Adaptive Balancing by Reactive Compensators of Three-Phase Linear Loads Supplied by Nonsinusoidal Voltage from Four-Wire Lines

A method of the design of an adaptive balancing reactive compensator in four-wire systems with linear loads and nonsinusoidal voltage is described in this article. The method of compensation is founded on the Currents’ Physical Components (CPC) – based power theory of three-phase systems with nonsinusoidal voltages and currents. The compensator is built of two sub-compensators of Y and  structure, respectively. The Y compensator reduces the reactive current and the zero sequence symmetrical component of the unbalanced current. The  compensator reduces the negative sequence symmetrical component of the unbalanced current. The positive sequence symmetrical component of the unbalanced current and the scattered current remain uncompensated. It is because shunt reactive compensators do not have any capability for that. Thyristor Switched Inductors (TSIs) enable the susceptance control of the compensator branches, referred to in the article as Thyristor Controlled Susceptance (TCS) branches. Periodic switching of thyristors in these branches causes the generation of harmonic currents, in particular the third-order harmonic. Moreover, in the presence of the supply voltage harmonics, a resonance of the equivalent capacitance of the compensator with the distribution system inductance can occur. These two harmful phenomena in the compensator suggested were reduced by the selection of a special structure of the TCS branches and their LC parameters. The presented method of the adaptive compensator synthesis was verified in the article with a numerical example and results of computer modeling of the load with an adaptive compensator.

[1]  S. Jeon Passive-component-based reactive power compensation in a non-sinusoidal multi-line system , 2020 .

[2]  Leszek S. Czarnecki,et al.  Adaptive Balancing of Three-Phase Loads at Four-Wire Supply with Reactive Compensators and Nonsinusoidal Voltage , 2020, 2020 IEEE Texas Power and Energy Conference (TPEC).

[3]  L. Czarnecki Currents' Physical Components (CPC) - based Power Theory A Review Part I: Power Properties of Electrical Circuits and Systems , 2019, PRZEGLĄD ELEKTROTECHNICZNY.

[4]  Dipten Maiti,et al.  Three‐phase thyristor controlled reactor using two sets of delta connected switches with low current harmonics , 2019, IET Power Electronics.

[5]  Leszek S. Czarnecki,et al.  CPC - Based Reactive Balancing of Linear Loads in Four-Wire Supply Systems with Nonsinusoidal Voltage , 2019, PRZEGLĄD ELEKTROTECHNICZNY.

[6]  L. Czarnecki,et al.  Why the Electric Arc Nonlinearity Improves the Power Factor of Ac Arc Furnaces? , 2018, 2018 IEEE International Conference on Environment and Electrical Engineering and 2018 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe).

[7]  An Luo,et al.  Combined System for Harmonic Suppression and Reactive Power Compensation , 2009, IEEE Transactions on Industrial Electronics.

[8]  M.E. El-Hawary,et al.  Defining Power Components in Nonsinusoidal Unbalanced Polyphase Systems: The Issues , 2008, IEEE Transactions on Power Delivery.

[9]  J. Cohen,et al.  A practical approach to power factor definitions: transmission losses, reactive power compensation, and machine utilization , 2006, 2006 IEEE Power Engineering Society General Meeting.

[10]  M. Chindris,et al.  Steinmetz system design under unbalanced conditions , 2002 .

[11]  L. S. Czarnecki,et al.  Thyristor controlled susceptances for balancing compensators operated under nonsinusoidal conditions , 1994 .

[12]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[13]  R. P. Stratford,et al.  Reactive Compensation and Harmonic Suppression for Industrial Power Systems Using Thyristor Converters , 1976, IEEE Transactions on Industry Applications.

[14]  L. Czarnecki Currents’ Physical Components (CPC)–based Power Theory A Review Part II: Filters and reactive, switching and hybrid compensators , 2020 .

[15]  Michel Malengret,et al.  Active Currents, Power Factor, and Apparent Power for Practical Power Delivery Systems , 2020, IEEE Access.

[16]  Julia Frankfurter,et al.  Reactive Power Control In Electric Systems , 2016 .

[17]  Daniel Mayer,et al.  NEW APPROACH TO SYMMETRIZATION OF THREE-PHASE NETWORK , 2005 .