Full-Scale Pseudodynamic Testing of Self-Centering Steel Plate Shear Walls

AbstractThis paper presents the first full-scale experimental investigation of the self-centering steel plate shear wall (SC-SPSW) system. The SC-SPSW system is a lateral force-resisting system developed to provide system recentering and limit structural damage to easily replaceable energy dissipating fuses (i.e., thin steel web plates). Recentering is provided by posttensioned (PT) beam-to-column connections. This test program is composed of two two-story SC-SPSW specimens, each with a different PT beam-to-column connection. For one specimen, connections rock about both beam flanges; for the other, connections rock about the top beam flange only. Both specimens incorporated a posttensioned column base detail to further promote recentering and damage mitigation. The specimens were tested pseudodynamically using excitations representing three different seismic hazard levels. Results show that the SC-SPSW system is capable of meeting and exceeding the specified performance objectives.

[1]  A. Nicknam Seismic Design and Testing of Propped Rocking Wall Systems , 2012 .

[2]  Michel Bruneau,et al.  Behavior of Self-Centering Steel Plate Shear Walls and Design Considerations , 2012 .

[3]  Michel Bruneau,et al.  NewZ-BREAKSS: Post-tensioned Rocking Connection Detail Free of Beam Growth , 2011 .

[4]  B. Riley,et al.  EMERGENCY MANAGEMENT AGENCY , 2009 .

[5]  Michel Bruneau,et al.  Full-scale testing of self-centering steel plate shear walls , 2013 .

[6]  Richard Sause,et al.  Experimental studies of full-scale posttensioned steel connections , 2005 .

[7]  A. Patz Experimental studies. , 1955, American journal of ophthalmology.

[8]  Roberto Villaverde,et al.  Fundamental Concepts of Earthquake Engineering , 2009 .

[9]  Jeffrey W. Berman,et al.  Subassembly testing and modeling of self-centering steel plate shear walls , 2013 .

[10]  Nathan M. Newmark,et al.  A Method of Computation for Structural Dynamics , 1959 .

[11]  Patricia Marie Clayton Self-Centering Steel Plate Shear Walls: Subassembly and Full-Scale Testing , 2014 .

[12]  Laura N. Lowes,et al.  Fragility Functions for Steel Plate Shear Walls , 2012 .

[13]  Gregory A. MacRae,et al.  Development of the self-centering Sliding Hinge Joint with friction ring springs , 2012 .

[14]  Jeffrey W. Berman,et al.  Seismic Design and Performance of Self-Centering Steel Plate Shear Walls , 2012 .

[15]  Gregory A. MacRae,et al.  Some recent New Zealand research on seismic steel structures , 2009 .

[16]  Hassan Moghimi,et al.  Beam Design Force Demands in Steel Plate Shear Walls with Simple Boundary Frame Connections , 2014 .

[17]  Jeffrey W. Berman,et al.  Experimental Investigation of Self-Centering Steel Plate Shear Walls , 2012 .

[18]  Hoseok Chi,et al.  Seismic behavior of post-tensioned column base for steel self-centering moment resisting frame , 2012 .

[19]  Keh-Chyuan Tsai,et al.  Seismic design and testing of the bottom vertical boundary elements in steel plate shear walls. Part 2: experimental studies , 2014 .

[20]  Xxyyzz,et al.  Minimum Design Loads for Buildings and Other Structures , 1990 .

[21]  John B. Mander,et al.  Damage Avoidance Design Steel Beam-Column Moment Connection Using High-Force-to-Volume Dissipators , 2009 .

[22]  Andre Filiatrault,et al.  Posttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames , 2002 .