A new normal mode dv/dt filter with resistor failure detection circuit

Insulated Gate Bipolar Transistors (IGBTs) will soon be replaced by wide band gap devices (SiC and GaN) as the choice for power semi-conductor switch in Voltage Source Inverters. These devices have extremely fast rise time and fall time compared to IGBT devices. The high dv/dt of PWM outputs create excessive voltage stress in the insulation system of AC motors due to voltage reflection issues associated with motors at large distances from the drive. In many oil field applications, the distance between the motor and the Variable Frequency Drive (VFD) approaches 300m. In walking rig applications, it is common to use multiple smaller sized conductors per phase, bunched together, to achieve the desired ampacity. This practice results in higher than usual value of the cable parasitic capacitance. Traditional dv/dt filters used for mitigating over-voltage at motor terminals, have been found to be inadequate in reducing the over voltage at the motor terminals in such oil field installations. The damping resistor often experiences high voltage and gets damaged. A new dv/dt filter suitable for use with high power AC motors at distances nearing 300m with a built-in resistor failure detection circuit is proposed here. Test results are given to demonstrate its efficacy.

[1]  C. J. Melhorn,et al.  Transient effects of PWM drives on induction motors , 1995, Proceedings of 1995 Industrial and Commercial Power Systems Conference.

[2]  David Leggate,et al.  Interaction of drive modulation and cable parameters on AC motor transients , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[3]  William D. Stevenson,et al.  Elements of Power System Analysis , 1962 .