Simultaneous 99mTc/111In SPECT image reconstruction using convolution based forced detection

Simultaneous multi-isotope SPECT imaging has a number of applications, for example, cardiac, brain and cancer imaging. The major concern in simultaneous multi-isotope is the significant crosstalk contamination between the different isotopes used. The current study focuses on a method of crosstalk compensation between two isotopes in simultaneous dual isotope SPECT acquisition applied to cancer imaging using 99mTc/111In. Monte Carlo (MC), which is thought to offer the most realistic crosstalk and scatter compensation modeling, in typical implementations, has inherent long calculation times (often several hours or days) associated with it. This makes MC unsuitable for clinical applications. We have previously incorporated convolution based forced detection into SIMIND Monte Carlo program which have made MC feasible to use in clinical time frames. In order to evaluate the accuracy of our accelerated MC program a number of point source simulation results were compared to experimentally acquired data in terms of spatial resolution and detector sensitivity. We have developed an iterative MC-based image reconstruction technique that simulates the photon downscatter from one isotope into the acquisition window of a second isotope. The MC based estimation of scatter contamination contained in projection views is then used to compensate for the photon contamination during iterative reconstruction. We use a modified ordered subset-expectation maximization (OS-EM), named as simultaneous ordered subset-expectation maximization (Sim-OSEM), to perform this step. We have undertaken a number of simulation tests and phantom studies to verify this approach. The proposed reconstruction technique also evaluated by reconstruction of experimentally acquired projection phantom data. Reconstruction using Sim-OSEM showed very promising results in terms of crosstalk and scatter compensation and uniformity of background compared to analytical attenuation based reconstruction after triple energy window (TEW) based scatter correction of projection data. In our case images obtained using Sim-OSEM showed better scatter compensation and more uniform background when compared to the images reconstructed for separately acquired projection data using analytical attenuation based reconstruction.

[1]  M. King,et al.  Correction for crosstalk contaminations in dual radionuclide /sup 99m/Tc and /sup 123/I images using artificial neural network , 2004, IEEE Transactions on Nuclear Science.

[2]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[3]  M. King,et al.  Accelerated SPECT Monte Carlo Simulation Using Multiple Projection Sampling and Convolution-Based Forced Detection , 2006, IEEE Transactions on Nuclear Science.

[4]  J. Quintana,et al.  The dual-isotope ProstaScint imaging procedure: clinical experience and staging results in 145 patients. , 2000, Clinical nuclear medicine.

[5]  B.M.W. Tsui,et al.  Validation and evaluation of model-based crosstalk compensation method in simultaneous /sup 99m/Tc stress and /sup 201/Tl rest myocardial perfusion SPECT , 2002, IEEE Transactions on Nuclear Science.

[6]  Eric C. Frey,et al.  A model-based crosstalk compensation method for simultaneous Tl-201 and Tc-99m dual isotope myocardial SPECT imaging , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[7]  Robert E. Zimmerman,et al.  Simultaneous Tc-99m/Tl-201 imaging using energy-based estimation of the spatial distributions of contaminant photons , 1995 .

[8]  Michael A. King,et al.  Correction for Crosstalk Contaminations in Dual Radionuclide and Images Using Artificial Neural Network , 2004 .

[9]  V. Bhadkamkar,et al.  Impact of radioimmunoscintigraphy on the management of colorectal and ovarian cancer patients: a retrospective study. , 1998, Cancer investigation.

[10]  J. Seibyl,et al.  Correction for Cross-talk Contaminations in Dual Radionuclide 99 mTc and 123 I Images Using Artificial Neural Network , 2022 .

[11]  A. Floren,et al.  ' " ' " ' " . " ' " " " " " ' " ' " " " " " : ' " 1 , 2001 .

[12]  Jerry L. Prince,et al.  A vector Wiener filter for dual-radionuclide imaging , 1996, IEEE Trans. Medical Imaging.

[13]  J.S. Lee,et al.  Crosstalk and scatter correction in simultaneous dual isotope SPECT imaging using four energy windows method , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[14]  Scatter correction based on an artificial neural network for99mTc and123I dual-isotope SPECT in myocardial and brain imaging , 2007, Annals of nuclear medicine.

[15]  K. Ogawa,et al.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  Wen-Sheng Huang,et al.  SEPARATION OF TWO RADIONUCLIDES IN SIMULTANEOUS DUAL- ISOTOPE IMAGING WITH INDEPENDENT COMPONENT ANALYSIS , 2006 .

[17]  E. Frey,et al.  dual-isotope simultaneous acquisition brain SPECT , 2009 .