CNMAN: a Chinese adult male voxel phantom constructed from color photographs of a visible anatomical data set.

A voxel phantom of Chinese adult male called CNMAN was constructed from color photographs of the first Chinese visible human data set, for radiation protection purpose. This data set was obtained from a 35-y-old Chinese male cadaver by a medical university in China. The man, 170 cm in height and 65 kg in weight, was dead without any pathological changes. The image size for transversal anatomical photographs of the whole body was 3072 x 2048. After the photographs were semi-automatically segmented, the voxel phantom (CNMAN) with a voxel size of 0.16 mm x 0.16 mm x 1 mm, consisting of 29 tissues or organs was constructed. Combined with the MCNP Monte Carlo transport code, preliminary results for radiation protection dosimetry were obtained based on this Chinese voxel phantom.

[1]  A. Bozkurt,et al.  VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONS , 2000, Health physics.

[2]  Choonsik Lee,et al.  Korean adult male voxel model KORMAN segmented from magnetic resonance images. , 2004, Medical physics.

[3]  Pheng-Ann Heng,et al.  Creation of the Chinese visible human data set. , 2003, Anatomical record. Part B, New anatomist.

[4]  S. Koga,et al.  Japanese adult male voxel phantom constructed on the basis of CT images. , 2007, Radiation protection dosimetry.

[5]  Jai-Ki Lee,et al.  Development of the two Korean adult tomographic computational phantoms for organ dosimetry. , 2006, Medical physics.

[6]  J. W. Vieira,et al.  All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry. , 2003, Physics in medicine and biology.

[7]  G Drexler,et al.  The construction of computer tomographic phantoms and their application in radiology and radiation protection , 1988, Radiation and environmental biophysics.

[8]  N Petoussi-Henss,et al.  ADULT FEMALE VOXEL MODELS OF DIFFERENT STATURE AND PHOTON CONVERSION COEFFICIENTS FOR RADIATION PROTECTION , 2004, Health physics.

[9]  T. Nagaoka,et al.  Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry. , 2004, Physics in medicine and biology.

[10]  P. Heng,et al.  Chinese visible human project , 2006, Clinical anatomy.

[11]  L. Lanzl,et al.  An instrumented phantom system for analog computation of treatment plans. , 1962, The American journal of roentgenology, radium therapy, and nuclear medicine.

[12]  Nina Petoussi-Henss,et al.  The GSF family of voxel phantoms , 2002, Physics in medicine and biology.

[13]  T. Shirotani Realistic torso phantom for calibration of in-vivo transuranic-nuclide counting facilities , 1988 .

[14]  D. J. Brenner Conversion Coefficients for Use in Radiological Protection against External Radiation , 1999 .

[15]  X. Xu,et al.  Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model , 2000, Physics in medicine and biology.

[16]  M Zankl,et al.  Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system , 2001, Radiation and environmental biophysics.

[17]  N Petoussi-Henss,et al.  Organ dose conversion coefficients for external photon irradiation of male and female voxel models , 2002, Physics in medicine and biology.

[18]  X. Xu,et al.  Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-Man tomographic model. , 2001, Health physics.

[19]  A. L. Anderson,et al.  Fabrication of a tissue-equivalent torso phantom for intercalibration of in-vivo transuranic-nuclide counting facilities , 1978 .

[20]  X. Xu,et al.  Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code: internal electron emitters. , 2001, Physics in medicine and biology.

[21]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[22]  Liu Zheng Number one of Chinese digitized visible human completed , 2002 .

[23]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[24]  M. Zankl,et al.  The adult male voxel model ”Golem” segmented from whole-body CT patient data , 2001, Radiation and environmental biophysics.

[25]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  M. Zankl,et al.  Voxel Anthropomorphic Models as a Tool for Internal Dosimetry , 1998 .