The second borehole for the Immobilized Low-Activity Waste Disposal site Performance Assessment (PA) was drilled in March 2001. Continuous core samples were obtained for characterization activities in support of the PA. The borehole was drilled to a depth of 335 feet below ground surface and completed as a groundwater monitoring well. Only sediments of the Hanford formation were penetrated further defining the paleochannel that trends northwest southeast through the 200 East Area. Open-framework gravel was encountered from 335 feet drilled depth to 270 feet. From 270 feet to the surface, sands dominate the stratigraphy with minor amounts of gravel. The stratigraphic section can be divided into three layers defined by paleosols at the top. The water table is at 312.45 feet below ground surface. Aquifer testing indicates that a lower bounding value for hydraulic conductivity of the gravels comprising the paleochannel is 75 m/day.

[1]  K. R. Fecht,et al.  Field trip guide to the Hanford Site , 1992 .

[2]  Bruce N. Bjornstad,et al.  Revised Hydrogeology for the Suprabasalt Aquifer System, 200-East Area and Vicinity, Hanford Site, Washington , 2000 .

[3]  F. A. Spane,et al.  Applicability of Slug Interference Tests for Hydraulic Characterization of Unconfined Aquifers: (2) Field Test Examples , 1996 .

[4]  Paul D. Thorne,et al.  Results of Detailed Hydrologic Characterization Tests - Fiscal Year 2000 , 2001 .

[5]  H. Bouwer The Bouwer and Rice Slug Test — An Updatea , 1989 .

[6]  James J. Butler,et al.  Slug Tests in Unconfined Formations: An Assessment of the Bouwer and Rice Technique , 1995 .

[7]  James J. Butler,et al.  Improving the quality of parameter estimates obtained from slug tests , 1996 .

[8]  F. A. Spane,et al.  DERIV: A Computer Program for Calculating Pressure Derivatives for Use in Hydraulic Test Analysis , 1993 .

[9]  H. Bouwer,et al.  A slug test for determining hydraulic conductivity of unconfined aquifers with completely or partially penetrating wells , 1976 .

[10]  T. Narasimhan,et al.  An Evaluation of the Bouwer and Rice Method of Slug Test Analysis , 1995 .

[11]  Stephen P. Reidel Second ILAW Site Borehole Characterization Plan , 2000 .

[12]  S. P. Reidel,et al.  Immobilized low-activity waste site borehole 299-E17-21 , 1998 .

[13]  F. Spane,et al.  Summary and evaluation of hydraulic property data available for Eielson Air Force Base, Alaska , 1994 .

[14]  K. D. Reynolds,et al.  Characterization plan for the immobilized low-activity waste borehole , 1998 .

[15]  James J. Butler,et al.  Slug tests in partially penetrating wells , 1994 .

[16]  M. J. Fayer,et al.  Recharge Data Package for the Immobilized Low-Activity Waste 2001 Performance Assessment , 1999 .