Modeling evaluation of a direct-expansion solar-assisted heat pump water heater using R410A.

A direct-expansion solar-assisted heat pump (DX-SAHP) system by using R410A as refrigerant is described, which can supply domestic hot water during the whole year. Based on the distributed parameter and homogeneous flow models of collector/evaporator and condenser, the lumped parameter models of compressor and electronic expansion valve, and the refrigerant charge model, a numerical model is developed to estimate the thermal performance of the system. Given the structure parameters, meteorological parameters, initial and final water temperatures, for a fixed superheat degree, the effects of the refrigerant charge quantity on the performance parameters of the system are analyzed, such as compressor power, heat gain of collector, heating time, collector efficiency and system COP. Furthermore, for a fixed refrigerant charge quantity, the effects of various parameters, including solar radiation, ambient temperature, compressor speed and initial water temperature, have been simulated and analyzed on the thermal performance of the system.

[1]  Min-Soo Kim,et al.  Comparison of the heating performance of an inverter-driven heat pump system using R410A vapor-injection into accumulator and compressor. , 2012 .

[2]  M. Picon Nunez,et al.  Exergy analysis and optimization of a solar-assisted heat pump , 1998 .

[3]  Bin-Juine Huang,et al.  Performance characteristics of integral type solar-assisted heat pump , 2001 .

[4]  M. Ally,et al.  Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in a low-energy test house under simulated occupancy conditions , 2012 .

[5]  Guoliang Ding,et al.  Experimental validation of void fraction models for R410A air conditioners , 2009 .

[6]  Bu-Xuan Wang,et al.  Experimental investigation of condensation heat transfer and pressure drop of R22, R410A and R407C in mini-tubes , 2012 .

[7]  Ruzhu Wang,et al.  Experimental performance analysis and optimization of a direct expansion solar-assisted heat pump water heater , 2007 .

[8]  F. D. Monte Calculation of thermodynamic properties of R407C and R410A by the Martin-Hou equation of state. Part II. Technical interpretation. , 2002 .

[9]  E. Elgendy,et al.  Modelling and validation of a gas engine heat pump working with R410A for cooling applications , 2011 .

[10]  Reinhard Radermacher,et al.  Two-stage heat pump system with vapor-injected scroll compressor using R410A as a refrigerant , 2009 .

[11]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[12]  Evyatar Erell,et al.  Radiative cooling of buildings with flat-plate solar collectors , 2000 .

[13]  Ruzhu Wang,et al.  Performance of a multi-functional direct-expansion solar assisted heat pump system , 2006 .

[14]  K. F. Fong,et al.  Modeling and application of direct-expansion solar-assisted heat pump for water heating in subtropical Hong Kong , 2010 .

[15]  Sadasuke Ito,et al.  Studies of Radiative Cooling Systems for Storing Thermal Energy , 1989 .

[16]  Bin-Juine Huang,et al.  Long-term performance of solar-assisted heat pump water heater , 2004 .

[17]  Liao Sheng-ming Theoretic and experimental study on domestic air-conditioner with R410A as refrigerant , 2010 .

[18]  Hoon Kang,et al.  Performance comparison between a single-stage and a cascade multi-functional heat pump for both air heating and hot water supply. , 2013 .

[19]  Predrag Stojan Hrnjak,et al.  Experimental and numerical study on microchannel and round-tube condensers in a R410A residential air-conditioning system , 2008 .

[20]  J. M. Calm,et al.  Refrigerant Data Summary , 2001 .

[21]  M. Izquierdo,et al.  Theoretical model and experimental validation of a direct-expansion solar assisted heat pump for domestic hot water applications , 2012 .

[22]  José Fernández-Seara,et al.  Experimental analysis of a direct expansion solar assisted heat pump with integral storage tank for domestic water heating under zero solar radiation conditions , 2012 .

[23]  Bin-Juine Huang,et al.  Performance evaluation method of solar-assisted heat pump water heater , 2007 .

[24]  E. Elgendy,et al.  Performance of a gas engine heat pump (GEHP) using R410A for heating and cooling applications , 2010 .

[25]  C. Son,et al.  Condensation pressure drop of R22, R134a and R410A in a single circular microtube , 2012 .

[26]  Ruzhu Wang,et al.  Experimental performance analysis on a direct-expansion solar-assisted heat pump water heater , 2007 .

[27]  Tarek Abdel-Salam,et al.  Two-stage direct expansion solar-assisted heat pump for high temperature applications , 2009 .

[28]  S. Ito,et al.  PERFORMANCE OF A HEAT PUMP USING DIRECT EXPANSION SOLAR COLLECTORS 1 Paper presented at the ISES Sol , 1999 .

[29]  W. Chen,et al.  A comparative study on the performance and environmental characteristics of R410A and R22 residential air conditioners , 2008 .

[30]  Arif Hepbasli,et al.  Exergetic assessment of direct-expansion solar-assisted heat pump systems: Review and modeling , 2008 .