Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis.

PURPOSE To evaluate the effectiveness of spectral CT in reducing metal artifacts caused by pedicle screws in patients with scoliosis. MATERIALS AND METHODS Institutional review committee approval and written informed consents from patients were obtained. 18 scoliotic patients with a total of 228 pedicle screws who underwent spectral CT imaging were included in this study. Monochromatic image sets with and without the additional metal artifacts reduction software (MARS) correction were generated with photon energy at 65keV and from 70 to 140keV with 10keV interval using the 80kVp and 140kVp projection sets. Polychromatic images corresponded to the conventional 140kVp imaging were also generated from the same scan data as a control group. Both objective evaluation (screw width and quantitative artifacts index measurements) and subjective evaluation (depiction of pedicle screws, surrounding structures and their relationship) were performed. RESULTS Image quality of monochromatic images in the range from 110 to 140keV (0.97±0.28) was rated superior to the conventional polychromatic images (2.53±0.54) and also better than monochromatic images with lower energy. Images of energy above 100keV also give accurate measurement of the width of screws and relatively low artifacts index. The form of screws was slightly distorted in MARS reconstruction. CONCLUSIONS Compared to conventional polychromatic images, monochromatic images acquired from dual-energy CT provided superior image quality with much reduced metal artifacts of pedicle screws in patients with scoliosis. Optimal energy range was found between 110 and 140keV.

[1]  C. Corona,et al.  Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. , 2010, Journal of neurosurgery. Spine.

[2]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[3]  Manabu Ito,et al.  Accuracy Analysis of Pedicle Screw Placement in Posterior Scoliosis Surgery: Comparison Between Conventional Fluoroscopic and Computer-Assisted Technique , 2007, Spine.

[4]  D. Bradford,et al.  Complications of the Variable Screw Plate Pedicle Screw Fixation , 1991, Spine.

[5]  D. Lim,et al.  Pedicle screw instrumentation in adolescent idiopathic scoliosis (AIS) , 2011, European Spine Journal.

[6]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[7]  K Freeman,et al.  CT scans through metal scanning technique versus hardware composition. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[8]  Manabu Ito,et al.  Complications of Pedicle Screw Fixation in Reconstructive Surgery of the Cervical Spine , 2000, Spine.

[9]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[10]  David Faul,et al.  Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completion , 2009, IEEE Transactions on Medical Imaging.

[11]  C. Krestan,et al.  MDCT versus digital radiography in the evaluation of bone healing in orthopedic patients. , 2006, AJR. American journal of roentgenology.

[12]  A. Faraj,et al.  Early complications of spinal pedicle screw , 2005, European Spine Journal.

[13]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[14]  W A Kalender,et al.  Metal Artifact Reduction for Clipping and Coiling in Interventional C-Arm CT , 2010, American Journal of Neuroradiology.

[15]  Sachio Kuribayashi,et al.  Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. , 2011, Radiology.

[16]  B. Tosun,et al.  Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis , 2009, European Spine Journal.

[17]  X. Weng,et al.  [Complications associated with the technique of pedicle screw fixation]. , 2002, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae.

[18]  Jin-Suck Suh,et al.  Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software , 2012, European Radiology.

[19]  D. Fleischmann,et al.  Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. , 2011, Radiology.

[20]  Jian Ying Li,et al.  High-Definition CT Gemstone Spectral Imaging of the Brain: Initial Results of Selecting Optimal Monochromatic Image for Beam-Hardening Artifacts and Image Noise Reduction , 2011, Journal of computer assisted tomography.

[21]  Fabian Bamberg,et al.  Metal Artifact Reduction by Dual-Energy Computed Tomography Using Energetic Extrapolation: A Systematically Optimized Protocol , 2012, Investigative radiology.

[22]  Joel G Fletcher,et al.  Metal Artifact Reduction From Reformatted Projections for Hip Prostheses in Multislice Helical Computed Tomography: Techniques and Initial Clinical Results , 2009, Investigative radiology.

[23]  Alexander Brook,et al.  Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers. , 2012, Radiology.

[24]  Yiannis Kyriakou,et al.  Reducing Metal Artifacts in Computed Tomography Caused by Hip Endoprostheses Using a Physics-Based Approach , 2010, Investigative radiology.

[25]  H. Hashidate,et al.  Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis , 2010, Spine.