Evaluation of image quality of personal ultrasound imager: Comparison with the conventional machine

ObjectiveTo determine if the image quality of a personal ultrasound imager (PUI) is as good as that of a conventional machine (CM).Materials and MethodsNinety patients were studied by the same operator using both the PUI and CM. The quality of the B-mode images obtained from these patients was scored 0, 1 or 2, defined as poor, fair, or good, respectively. Liver-tumor vascularity depicted by power Doppler imaging (PDI) and directional PDI (DPDI) was classified as 0, no blood signal; 1, dot-like blood signal within the tumor; 2, mild blood-flow signal within the tumor; and 3, abundant blood-flow signal within the tumor.ResultsThe mean score of PUI and CM B-mode image quality was 7.47±0.92 and 7.54±0.99 (mean±SD), respectively (p=0.531). On PDI, grade of vascularity of the liver tumors determined with the PUI was 4.44 and 4.68 in those determined with the CM (p=0.78). On DPDI, tumor vascularity was 3.12 when scored by the PUI and 4.29 when scored with the CM (p=0.03). The qualities of images acquired by the PUI and CM were significantly correlated.ConclusionThe quality of B-mode images acquired using the PUI and CM are statistically the same, and they share a similar ability to detect intratumoral blood-flow signals on PDI. Because of its extreme portability, the PUI is expected to become a valuable diagnostic tool in the clinic.

[1]  J M Rubin,et al.  Power Doppler US: a potentially useful alternative to mean frequency-based color Doppler US. , 1994, Radiology.

[2]  Power Doppler Us: A Potentially Useful Alternative to Mean Frequency-Based Color Doppler Us , 1996 .

[3]  M. Makuuchi,et al.  The diagnosis of small hepatocellular carcinomas: efficacy of various imaging procedures in 100 patients. , 1990, AJR. American journal of roentgenology.

[4]  D. Wherry Potential of a Hand-Held Ultrasound in Assessment of the Injured Patient , 1998 .

[5]  O. Matsui,et al.  Benign and malignant nodules in cirrhotic livers: distinction based on blood supply. , 1991, Radiology.

[6]  B. Choi,et al.  Vascularity of hepatocellular carcinoma: assessment with contrast-enhanced second-harmonic versus conventional power Doppler US. , 2000, Radiology.

[7]  Assessment of Tumor Vascularity in Hepatocellular Carcinoma: Comparison of Power Doppler Us and Color Doppler Us , 1997 .

[8]  B. Choi,et al.  Hepatic tumors: contrast agent-enhancement patterns with pulse-inversion harmonic US. , 2000, Radiology.

[9]  A. Joseph,et al.  Comparison of liver histology with ultrasonography in assessing diffuse parenchymal liver disease. , 1991, Clinical radiology.

[10]  Am Pritchett The personal ultrasound imager : extension of the cardiovascular physical examination , 2000 .

[11]  L. Solbiati,et al.  Power Doppler sonography: general principles, clinical applications, and future prospects , 1998, European Radiology.

[12]  B. Choi,et al.  Power versus conventional color Doppler sonography: comparison in the depiction of vasculature in liver tumors. , 1996, Radiology.

[13]  H. Nakase,et al.  Power Doppler imaging of hepatic tumours: Differential diagnosis between hepatocellular carcinoma and metastatic adenocarcinoma , 1998, Journal of gastroenterology and hepatology.

[14]  J. Maxwell,et al.  Comparison of Ultrasound with Liver Histology in Assessing Diffuse Parenchymal Liver Disease , 1988 .

[15]  J. Seward,et al.  Personal ultrasound imager: abdominal aortic aneurysm screening. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.