Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation.
暂无分享,去创建一个
N. Uriel | D. Mancini | S. Susen | B. Jude | Y. Naka | A. Vincentelli | U. Jorde | P. Ennezat | Sang-Woo Pak | Sarah Cappleman
[1] S. Russell,et al. Advanced heart failure treated with continuous-flow left ventricular assist device. , 2009, The New England journal of medicine.
[2] M. Russo,et al. Posttransplant survival is not diminished in heart transplant recipients bridged with implantable left ventricular assist devices. , 2009, The Journal of thoracic and cardiovascular surgery.
[3] G. Felker,et al. Impact of left ventricular assist device bridging on posttransplant outcomes. , 2009, The Annals of thoracic surgery.
[4] S. Russell,et al. Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation. , 2009, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.
[5] Nader Moazami,et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. , 2009, Journal of the American College of Cardiology.
[6] L. Nielsen,et al. Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II). , 2009, Journal of the American College of Cardiology.
[7] C. O'connor,et al. Randomized Trial of Warfarin, Aspirin, and Clopidogrel in Patients With Chronic Heart Failure: The Warfarin and Antiplatelet Therapy in Chronic Heart Failure (WATCH) Trial , 2009, Circulation.
[8] R. Patten,et al. The effect of ventricular assist devices on post-transplant mortality an analysis of the United network for organ sharing thoracic registry. , 2009, Journal of the American College of Cardiology.
[9] Christoph Benk,et al. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.
[10] O H Frazier,et al. Use of a continuous-flow device in patients awaiting heart transplantation. , 2007, The New England journal of medicine.
[11] Klaus Affeld,et al. The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps. , 2007, Artificial organs.
[12] P. Toutouzas,et al. Efficacy of antithrombotic therapy in chronic heart failure: The HELAS study , 2006, European journal of heart failure.
[13] G. Lip,et al. Effects of congestive heart failure on plasma von Willebrand factor and soluble P-selectin concentrations in patients with non-valvar atrial fibrillation , 2005, Heart.
[14] M. Kuduvalli,et al. Effect of peri-operative red blood cell transfusion on 30-day and 1-year mortality following coronary artery bypass surgery. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.
[15] C. Silliman,et al. Transfusion-related acute lung injury. , 2005, Blood.
[16] P A Poole-Wilson,et al. The Warfarin/Aspirin Study in Heart failure (WASH): a randomized trial comparing antithrombotic strategies for patients with heart failure. , 2004, American heart journal.
[17] S. Susen,et al. Acquired von Willebrand syndrome in aortic stenosis. , 2003, The New England journal of medicine.
[18] P. V. van Genderen,et al. Acquired von Willebrand Syndrome: Data from an International Registry , 2000, Thrombosis and Haemostasis.
[19] D. Gozal,et al. Pulmonary risk factors compromising postoperative recovery after surgical repair for congenital heart disease. , 1999, Chest.
[20] R. Marchant,et al. Shear-dependent changes in the three-dimensional structure of human von Willebrand factor. , 1996, Blood.
[21] A. Street,et al. Reversal of aortic stenosis, bleeding gastrointestinal angiodysplasia, and von Willebrand syndrome by aortic valve replacement , 1996, The Lancet.
[22] J. Townend,et al. Coronary angioplasty plus stent in LAD disease , 1996, The Lancet.
[23] R. Nagel,et al. Shear stress enhances the proteolysis of von Willebrand factor in normal plasma. , 1994, Blood.
[24] D. Morgan,et al. Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand's disease the link? , 1992, The Lancet.
[25] Andrew Boyle,et al. Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. , 2009, The Journal of thoracic and cardiovascular surgery.
[26] B. Lytle,et al. Transfusion increases the risk of postoperative infection after cardiovascular surgery. , 2006, Journal of the American College of Surgeons.
[27] T. Myers,et al. Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.
[28] Kyung W. Park,et al. Transfusion-Associated Complications , 2004, International anesthesiology clinics.
[29] E. C. Heyde. Gastrointestinal bleeding in aortic stenosis. , 1958 .