In vivo measurement of shoulder joint loads during activities of daily living.

Until recently the contact loads acting in the glenohumeral joint have been calculated using musculoskeletal models or measured in vitro. Now, contact forces and moments are measured in vivo using telemeterized shoulder implants. Mean total contact forces from four patients during eight activities of daily living are reported here. Lifting a coffee pot (1.5kg) with straight arm caused an average force of 105.0%BW (%body weight) (range: 90-124.6%BW), while setting down the coffee pot in the same position led to higher forces of 122.9%BW on the average (105.3-153.4%BW). The highest joint contact forces were measured when the straight arm was abducted or elevated by 90 degrees or more, with a weight in the hand. Lifting up 2kg from a board up to head height caused a contact force of 98.3%BW (93-103.6%BW); again, setting it down on the board led to higher forces of 131.5%BW (118.8-144.1%BW). In contrast to previously calculated high loads, the contact force during passive holding of a 10kg weight laterally was only 12.3%BW (9.2-17.9%BW), but when lifting it up to belt height it increased to 91.5%BW (87-95%BW). The moments transferred inside the joint at our patients varied much more than did the forces both inter and intra-individually. Our data suggest that patients with shoulder problems or during the first post-operative weeks after shoulder fractures or joint replacements should avoid certain activities encountered during daily living e.g. lifting or holding a weight with an outstretched arm. Some energy-related optimization criteria used in the literature for analytical musculoskeletal shoulder models must now be reconsidered.

[1]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[2]  Antonius Rohlmann,et al.  LOADING OF THE GLENOHUMERAL JOINT DURING EVERYDAY LIFE , 2008 .

[3]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[4]  A Terrier,et al.  Simulated joint and muscle forces in reversed and anatomic shoulder prostheses. , 2008, The Journal of bone and joint surgery. British volume.

[5]  F C T van der Helm,et al.  A kinematical analysis of the shoulder after arthroplasty during a hair combing task. , 2006, Clinical biomechanics.

[6]  A Rohlmann,et al.  An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint. , 2009, Medical engineering & physics.

[7]  E A Audenaert,et al.  Shoulder prostheses treating cuff tear arthropathy: A comparative biomechanical study , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  Philippe Favre,et al.  An algorithm for estimation of shoulder muscle forces for clinical use. , 2005, Clinical biomechanics.

[9]  F. Kummer,et al.  Development of a Telemeterized Shoulder Prosthesis , 1996, Clinical orthopaedics and related research.

[10]  Michael Damsgaard,et al.  COMPARISON OF A MUSCULOSKELETAL SHOULDER MODEL WITH IN-VIVO JOINT FORCES , 2007 .

[11]  H. E. J. Veeger,et al.  Toward standardized procedures for recording and describing 3-D shoulder movements , 2003, Behavior research methods, instruments, & computers : a journal of the Psychonomic Society, Inc.

[12]  D R Pichora,et al.  Glenohumeral contact forces , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[13]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[14]  A R Karduna,et al.  Total shoulder arthroplasty biomechanics: a study of the forces and strains at the glenoid component. , 1998, Journal of biomechanical engineering.

[15]  A Rohlmann,et al.  In vivo glenohumeral contact forces--measurements in the first patient 7 months postoperatively. , 2007, Journal of biomechanics.

[16]  F. V. D. van der Helm Analysis of the kinematic and dynamic behavior of the shoulder mechanism. , 1994, Journal of biomechanics.

[17]  G Bergmann,et al.  Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb. , 2003, Journal of biomechanics.

[18]  Poppen Nk,et al.  Forces at the glenohumeral joint in abduction. , 1978 .

[19]  N. Poppen,et al.  Forces at the glenohumeral joint in abduction. , 1978, Clinical orthopaedics and related research.

[20]  Jaap Harlaar,et al.  Complete 3D kinematics of upper extremity functional tasks. , 2008, Gait & posture.

[21]  M. O. Hellera,et al.  Musculo-skeletal loading conditions at the hip during walking and stair climbing , 2001 .

[22]  Antonius Rohlmann,et al.  Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants , 2007, IEEE Transactions on Biomedical Engineering.