Digital Photoplethysmography for Assessment of Arterial Stiffness: Repeatability and Comparison with Applanation Tonometry

Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV.

[1]  Mohamed Elgendi,et al.  Detection of a and b waves in the acceleration photoplethysmogram , 2014, BioMedical Engineering OnLine.

[2]  J. Bartlett,et al.  Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables , 2008, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[3]  Mandeep Singh,et al.  Feature Extraction from Finger Pulse Profile for High Pitta Detection , 2012 .

[4]  J. Ioannidis,et al.  Trends in Citations to Books on Epidemiological and Statistical Methods in the Biomedical Literature , 2013, PloS one.

[5]  J S Harrell,et al.  Acceleration plethysmography to evaluate aging effect in cardiovascular system. Using new criteria of four wave patterns. , 1996, Medical progress through technology.

[6]  Richard P. Lewis,et al.  REVIEWS OF CONTEMPORARY LABORATORY METHODS , 2005 .

[7]  J. Blacher,et al.  Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients. , 1999, Hypertension.

[8]  Dae-Geun Jang,et al.  A comparison of correction algorithms to pulse parameters for estimation of arterial stiffness , 2010, IEEE 10th INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS.

[9]  T. Kawada,et al.  Utility of second derivative of the finger photoplethysmogram for the estimation of the risk of coronary heart disease in the general population. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[10]  H. Bazett,et al.  AN ANALYSIS OF THE TIME‐RELATIONS OF ELECTROCARDIOGRAMS. , 1997 .

[11]  W. B. Murray,et al.  The peripheral pulse wave: Information overlooked , 1996, Journal of clinical monitoring.

[12]  L. Wurfel Mcdonald S Blood Flow In Arteries Theoretical Experimental And Clinical Principles , 2016 .

[13]  W. Ohley,et al.  Dicrotic notch detection using wavelet transform analysis , 1994, Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  Yasmin,et al.  Similarities and differences between augmentation index and pulse wave velocity in the assessment of arterial stiffness. , 1999, QJM : monthly journal of the Association of Physicians.

[15]  Michael Hession,et al.  Augmentation Index Derived from Peripheral Arterial Tonometry Correlates with Cardiovascular Risk Factors , 2011, Cardiology research and practice.

[16]  P. Chowienczyk,et al.  Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse , 2000, Hypertension.

[17]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[18]  D. Spodick,et al.  Measurement of the left ventricular ejection time by digital plethysmography. , 1971, American Heart Journal.

[19]  Stuart D. Summerhayes Application and Interpretation , 2009 .

[20]  K. Takazawa,et al.  Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. , 1998, Hypertension.

[21]  D. Webb,et al.  Heart rate dependency of pulse pressure amplification and arterial stiffness. , 2002, American journal of hypertension.

[22]  J. Nürnberger,et al.  Augmentation index is associated with cardiovascular risk , 2002, Journal of hypertension.

[23]  A. Struthers,et al.  Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses , 2003, Journal of hypertension.

[24]  Dae-Geun Jang,et al.  Enhancing the Pulse Contour Analysis-Based Arterial Stiffness Estimation Using a Novel Photoplethysmographic Parameter , 2015, IEEE Journal of Biomedical and Health Informatics.

[25]  D. Kass,et al.  Combined Ventricular Systolic and Arterial Stiffening in Patients With Heart Failure and Preserved Ejection Fraction: Implications for Systolic and Diastolic Reserve Limitations , 2003, Circulation.

[26]  L. Portney,et al.  Foundations of Clinical Research: Applications to Practice , 2015 .

[27]  M. Elgendi On the Analysis of Fingertip Photoplethysmogram Signals , 2012, Current cardiology reviews.

[28]  L. Boxt McDonald's blood flow in arteries , 1991, CardioVascular and Interventional Radiology.

[29]  D. Karnad,et al.  Update on the evaluation of a new drug for effects on cardiac repolarization in humans: issues in early drug development , 2010, British journal of pharmacology.

[30]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[31]  Dale Schuurmans,et al.  Detection of a and b waves in the acceleration photoplethysmogram , 2014, Biomedical engineering online.

[32]  Dae-Geun Jang,et al.  A morphological approach to calculation of the second derivative of photoplethysmography , 2010, IEEE 10th INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS.

[33]  H Quan,et al.  Assessing reproducibility by the within-subject coefficient of variation with random effects models. , 1996, Biometrics.

[34]  S. Laurent,et al.  Aortic Stiffness Is an Independent Predictor of Primary Coronary Events in Hypertensive Patients: A Longitudinal Study , 2002, Hypertension.

[35]  P. Chowienczyk,et al.  Vasoactive Drugs Influence Aortic Augmentation Index Independently of Pulse-Wave Velocity in Healthy Men , 2001, Hypertension.

[36]  K. Takazawa,et al.  Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. , 2000, American journal of hypertension.

[37]  A. Weissler,et al.  Relationships between left ventricular ejection time, stroke volume, and heart rate in normal individuals and patients with cardiovascular disease. , 1961, American heart journal.

[38]  Nicholas,et al.  Engineering Advances : New Opportunities for Biomedical Engineers , 2022 .

[39]  Torbjörn Falkmer,et al.  The Case for Using the Repeatability Coefficient When Calculating Test–Retest Reliability , 2013, PloS one.

[40]  I Korhonen,et al.  Photoplethysmography and nociception , 2009, Acta anaesthesiologica Scandinavica.

[41]  Mohamed Elgendi Standard Terminologies for Photoplethysmogram Signals , 2012, Current cardiology reviews.

[42]  J. Vestbo,et al.  The association between aortic augmentation index and cardiovascular risk factors in a large unselected population , 2012, Journal of Human Hypertension.

[43]  Kwang Suk Park,et al.  Second Derivative of Photoplethysmography for Estimating Vascular Aging , 2007, 2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine.

[44]  P. Chowienczyk,et al.  Contour analysis of the photoplethysmographic pulse measured at the finger , 2006, Journal of hypertension.

[45]  I. Imanaga,et al.  Correlation between wave components of the second derivative of plethysmogram and arterial distensibility. , 1998, Japanese heart journal.

[46]  T. Ohkubo,et al.  Pulse wave velocity and the second derivative of the finger photoplethysmogram in treated hypertensive patients: their relationship and associating factors , 2002, Journal of hypertension.

[47]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[48]  P. Chowienczyk,et al.  Determination of age-related increases in large artery stiffness by digital pulse contour analysis. , 2002, Clinical science.

[49]  W. Nichols Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms. , 2005, American journal of hypertension.

[50]  M. Saishin,et al.  Left ventricular ejection time measured by finger-tip plethysmography in healthy young Japanese. Its correction for heart rate. , 1975, Japanese circulation journal.

[51]  H. Struijker‐Boudier,et al.  Expert consensus document on arterial stiffness: methodological issues and clinical applications. , 2006, European heart journal.

[52]  J. C. Dorlas,et al.  Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation. , 1985, British journal of anaesthesia.

[53]  A. Avolio The finger volume pulse and assessment of arterial properties. , 2002, Journal of hypertension.

[54]  L. Portney,et al.  Foundations of Clinical Research , 1993 .