Spillover and Partial-Volume Correction for Image-Derived Input Functions for Small-Animal 18F-FDG PET Studies

We present and validate a method to obtain an input function from dynamic image data and 0 or 1 blood sample for small-animal 18F-FDG PET studies. The method accounts for spillover and partial-volume effects via a physiologic model to yield a model-corrected input function (MCIF). Methods: Image-derived input functions (IDIFs) from heart ventricles and myocardial time–activity curves were obtained from 14 Sprague–Dawley rats and 17 C57BL/6 mice. Each MCIF was expressed as a mathematic equation with 7 parameters, which were estimated simultaneously with the myocardial model parameters by fitting the IDIFs and myocardium curves to a dual-output compartment model. Zero or 1 late blood sample was used in the simultaneous estimation. MCIF was validated by comparison with input measured from blood samples. Validation included computing errors in the areas under the curves (AUCs) and in the 18F-FDG influx constant Ki in 3 types of tissue. Results: For the rat data, the AUC error was 5.3% ± 19.0% in the 0-sample MCIF and −2.3% ± 14.8% in the 1-sample MCIF. When the MCIF was used to calculate the Ki of the myocardium, brain, and muscle, the overall errors were −6.3% ± 27.0% in the 0-sample method (correlation coefficient r = 0.967) and 3.1% ± 20.6% in the 1-sample method (r = 0.970). The t test failed to detect a significant difference (P > 0.05) in the Ki estimates from both the 0-sample and the 1-sample MCIF. For the mouse data, AUC errors were 4.3% ± 25.5% in the 0-sample MCIF and −1.7% ± 20.9% in the 1-sample MCIF. Ki errors averaged −8.0% ± 27.6% for the 0-sample method (r = 0.955) and −2.8% ± 22.7% for the 1-sample method (r = 0.971). The t test detected significant differences in the brain and muscle in the Ki for the 0-sample method but no significant differences with the 1-sample method. In both rat and mouse, 0-sample and 1-sample MCIFs both showed at least a 10-fold reduction in AUC and Ki errors compared with uncorrected IDIFs. Conclusion: MCIF provides a reliable, noninvasive estimate of the input function that can be used to accurately quantify the glucose metabolic rate in small-animal 18F-FDG PET studies.

[1]  D. Feng,et al.  Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography. , 1993, International journal of bio-medical computing.

[2]  Sung-Cheng Huang,et al.  In Vivo Quantitation of Glucose Metabolism in Mice Using Small-Animal PET and a Microfluidic Device , 2007, Journal of Nuclear Medicine.

[3]  A A Lammertsma,et al.  Image-derived input functions for determination of MRGlu in cardiac (18)F-FDG PET scans. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Philipp T. Meyer,et al.  Simplified quantification of small animal [18F]FDG PET studies using a standard arterial input function , 2006, European Journal of Nuclear Medicine and Molecular Imaging.

[5]  Roger Lecomte,et al.  A New Tool for Molecular Imaging: The Microvolumetric β Blood Counter , 2007, Journal of Nuclear Medicine.

[6]  A new tool for molecular imaging: the microvolumetric beta blood counter. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  Raymond F Muzic,et al.  Evaluation of objective functions for estimation of kinetic parameters. , 2006, Medical physics.

[8]  E. Hoffman,et al.  Noninvasive determination of local cerebral metabolic rate of glucose in man. , 1980, The American journal of physiology.

[9]  H. Schelbert,et al.  Left ventricular blood TAC quantitation with microPET imaging in mice using MAP, FBP and blood sampling , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[10]  H.M. Wu,et al.  A Public Domain Dynamic Mouse FDG MicroPET Image Data Set for Evaluation and Validation of Input Function Derivation Methods , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[11]  D. Feng,et al.  Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input Function , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  E. Hoffman,et al.  TOMOGRAPHIC MEASUREMENT OF LOCAL CEREBRAL GLUCOSE METABOLIC RATE IN HUMANS WITH (F‐18)2‐FLUORO-2‐DEOXY-D‐GLUCOSE: VALIDATION OF METHOD , 1980, Annals of neurology.

[13]  P. Fox,et al.  Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labelled water: the application of a cardiac time–activity curve for the tracer arterial input function , 2005, Nuclear medicine communications.

[14]  David Dagan Feng,et al.  Simultaneous estimation of physiological parameters and the input function - in vivo PET data , 2001, IEEE Transactions on Information Technology in Biomedicine.

[15]  R F Muzic,et al.  COMKAT: compartment model kinetic analysis tool. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Thomas F. Coleman,et al.  An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds , 1993, SIAM J. Optim..

[17]  S. Cherry,et al.  Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating , 2005, Physics in medicine and biology.

[18]  T. Momose,et al.  Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  P K Banerjee,et al.  Noninvasive methods for quantitating blood time-activity curves from mouse PET images obtained with fluorine-18-fluorodeoxyglucose. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  Yuan-Chuan Tai,et al.  Minimally invasive method of determining blood input function from PET images in rodents. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  Cyrill Burger,et al.  A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals , 2002, European Journal of Nuclear Medicine and Molecular Imaging.