal of biomechanics.

[34]  C. Selzman,et al.  In vitro pulsatility analysis of axial-flow and centrifugal-flow left ventricular assist devices. , 2013, Journal of biomechanical engineering.

[35]  Ravi Laohasurayodhin,et al.  Continuous Monitoring of Aortic Valve Opening in Rotary Blood Pump Patients , 2016, IEEE Transactions on Biomedical Engineering.

[36]  Kim H. Parker,et al.  Investigation of the Characteristics of HeartWare HVAD and Thoratec HeartMate II Under Steady and Pulsatile Flow Conditions. , 2016, Artificial organs.