Three-phase AC/DC converter with high power factor

The paper presents a three-phase AC/DC converter to achieve power-factor correction, harmonics elimination, DC-bus-voltage regulation and neutral-point-voltage compensation. The proposed converter can achieve bidirectional power-flow capability. Therefore the converter can be applied for active power-filter operation. Two legs are adopted in the proposed converter to achieve three-level pulse-width modulation (PWM) and control the line currents to be sinusoidal waves in phase with supply voltages. Three control loops, DC-link-voltage control, neutral-point-voltage compensation and line current control, were used in the control scheme to achieve DC-bus-voltage regulation, to balance neutral-point voltage and to draw the sinusoidal line currents. The mathematical model of the converter was derived and the control scheme is provided. The effectiveness of the proposed control scheme is verified through computer simulation and experiments.

[1]  S. Hui,et al.  Characterization of single-stage three-phase power-factor-correction circuit using modular single-phase PWM DC-to-DC converters , 2000 .

[2]  B.-R. Lin,et al.  Analysis and implementation of a three-phase two-leg neutral point clamped converter based on space vector PWM for power factor correction , 2004 .

[3]  D. Boroyevich,et al.  New high power, high performance power converter systems , 1998 .

[4]  Thomas A. Lipo,et al.  Dual AC-drive system with a reduced switch count , 2001 .

[5]  D. Boroyevich,et al.  Limits of the neutral-point balance in back-to-back-connected three-level converters , 2004, IEEE Transactions on Power Electronics.

[6]  Chongming Qiao,et al.  Three-phase unity-power-factor star-connected switch (VIENNA) rectifier with unified constant-frequency integration control , 2003 .

[7]  Marian P. Kazmierkowski,et al.  Simple direct power control of three-phase PWM rectifier using space-vector modulation (DPC-SVM) , 2004, IEEE Transactions on Industrial Electronics.

[8]  A. J. Visser,et al.  Transformerless series sag compensation with a cascaded multilevel inverter , 2002, IEEE Trans. Ind. Electron..

[9]  Wang Xiao-yan,et al.  Difference of GB 1 7625.1-2003 《Electromagnetic Compatibility-Limits-Limits for Harmonic Current Emissions (Equipment Input Current Per Phase≤16A)》 , 2003 .

[10]  Fang Zheng Peng,et al.  Multilevel inverters: a survey of topologies, controls, and applications , 2002, IEEE Trans. Ind. Electron..

[11]  Thierry Meynard,et al.  A simulation-optimization system for the optimal design of a multilevel inverter , 1999 .

[12]  A. V. Stankovic Input-output harmonic elimination of the PWM Boost Type Rectifier under unbalanced operating conditions , 1998 .