Increasing the transmitted flow pulse in a rotary left ventricular assist device.

Long-term rotary left ventricular assist devices (LVADs) are increasingly employed to bridge patients with end-stage heart failure to transplant or as a destination therapy. Significant recent device development has increased patient support times, shifting further development focus toward physiologically sensitive control of the pump operation. Sensorless control of these devices would benefit from increased observability of the ventricular volume/preload to the pump, in order to regulate flow based on preload, imitating the native Frank-Starling flow control. Monitoring the transmitted flow pulse through the pump has been used as a surrogate for preload, although means of maximizing its transmission are not clear. However, it is known that a flat hydraulic performance curve of the rotary pump induces high changes in flow for a given change in pressure head. The aim of this study was to determine geometric pump parameters responsible for increasing this flow pulse transmission and to demonstrate this increase in vitro. The sensitivity of the performance gradient to blade angles, blade heights, blade clearance, and channel areas were studied. Resulting pressure head, flow, and hydraulic efficiency were analyzed with respect to textbook designed procedures. Then pumps with comparably "flat" and "steep" performance curves were used to simulate LVAD support in vitro over a range of pump flow rates to observe the transmitted flow pulsatility. It was found that an outlet blade angle of 90°, inlet blade angle between 25 and 45°, and large throat area generated a "flatter" performance curve. The transmitted flow pulsatility through a pump with a flat performance curve was 68% higher than that of a steep performance curve at a flow rate of 5 L/min. Substantial gains in the observability of LVAD preload/resident blood volume in the ventricle exist through the careful selection of specific pump geometries.

[1]  H. N. Michael Centrifugal and axial flow pumps: by A. J. Stepanoff. 428 pages, illustrations, diagrams, 15 × 24 cm. New York, John Wiley & Sons, Inc., 1948. Price, $7.50 , 1948 .

[2]  L Xu,et al.  System analysis of the flow/pressure response of rotodynamic blood pumps. , 1999, Artificial organs.

[3]  M B Visscher,et al.  The regulation of the energy output of the heart , 1927, The Journal of physiology.

[4]  David Japikse,et al.  Centrifugal pump design and performance , 1997 .

[5]  A.J.Stepanoff Centrifugal and Axial Flow Pumps: Design and Application , 1957 .

[6]  O. E. Baljé,et al.  Turbomachines—A Guide to Design Selection and Theory , 1981 .

[7]  M A Griffin,et al.  Left ventricular assist devices. , 1998, RN.

[8]  J F Antaki,et al.  Effect of pressure-flow relationship of centrifugal pump on in vivo hemodynamics: a consideration for design. , 1998, Artificial organs.

[9]  E. Birks Left ventricular assist devices , 2009, Heart.

[10]  J. Maessen,et al.  Suction due to left ventricular assist: implications for device control and management. , 2007, Artificial organs.

[11]  T. Lüscher,et al.  Pulsatile Stretch Stimulates Superoxide Production and Activates Nuclear Factor-κB in Human Coronary Smooth Muscle , 1997 .

[12]  Y Sezai,et al.  Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. , 1999, Artificial organs.

[13]  H Reul,et al.  Collected Nondimensional Performance of Rotary Dynamic Blood Pumps , 2004, ASAIO journal.

[14]  Jong-Chul Park,et al.  Enhanced chondrogenic responses of human articular chondrocytes onto silk fibroin/wool keratose scaffolds treated with microwave-induced argon plasma. , 2010, Artificial organs.

[15]  G. Giridharan,et al.  Quantification of Pulsatility as a Function of Vascular Input Impedance: An In Vitro Study , 2007, ASAIO journal.

[16]  Daniel Tamez,et al.  Design concepts and principle of operation of the HeartWare ventricular assist system. , 2010, ASAIO journal.

[17]  S. Russell,et al.  Advanced heart failure treated with continuous-flow left ventricular assist device. , 2009, The New England journal of medicine.

[18]  Nicholas Richard Gaddum,et al.  Optimizing the response from a passively controlled biventricular assist device. , 2010, Artificial organs.

[19]  Nigel H Lovell,et al.  Identification and classification of physiologically significant pumping states in an implantable rotary blood pump. , 2006, Artificial organs.

[20]  N H Lovell,et al.  Sensorless flow and head estimation in the VentrAssist rotary blood pump. , 2000, Artificial organs.

[21]  Ulrich Steinseifer,et al.  A compact mock circulation loop for the in vitro testing of cardiovascular devices. , 2010, Artificial organs.