Operation and Test Results From the SULTAN Test Facility

In the period between August 2010 and August 2011 the SULTAN test facility has been continuously operated, with over one dozen test campaigns. Among the ITER conductors, five Toroidal Field (TF) samples, two Central Solenoid (CS) samples and four NbTi samples for Poloidal Field (PF), Correction Coil and Main Busbar coming from Japan, Russia, Korea and China have been tested with duration of test campaign ranging from two to nine weeks each. Two non-ITER conductor samples are also tested in the same period, a high current NbTi cable-in-conduit (CICC) for the secondary winding of the EDIPO flux pump and a prototype high field conductor for the hybrid magnet of the Radboud University (NL). The possibility to apply “off-SULTAN” thermal cycles from room temperature to liquid nitrogen has been realized for two samples. A novel method for in-situ measurement of the critical temperature in CICC has been successfully applied in SULTAN, opening the possibility to experimentally assess the thermal strain of the filaments at various stages of the test campaign, i.e. as a function of the load cycles and degradation. Residual strain measurements on the steel jacket of the TF conductors have been carried out at RT and 77 K.

[1]  Rainer Wesche,et al.  The voltage/current characteristic (n index) of the cable-in-conduit conductors for fusion , 2003 .

[2]  Laura Savoldi,et al.  Pressure drop analysis in the CS insert coil , 2002 .

[4]  B. Stepanov,et al.  In Situ $T_{c}$ Measurements of Cable in Conduit Conductors via an Inductive Method , 2012, IEEE Transactions on Applied Superconductivity.

[5]  Rainer Wesche,et al.  Status Report of the SULTAN Test Facility , 2010, IEEE Transactions on Applied Superconductivity.

[6]  Rainer Wesche,et al.  Results of Thermal Strain and Conductor Elongation Upon Heat Treatment for ${\rm Nb}_{3}{\rm Sn}$ Cable-in-Conduit Conductors , 2010, IEEE Transactions on Applied Superconductivity.

[7]  B. Stepanov,et al.  Effect of Thermal Loading on ${\rm Nb}_{3}{\rm Sn}$ CICC Performance , 2012, IEEE Transactions on Applied Superconductivity.

[8]  T. Hemmi,et al.  Test Results and Investigation of Tcs Degradation in Japanese ITER CS Conductor Samples , 2012, IEEE Transactions on Applied Superconductivity.

[9]  Yuehua Wu,et al.  The results of the second Chinese TF conductor sample , 2011 .

[10]  S. P. Kwon,et al.  Conductor Performance Qualification of TFKO3 Sample for ITER TF Magnet , 2012, IEEE Transactions on Applied Superconductivity.

[11]  P. Bruzzone,et al.  DC performance, AC loss and transient field stability of five medium size NbTi cable-in-conduit conductors with parametric variations , 2005 .

[12]  Rainer Wesche,et al.  Test of ITER conductors in SULTAN: An update , 2011 .

[13]  R. Zanino,et al.  Test Results of Two European ITER TF Conductor Samples in SULTAN , 2008, IEEE Transactions on Applied Superconductivity.