In vivo evaluation of signal processors for laser Doppler tissue flowmeters

The performance of different signal processors for laser Doppler tissue flowmeters was evaluated by the use of a well defined flow model comprising a segment of the feline intestinal wall. The processor that, apart from being based on the calculation of the first moment of the power spectral density, also takes into account the effect of multiple scattering in a number of blood cells gave an output signal that was linearly related to the intestinal wall perfusion as recorded independently by a drop-counting technique. At a recording bandwidth of 12 kHz, this linear relationship was valid for the entire flow range 0–300 ml min−1 100 g−1 (r=0·98). The processor based on the first moment of the power spectral density alone under-estimated the highest flow rates by about 35 per cent, while within the flow range 0–100 ml min−1 100 g−1 this processor also gave an output signal linearly related to flow at a recording bandwidth of 12 kHz (r=0·96). When the bandwidth was limited to 4 kHz, the output signals from both processors were linearly related to flow only within the range 0–100 ml min−1 100 g−1 (r=0·90). The output signals recorded with the 4 kHz systems were, however, generally only about 65 per cent of those recorded with the 12 kHz systems.

[1]  Gert E. Nilsson,et al.  Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow , 1980, IEEE Transactions on Biomedical Engineering.

[2]  O Lundgren,et al.  Intramural blood flow and blood volume in the small intestine of the cat as analyzed by an indicator-dilution technique. , 1973, Acta physiologica Scandinavica.

[3]  G. Nilsson,et al.  Signal processor for laser Doppler tissue flowmeters , 1984, Medical and Biological Engineering and Computing.

[4]  J Micheels,et al.  Clinical use of laser Doppler flowmetry in a burns unit. , 1984, Scandinavian journal of plastic and reconstructive surgery.

[5]  R. Nossal,et al.  Model for laser Doppler measurements of blood flow in tissue. , 1981, Applied optics.

[6]  C G Ellis,et al.  Simultaneous assessment of red cell perfusion in skeletal muscle by laser Doppler flowmetry and video microscopy. , 1985, International journal of microcirculation, clinical and experimental.

[7]  G. Nilsson,et al.  Assessment of skin irritancy in man by laser Doppler flowmetry , 1982, Contact dermatitis.

[8]  E G Salerud,et al.  Evaluation of laser Doppler flowmetry in the assessment of intestinal blood flow in cat. , 1985, Gastroenterology.

[9]  J Micheels,et al.  Laser doppler flowmetry. A new non-invasive measurement of microcirculation in intensive care? , 1984, Resuscitation.

[10]  Gert E. Nilsson,et al.  A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy , 1980, IEEE Transactions on Biomedical Engineering.

[11]  K Johansson,et al.  Assessment of small-bowel ischemia by laser Doppler flowmetry. Some case reports. , 1986, Scandinavian journal of gastroenterology.

[12]  G. Holloway,et al.  Laser Doppler measurement of cutaneous blood flow. , 1977, The Journal of investigative dermatology.

[13]  H Svensson,et al.  Laser Doppler flowmetry and laser photometry for monitoring free flaps. , 1985, Scandinavian journal of plastic and reconstructive surgery.