Free‐breathing inner‐volume black‐blood imaging of the human heart using two‐dimensionally selective local excitation at 3 T

Black‐blood fast spin‐echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold‐over artifacts, using a sufficiently large field of view in phase‐encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner‐volume approach, the combination of a black‐blood fast spin‐echo sequence with a two‐dimensionally selective radiofrequency pulse is proposed for selective “local excitation” small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user‐specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.

[1]  N M Hylton,et al.  Multiple spin-echo magnetic resonance imaging. , 1985, Radiology.

[2]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[3]  René M. Botnar,et al.  3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition , 2001, Magnetic resonance in medicine.

[4]  Gérard Roland Crelier Two-dimensionally selective excitation for cardiovascular magnetic resonance imaging , 1996 .

[5]  R. Ehman,et al.  Retrospective adaptive motion correction for navigator‐gated 3D coronary MR angiography , 2000, Journal of magnetic resonance imaging : JMRI.

[6]  Peter Jezzard,et al.  Selective arterial spin labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two‐dimensional radiofrequency pulses , 2003, Magnetic resonance in medicine.

[7]  E. McVeigh,et al.  Signal-to-noise measurements in magnitude images from NMR phased arrays , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[8]  Onur Afacan,et al.  Basis function cross‐correlations for Robust k‐space sample density compensation, with application to the design of radiofrequency excitations , 2007, Magnetic resonance in medicine.

[9]  D Chien,et al.  Fast selective black blood MR imaging. , 1991, Radiology.

[10]  Douglas C Noll,et al.  Small tip angle three‐dimensional tailored radiofrequency slab‐select pulse for reduced B1 inhomogeneity at 3 T , 2005, Magnetic resonance in medicine.

[11]  Peter Börnert,et al.  RF encoding using a multielement parallel transmit system , 2010, Magnetic resonance in medicine.

[12]  R W Parkey,et al.  Fast short-tau inversion-recovery MR imaging. , 1991, Radiology.

[13]  Ronald N. Bracewell,et al.  The Fourier Transform and Its Applications , 1966 .

[14]  L Kaufman,et al.  Inner volume MR imaging: technical concepts and their application. , 1985, Radiology.

[15]  P. Boesiger,et al.  Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging , 2007, Magnetic resonance in medicine.

[16]  O. Simonetti,et al.  "Black blood" T2-weighted inversion-recovery MR imaging of the heart. , 1996, Radiology.

[17]  Albert Macovski,et al.  A linear class of large-tip-angle selective excitation pulses , 1989 .

[18]  Volker Rasche,et al.  Local excitation black blood imaging at 3T: Application to the carotid artery wall , 2008, Magnetic resonance in medicine.

[19]  P. Storey,et al.  R2* imaging of transfusional iron burden at 3T and comparison with 1.5T , 2007, Journal of magnetic resonance imaging : JMRI.

[20]  Frank J Rybicki,et al.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses. , 2005, Medical physics.

[21]  René M. Botnar,et al.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. , 1999, Circulation.

[22]  Zhi-Pei Liang,et al.  A noniterative method to design large‐tip‐angle multidimensional spatially‐selective radio frequency pulses for parallel transmission , 2007, Magnetic resonance in medicine.

[23]  Robert V Mulkern,et al.  Double inversion black‐blood fast spin‐echo imaging of the human heart: A comparison between 1.5T and 3.0T , 2003, Journal of magnetic resonance imaging : JMRI.

[24]  Albert Macovski,et al.  A k-space analysis of small-tip-angle excitation. 1989. , 2011, Journal of magnetic resonance.

[25]  Chun Yuan,et al.  Improved suppression of plaque‐mimicking artifacts in black‐blood carotid atherosclerosis imaging using a multislice motion‐sensitized driven‐equilibrium (MSDE) turbo spin‐echo (TSE) sequence , 2007, Magnetic resonance in medicine.

[26]  P. Bottomley Spatial Localization in NMR Spectroscopy in Vivo , 1987, Annals of the New York Academy of Sciences.

[27]  M. McConnell,et al.  Prospective navigator correction of image position for coronary MR angiography. , 1997, Radiology.

[28]  Bachir Taouli,et al.  Body and cardiovascular MR imaging at 3.0 T. , 2007, Radiology.

[29]  Matthias Stuber,et al.  Local re‐inversion coronary MR angiography: Arterial spin‐labeling without the need for subtraction , 2008, Journal of magnetic resonance imaging : JMRI.

[30]  Christopher J. Hardy,et al.  Two‐dimensional spatially selective spin inversion and spin‐echo refocusing with a single nuclear magnetic resonance pulse , 1987 .

[31]  Jennifer Keegan,et al.  Volume‐selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement , 2003, Journal of magnetic resonance imaging : JMRI.

[32]  Douglas C Noll,et al.  Fast‐kz three‐dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity , 2006, Magnetic resonance in medicine.

[33]  M. McConnell,et al.  Prospective adaptive navigator correction for breath‐hold MR coronary angiography , 1997, Magnetic resonance in medicine.

[34]  Michael Lustig,et al.  Time‐optimal design for multidimensional and parallel transmit variable‐rate selective excitation , 2009, Magnetic resonance in medicine.

[35]  Johnpauly A k-Space Analysis of Small-Tip-Angle Excitation , 2012 .

[36]  Jennifer Keegan,et al.  3D volume‐selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing , 2005, Journal of magnetic resonance imaging : JMRI.

[37]  D. Feinberg,et al.  GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique , 1991, Magnetic resonance in medicine.