Cantilever beam temperature sensors for biological applications

This review presents two types of cantilever beams employed as highly sensitive temperature sensors. One type is fabricated from composite materials and is operated in the deflection mode. The second type, used as a temperature sensor and presented in this review, is a resonant cantilever beam. The materials used for the fabrication of the bimaterial cantilever beam are silicon or silicon nitride and thin metallic films such as gold or aluminum. When the temperature changes, the different coefficients of thermal expansion of the metal and silicon cause the sensor to deflect. Considering the models of temperature measurement for biological cells, the heat should be applied locally at the tip of the cantilever beam. Formulas for the calculation of the deflection as a function of incident power applied at the free end of the cantilever beam operated in a liquid are presented in this review. The natural convective heat transfer coefficient was estimated by using the mathematical model and experimental values. For biological applications, the cantilever beam temperature sensor was operated in a liquid, and the heat transfer coefficients were between 381 and 642 W/m2K when the temperature applied to the cantilever's free end varied from 28 to 71.8 °C. The resonant cantilever beam was also demonstrated as a sensitive temperature sensor for biological applications. As a thermogenic sample, brown fat cells (BFCs), which are related to metabolic heat production, are employed. The working principle of the resonator cantilever beam temperature sensor is based on the shift in resonant frequency in response to temperature changes. The resonant frequency and the temperature coefficient were 960 kHz and 22.0 ppm/K, respectively. The measurements were performed by stimulating the activity of BFCs by flowing a norepinephrine (NE) solution (1 µM).

[1]  Takahito Ono,et al.  Highly sensitive thermometer using a vacuum-packed Si resonator in a microfluidic chip for the thermal measurement of single cells. , 2016, Lab on a chip.

[2]  Takahito Ono,et al.  Investigation of bimaterial cantilever beam for heat sensing in liquid , 2016 .

[3]  T. Ono,et al.  Bimaterial Nanocantilever Beam Calorimeter for Atmospheric Pressure and Liquid Applications , 2016 .

[4]  Fumihito Arai,et al.  Temperature changes in brown adipocytes detected with a bimaterial microcantilever. , 2014, Biophysical Journal.

[5]  Takahito Ono,et al.  Pico calorimeter for detection of heat produced in an individual brown fat cell , 2012 .

[6]  Subra Suresh,et al.  Measuring single-cell density , 2011, Proceedings of the National Academy of Sciences.

[7]  Takahito Ono,et al.  Evaluation of bimaterial cantilever beam for heat sensing at atmospheric pressure. , 2010, The Review of scientific instruments.

[8]  Rachel A. McKendry,et al.  Physics of Nanomechanical Biosensing on Cantilever Arrays , 2008 .

[9]  Gang Chen,et al.  Thermal conductance of bimaterial microcantilevers , 2008 .

[10]  Debjyoti Banerjee,et al.  Detection of explosives using heated microcantilever sensors , 2006, SPIE Defense + Commercial Sensing.

[11]  Thomas Thundat,et al.  Photothermal spectroscopy of Bacillus anthracis and Bacillus cereus with microcantilevers , 2006 .

[12]  Martin Hegner,et al.  Cantilever array sensors , 2005 .

[13]  M. Sepaniak,et al.  Cantilever transducers as a platform for chemical and biological sensors , 2004 .

[14]  J. Corbeil,et al.  IR imaging using uncooled microcantilever detectors. , 2003, Ultramicroscopy.

[15]  N. Lavrik,et al.  Detection and differentiation of biological species using microcalorimetric spectroscopy. , 2003, Ultramicroscopy.

[16]  Nickolay V Lavrik,et al.  Detection of anthrax simulants with microcalorimetric spectroscopy: Bacillus subtilis and Bacillus cereus spores. , 2003, Applied optics.

[17]  M. Grattarola,et al.  Micromechanical cantilever-based biosensors , 2001 .

[18]  A. Majumdar,et al.  Infrared vision using uncooled micro-optomechanical camera , 1999 .

[19]  Panos G. Datskos,et al.  Photoinduced and thermal stress in silicon microcantilevers , 1998 .

[20]  Arun Majumdar,et al.  Photothermal measurements at picowatt resolution using uncooled micro-optomechanical sensors , 1997 .

[21]  Arun Majumdar,et al.  Optimization and performance of high-resolution micro-optomechanical thermal sensors , 1997 .

[22]  Panos G. Datskos,et al.  Uncooled thermal imaging using a piezoresistive microcantilever , 1996 .

[23]  Panos G. Datskos,et al.  Remote infrared radiation detection using piezoresistive microcantilevers , 1996 .

[24]  James K. Gimzewski,et al.  A femtojoule calorimeter using micromechanical sensors , 1994 .

[25]  J. K. Gimzewski,et al.  Photothermal spectroscopy with femtojoule sensitivity using a micromechanical device , 1994, Nature.

[26]  James K. Gimzewski,et al.  Observation of a chemical reaction using a micromechanical sensor , 1994 .

[27]  N. Rothwell,et al.  Influence of environmental temperature on energy balance, diet-induced thermogenesis and brown fat activity in ‘cafeteria’-fed rats , 1986, British Journal of Nutrition.

[28]  D. Clark,et al.  Microcalorimetric measurements of heat production in brown adipocytes from control and cafeteria-fed rats. , 1986, The Biochemical journal.

[29]  O. Lindberg,et al.  Microcalorimetry of isolated mammalian cells , 1977, Nature.

[30]  G. Stoney The Tension of Metallic Films Deposited by Electrolysis , 1909 .

[31]  S. Rajic,et al.  Fabrication of quantum well microcantilever photon detectors. , 2001, Ultramicroscopy.

[32]  T Yahata,et al.  Influence of endocrine and chemical factors on glucagon induced thermogenesis in brown adipocytes. , 1982, The Japanese journal of physiology.

[33]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[34]  B Pettersson,et al.  CO2-mediated control of fatty acid metabolism in isolated hamster brown-fat cells during norepinephrine stimulation. , 1977, European journal of biochemistry.